Effectiveness of Automated Insulin Management Features of the MiniMed ® 640G Sensor-Augmented Insulin Pump
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Automated insulin management features of the MiniMed® 640G sensor-augmented pump system include suspension in response to predicted low sensor glucose (SG) values (“suspend before low”), suspension in response to existing low SG values (“suspend on low”), and automatic restarting of basal insulin delivery upon SG recovery. The effectiveness of these features was evaluated using CareLink® software data. Methods: Anonymized data from MiniMed 640G system users (n = 4818), MiniMed 530G system users (n = 39,219), and MiniMed Paradigm® Veo™ system users (n = 43,193) who voluntarily uploaded pump and sensor data were retrospectively analyzed. Comparisons were made between days in which system features were enabled at any time and those in which they were not. Comparisons were also made between pump suspension events for which insulin delivery was automatically or manually resumed and between glycemic parameters of users who switched from the MiniMed Paradigm Veo system to the MiniMed 640G system. Results: Days in which the MiniMed 640G “suspend before low” feature was enabled had lower percentages of SG readings ≤70 mg/dL (3.9 mmol/L) or ≥240 mg/dL (13.3 mmol/L) than days when it was not enabled (P < 0.001 for each). Users who switched from the MiniMed Paradigm Veo system to the MiniMed 640G system had fewer excursions below ≤70 mg/dL (P < 0.001) and ≥240 mg/dL (P < 0.001). SG values following automatically resumed pump suspension events recovered more rapidly and had a more stabilized endpoint than following manually resumed events. Conclusions: Automated insulin management features of the MiniMed 640G system can reduce the frequency of both high and low SG values and help stabilize SG after resumption of insulin delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Home Use of an Artificial Beta Cell in Type 1 Diabetes
Thabit, H., Tauschmann, M., Allen, J. M., Leelarathna, L., Hartnell, S., Wilinska, M. E., Acerini, C. L., Dellweg, S., Benesch, C., Heinemann, L., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509351 · Cited by 450 · cited 1×
“In other outpatient studies, HCL systems outperformed sensoraugmented pumps in terms of glucose control, time in hypoglycemia, and glycated hemoglobin levels.(16,17) The MiniMed 640G system is the first commercially available system to offer predictive suspension and automatic resumption, based on SG, of basal insulin…”
BackgroundInsulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
Self-citationPrevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
Garg, S., Brazg, R. L., Bailey, T. S., Buckingham, B. A., Slover, R. H., Klonoff, D. C., Shin, J., Welsh, J. B., & Kaufman, F. R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0292 · Cited by 138
Self-citationChoudhary, P., Olsen, B. S., Conget, I., Welsh, J. B., Vorrink, L., & Shin, J. J. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0324 · Cited by 118 · cited 3×
“The benefits attributable to these features were previously reported in the context of a user evaluation study.(8) Analysis of real-world usage patterns of MiniMed 640G use and the predictive pump suspension feature reported here supports earlier results and establishes the validity of this integrative technology for…”
BackgroundResultInfluentialSelf-citation
Cited by
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Forlenza, G. P., Li, Z., Buckingham, B. A., Pinsker, J. E., Cengiz, E., Wadwa, R. P., Ekhlaspour, L., Church, M. M., Weinzimer, S. A., Jost, E., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0771 · Cited by 246
“Relatively shorter suspensions were seen in the current study, with a mean suspension duration of 18 min per event, whereas suspensions for other trials were 56 and 58min (16,17).”
BackgroundOne year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215
Castle, J. R., El Youssef, J., Wilson, L. M., Reddy, R., Resalat, N., Branigan, D., Ramsey, K., Leitschuh, J., Rajhbeharrysingh, U., Senf, B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0228 · Cited by 152
Dicembrini, I., Cosentino, C., Monami, M., Mannucci, E., & Pala, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01589-3 · Cited by 106
Metadata
- Authors
- Zhong, A., Choudhary, P., McMahon, C., Agrawal, P., Welsh, J. B., Cordero, T. L., & Kaufman, F. R.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2016-10
- Volume
- 18
- Issue
- 10
- Pages
- 657-663
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2524774929
- Cited by
- 77
- References
- 5
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.