CoChat

Hypoglycemia Reduction and Changes in Hemoglobin A1c in the ASPIRE In-Home Study

Open access
Weiss, Ram, Garg, Satish K., Bode, Bruce W., Bailey, Timothy S., Ahmann, Andrew J., Schultz, Kenneth A., Welsh, John B., Shin, John J., for the ASPIRE In-Home Study Group · 2015 · Diabetes Technology & Therapeutics
Cited by 56

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: ASPIRE In-Home randomized 247 subjects with type 1 diabetes to sensor-augmented pump therapy with or without the Threshold Suspend (TS) feature, which interrupts insulin delivery at a preset sensor glucose value. We studied the effects of TS on nocturnal hypoglycemia (NH) in relation to baseline hemoglobin A1c (A1C) and change in A1C during the study. MATERIALS AND METHODS: NH event rates and mean area under curve (AUC) of NH events were evaluated at different levels of baseline A1C (<7%, 7-8%, and >8%) and at different levels of changes in A1C (less than -0.3% [decreased], -0.3% to 0.3% [stable], and >0.3% [increased]), in the TS Group compared with the Control Group (sensor-augmented pump only). RESULTS: In the TS Group, 27.9% of the NH events were accompanied by a confirmatory blood glucose value, compared with 39.3% in the Control Group. Among subjects with baseline A1C levels of <7% or 7-8%, those in the TS Group had significantly lower NH event rates than those in the Control Group (P=0.001 and P=0.004, respectively). Among subjects with decreased or stable A1C levels, those in the TS Group had significantly lower NH event rates, and the events had lower AUCs (P≤0.001 for each). Among subjects with increased A1C levels, those in the TS Group had NH events with significantly lower AUCs (P<0.001). CONCLUSIONS: Use of the TS feature was associated with decreases in the rate and severity (as measured by AUC) of NH events in many subjects, including those with low baseline A1C levels and those whose A1C values decreased during the study period. Use of the TS feature can help protect against hypoglycemia in those wishing to intensify diabetes management to achieve target glucose levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2014.0306

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Weiss, R., Garg, S. K., Bode, B. W., Bailey, T. S., Ahmann, A. J., Schultz, K. A., Welsh, J. B., Shin, J. J., & for the ASPIRE In-Home Study Group
Venue
Diabetes Technology & Therapeutics
Published
2015-08
Volume
17
Issue
8
Pages
542-547
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2444667591
Cited by
56
References
11
FWCI
6.58
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.