A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3)
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To evaluate the effects of continuous glucose monitoring (CGM) on nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with multiple daily insulin injections (MDI); we also evaluated factors related to differences in hypoglycemia confidence in this population. METHODS: Evaluations were performed from the GOLD randomized trial, an open-label multicenter crossover randomized clinical trial (n = 161) over 69 weeks comparing CGM to self-measurement of blood glucose (SMBG) in persons with type 1 diabetes treated with MDI. Masked CGM and the hypoglycemia confidence questionnaire were used for evaluations. RESULTS: Time with nocturnal hypoglycemia, glucose levels <70 mg/dL was reduced by 48% (10.2 vs. 19.6 min each night, P < 0.001) and glucose levels <54 mg/dL by 65%. (3.1 vs. 8.9 min, P < 0.001). For the corresponding glucose cutoffs, daytime hypoglycemia was reduced by 40% (29 vs. 49 min, P < 0.001) and 54% (8 vs. 18 min., P < 0.001), respectively. Compared with SMBG, CGM use improved hypoglycemia-related confidence in social situations (P = 0.016) and confidence in more broadly avoiding serious problems due to hypoglycemia (P = 0.0020). Persons also reported greater confidence in detecting and responding to decreasing blood glucose levels (thereby avoiding hypoglycemia) during CGM use (P = 0.0033) and indicated greater conviction that they could more freely live their lives despite the risk of hypoglycemia (P = 0.022). CONCLUSION: CGM reduced time in both nocturnal and daytime hypoglycemia in persons with type 1 diabetes treated with MDI and improved hypoglycemia-related confidence, especially in social situations, thus contributing to greater well-being and quality of life. TRIAL REGISTRATION: ClinicalTrials.gov , number NCT02092051.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185 · cited 2×
“Furthermore, we used two different time frames for nocturnal hypoglycemia, 22:00–05:59 and 00:00–05:59, since this varied in earlier studies.(11,12) The corresponding hypoglycemia cutoffs were used to evaluate daytime hypoglycemia and for both time periods 06:00–23:59 and 06:00–21:59.”
MethodSelf-citationEffectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · cited 2×
“We recently showed that to obtain an effect of CGM on HbA1c in persons with type 1 diabetes and treated with MDI, continuous use is needed,(7) which has also been shown for insulin pump users.(12,14) In the present study, we found that continuous use of monitoring is needed to obtain beneficial effects on reducing hyp…”
MethodLind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705 · cited 4×
“It is likely that this is a key contributor to broader quality of life benefits and may largely explain the significantly greater overall well-being and treatment satisfaction earlier that was described in the original study report.(7)”
BackgroundMethodResultInfluentialSelf-citationHirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
Self-citationPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Miller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505
Self-citationthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Self-citationMisso, M. L., Egberts, K. J., Page, M., O'Connor, D., & Shaw, J. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005103.pub2 · Cited by 406
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Dicembrini, I., Cosentino, C., Monami, M., Mannucci, E., & Pala, L. (2021) · Acta Diabetologica · doi:10.1007/s00592-020-01589-3 · Cited by 106
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
“Recommendation for the use of rtCGM in T2D by the professional societies All three major U.S. diabetes professional societies have provided evidence-based guidance on the use of CGM for patients with T2D.58–61 All professional organizations have recommended CGM use in selected patients with T2D to improve glycemic con…”
ResultInfluentialSpeight, J., Choudhary, P., Wilmot, E. G., Hendrieckx, C., Forde, H., Cheung, W. Y., Crabtree, T., Millar, B., Traviss‐Turner, G., Hill, A., et al. (2023) · Diabetic Medicine · doi:10.1111/dme.14944 · Cited by 92
Johnson, S. R., Holmes-Walker, D. J., Chee, M., Earnest, A., & Jones, T. W. (2022) · Diabetes Care · doi:10.2337/dc21-1666 · Cited by 86
“The reduction in the incidence of severe hypoglycemia after CGM introduction is consistent with results from randomized trials that have shown significant improvements in time in hypoglycemia with use of CGM (18,19).”
ResultAleppo, G., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · Diabetes Care · doi:10.2337/dc21-1304 · Cited by 82
Self-citationImproved Real-World Glycemic Control With Continuous Glucose Monitoring System Predictive Alerts
Abraham, S. B., Arunachalam, S., Zhong, A., Agrawal, P., Cohen, O., & McMahon, C. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819859334 · Cited by 63
Real-World Data from the First U.S. Commercial Users of an Implantable Continuous Glucose Sensor
Sanchez, P., Ghosh-Dastidar, S., Tweden, K. S., & Kaufman, F. R. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0234 · Cited by 40
“4,7 While randomized controlled studies have been important to establish the role of CGM, real-world data derived from CGM data management systems are also important to establish glucometric outcomes of patients using CGM devices at home.”
Benefits and limitations of continuous glucose monitoring in type 1 diabetes
Stone, J. Y., & Bailey, T. S. (2020) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2020.1706482 · Cited by 30
“of benefit are during sleep [20,26] and physical activity [27].”
BackgroundHypoglycaemia and its management in primary care setting
Ibrahim, M., Baker, J., Cahn, A., Eckel, R. H., El Sayed, N. A., Fischl, A. H., Gaede, P., Leslie, R. D., Pieralice, S., Tuccinardi, D., et al. (2020) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3332 · Cited by 21
Luo, J., Zhang, K., Xu, Y., Tao, Y., & Zhang, Q. (2022) · Journal of Medical Systems · doi:10.1007/s10916-021-01797-6 · Cited by 22
Kawaguchi, Y., Sawa, J., Hamai, C., Nishimura, Y., & Kumeda, Y. (2019) · Journal of Diabetes Investigation · doi:10.1111/jdi.13038 · Cited by 10
Tidemand, K. G., Laugesen, C., Ranjan, A. G., Skovhus, L. B., & Nørgaard, K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0134 · Cited by 9
“6 Despite the increasing CGM use and the subsequent increase in research using CGM data, the available evidence about RH is scarce.”
Metadata
- Authors
- Ólafsdóttir, A. F., Polonsky, W., Bolinder, J., Hirsch, I. B., Dahlqvist, S., Wedel, H., Nyström, T., Wijkman, M., Schwarcz, E., Hellman, J., Heise, T., & Lind, M.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2018-04
- Volume
- 20
- Issue
- 4
- Pages
- 274-284
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W2795486280
- Cited by
- 113
- References
- 13
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.