Routine Sensor-Augmented Pump Therapy in Type 1 Diabetes: The INTERPRET Study
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Sensor-augmented pump (SAP) therapy can improve glycemic control, compared with multiple daily insulin injections or with insulin pump therapy alone, without increasing the risk of hypoglycemia. SUBJECTS AND METHODS: A 12-month observational study in patients with type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII), upon the introduction of continuous glucose monitoring (CGM), was conducted in 15 countries (in Europe and in Israel) to document the real-life use of SAP and assess which variables are associated with improvement in type 1 diabetes management. RESULTS: Data from 263 patients (38% male; mean age, 28.0 ± 15.7 years [range, 1-69 years]; body mass index, 23.3 ± 4.9 kg/m(2); diabetes duration, 13.9 ± 10.7 years; CSII duration, 2.6 ± 3 years) were collected. Baseline mean glycated hemoglobin A1c (HbA1c) was 8.1 ± 1.4%; 82% had suboptimal HbA1c (≥ 7%). The average sensor use for 12 months was 30% (range, 0-94%), and sensor use decreased with time (first 3 months, 37%; last 3 months, 27%). Factors associated with improvement in HbA1c after 12 months in patients with baseline HbA1c ≥ 7% were high baseline HbA1c (P<0.001), older age group (P<0.001), and more frequent sensor use (P = 0.047). Significantly less hospitalization, increased treatment satisfaction, and reduced fear of hypoglycemia were reported after 12 months of SAP. CONCLUSIONS: This is the largest and longest multicenter prospective observational study providing real-life data on SAP. These results are consistent with those of controlled trials showing the effectiveness of CGM in pump users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Psychometric properties of the hypoglycemia fear survey-ii for adults with type 1 diabetes
Gonder-Frederick, L. A., Schmidt, K. M., Vajda, K. A., Greear, M. L., Singh, H., Shepard, J. A., & Cox, D. J. (2011) · Diabetes Care · doi:10.2337/dc10-1343 · Cited by 337 · cited 1×
“…Satisfaction Questionnaires Status and Change versions (DTSQs and DTSQc, respectively) 16,17 and Hypo-glycemia Fear Survey-II (HFS) questionnaires 18 were administered to adults in Danish, Hungarian, and Spanish centers only, where validated translated versions of the questionnaires were…”
Garg, S., Brazg, R. L., Bailey, T. S., Buckingham, B. A., Slover, R. H., Klonoff, D. C., Shin, J., Welsh, J. B., & Kaufman, F. R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0292 · Cited by 138
Blevins, T. C., Bode, B. W., Garg, S. K., Grunberger, G., Hirsch, I. B., Jovanovič, L., Nardacci, E., Orzeck, E. A., Roberts, V. L., & Tamborlane, W. V. (2010) · Endocrine Practice · doi:10.4158/ep.16.5.730 · Cited by 98
Joubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70 · cited 1×
“24 We believe that the understanding and interpretation of data from CGM and the relevance of therapeutic interventions are all key elements for the effectiveness of SAP.”
Cited by
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Charleer, S., Mathieu, C., Nobels, F., De Block, C., Radermecker, R. P., Hermans, M. P., Taes, Y., Vercammen, C., T'Sjoen, G., Crenier, L., et al. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-02498 · Cited by 196
Optimal use of diabetes devices: clinician perspectives on barriers and adherence to device use
Tanenbaum, M. L., Adams, R. N., Hanes, S. J., Barley, R. C., Miller, K. M., Mulvaney, S. A., & Hood, K. K. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816688010 · Cited by 117
Tumminia, A., Crimi, S., Sciacca, L., Buscema, M., Frittitta, L., Squatrito, S., Vigneri, R., & Tomaselli, L. (2015) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2557 · Cited by 100
Metadata
- Authors
- Nørgaard, K., Scaramuzza, A., Bratina, N., Lalić, N. M., Jarosz-Chobot, P., Kocsis, G., Jasinskiene, E., De Block, C., Carrette, O., Castañeda, J., & Cohen, F. T. I. S. G.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2013-04
- Volume
- 15
- Issue
- 4
- Pages
- 273-280
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2031432201
- Cited by
- 107
- References
- 10
- FWCI
- 10.85
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Routine Sensor-Augmented Pump Therapy in Type 1 Diabetes: The INTERPRET Study. https://app.cochat.ai/papers/10.1089/dia.2012.0288
- The paper
- Nørgaard, K., Scaramuzza, A., Bratina, N., Lalić, N. M., Jarosz-Chobot, P., Kocsis, G., Jasinskiene, E., De Block, C., Carrette, O., Castañeda, J., & Cohen, F. T. I. S. G. (2013). Routine Sensor-Augmented Pump Therapy in Type 1 Diabetes: The INTERPRET Study. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2012.0288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.