A Minority of Patients with Type 1 Diabetes Routinely Downloads and Retrospectively Reviews Device Data
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND: In type 1 diabetes (T1D), periodic review of blood glucose and insulin dosing should be performed, but it is not known how often patients review these data on their own. We describe the proportion of patients with T1D who routinely downloaded and reviewed their data at home. MATERIALS AND METHODS: A cross-sectional survey of 155 adults and 185 caregivers of children with T1D at a single academic institution was performed. "Routine Downloaders" (downloaded four or more times in the past year) were also considered "Routine Reviewers" if they reviewed their data most of the time they downloaded from devices. Logistic regression was used to identify factors associated with being a Routine Reviewer. RESULTS: Only 31% of adults and 56% of caregivers reported ever downloading data from one or more devices, whereas 20% and 40%, respectively, were considered Routine Downloaders. Only 12% of adults and 27% of caregivers were Routine Reviewers. Mean hemoglobin A1c was lower in Routine Reviewers compared with non-Routine Reviewers (7.2±1.0% vs. 8.1±1.6% [P=0.03] in adults and 7.8±1.4% vs. 8.6±1.7% [P=0.001] in children). In adjusted analysis of adults, the odds ratio of being a Routine Reviewer of one or more devices for every 10-year increase in age was 1.5 (95% confidence interval, 1.1, 2.1 [P=0.02]). For every 10 years since diabetes diagnosis, the odds ratio of being a Routine Reviewer was 1.7 (95% confidence interval, 1.2, 2.4 [P=0.01]). For caregivers, there were no statistically significant factors associated with being a Routine Reviewer. CONCLUSIONS: A minority of T1D patients routinely downloads and reviews data from their devices on their own. Further research is needed to understand obstacles, provide better education and tools for self-review, and determine if patient self-review is associated with improved glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653
Peters, A., Laffel, L., & the American Diabetes Association Transitions Working Group (2011) · Diabetes Care · doi:10.2337/dc11-1723 · Cited by 581
Anderson, B., Ho, J., Brackett, J., Finkelstein, D., & Laffel, L. (1997) · The Journal of Pediatrics · doi:10.1016/s0022-3476(97)70352-4 · Cited by 531 · cited 1×
“This agrees with other findings that parental involvement in diabetes management declines as a child progresses through adolescence.(28,29) These findings in both groups indicate that data download and review are most often neglected in adolescents and young adults.”
ResultReal-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Self-citationEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Lowe, J., Linjawi, S., Mensch, M., James, K., & Attia, J. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.02.003 · Cited by 92
Cited by
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
“Attempts to elucidate and establish reliable insulin needs through formalised protocols or during regular clinic visits guided by data uploads [26, 27] are hampered by the need for frequent re-adjustments of insulin requirements.”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Forlenza, G. P., DeSalvo, D. J., Aleppo, G., Wilmot, E. G., Berget, C., Huyett, L. M., Hadjiyianni, I., Méndez, J. J., Conroy, L. R., Ly, T. T., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0578 · Cited by 99
Improved A1C Levels in Type 1 Diabetes with Smartphone App Use
Ryan, E. A., Holland, J., Stroulia, E., Bazelli, B., Babwik, S. A., Li, H., Senior, P., & Greiner, R. (2017) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2016.06.001 · Cited by 63
“Newer technologies involving Bluetooth connectivity allow entry of glucose data from meters into electronic diaries will facilitate record keeping, but only 10% to 12% of peoplewith type 1 diabetes routinely download their capillary glucose testing results for review (2,6).”
BackgroundPilot Study of a Novel Application for Data Visualization in Type 1 Diabetes
Wong, J. C., Neinstein, A. B., Look, H., Arbiter, B., Chokr, N., Ross, C., & Adi, S. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817691305 · Cited by 32
Self-citation
Metadata
- Authors
- Wong, J. C., Neinstein, A. B., Spindler, M., & Adi, S.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2015-08
- Volume
- 17
- Issue
- 8
- Pages
- 555-562
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1492241266
- Cited by
- 64
- References
- 8
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.