The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Minimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles
Open accessAbstract
BACKGROUND: Microneedles have previously been used to deliver insulin to animal models, but not in human subjects. This study tested the hypothesis that hollow microneedles can deliver insulin to modulate blood glucose levels in subjects with type 1 diabetes in a minimally invasive manner. METHODS: This study was carried out in two adults with type 1 diabetes and evaluated bolus delivery of lispro insulin using a hollow microneedle compared to a catheter infusion set (9 mm). The study first determined the minimum insulin delivery depth by administering insulin from microneedles inserted 1, 3.5, and 5 mm into the skin of fasting subjects and then assessed the efficacy of insulin delivery from microneedles inserted 1 mm into the skin to reduce postprandial glucose levels. Blood samples were periodically assayed for plasma free insulin and plasma glucose levels for up to 3.5 h. RESULTS: The first phase of the study indicated that microneedles inserted at the shallowest depth of 1 mm within the skin led to rapid insulin absorption and reduction in glucose levels. Bolus insulin delivery followed by consumption of a standardized meal in the second phase revealed that microneedles were effective in reducing postprandial glucose levels. Subjects reported no pain from microneedle treatments, and there were no adverse events. CONCLUSIONS: This study provides the first proof of concept that hollow microneedles can effectively deliver bolus insulin to type 1 diabetes subjects in a minimally invasive manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Self-citationSilicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Holland, D., Booy, R., Looze, F. D., Eizenberg, P., McDonald, J., Karrasch, J., McKeirnan, M., Salem, H., Mills, G., Reid, J., et al. (2008) · The Journal of Infectious Diseases · doi:10.1086/590434 · Cited by 254
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Self-citationLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Emerging micro- and nanotechnology based synthetic approaches for insulin delivery
Mo, R., Jiang, T., Di, J., Tai, W., & Gu, Z. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60436e · Cited by 386
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
Self-citationAdvances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
Metadata
- Authors
- Gupta, J., Felner, E. I., & Prausnitz, M. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2009-06
- Volume
- 11
- Issue
- 6
- Pages
- 329-337
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1981357012
- Cited by
- 209
- References
- 3
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles. https://app.cochat.ai/papers/10.1089/dia.2008.0103
- The paper
- Gupta, J., Felner, E. I., & Prausnitz, M. R. (2009). Minimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2008.0103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.