The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Cross-Linking Electrospun Type II Collagen Tissue Engineering Scaffolds with Carbodiimide in Ethanol
Abstract
In trying to assess the structural integrity of electrospun type II collagen scaffolds, a modified but new technique for cross-linking collagen has been developed. Carbodiimides have been previously used to cross-link collagen in gels and in lyophilized native tissue specimens but had not been used for electrospun mats until recently. This cross-linking agent, and in particular 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC), is of extreme interest, especially for tissue-engineered scaffolds composed specifically of native polymers (e.g., collagen), because it is a zero-length cross-linking agent that has not been shown to cause any cytotoxic reactions. The unique aspect of the cross-linking protocol in this study involves the use of ethanol as the solvent for the cross-linking agent, because the pure collagen electrospun mats immediately disintegrate when placed in an aqueous solution. This study examines 2 concentrations of EDC with and without the addition of N-hydroxysuccinimide to the reaction (which has been shown to result in higher cross-linking yields in aqueous solutions) to test the hypothesis that the use of EDC in a nonaqueous solution will cross-link electrospun type II collagen fibrous matrices in a comparable manner to typical glutaraldehyde fixation protocols. The use of EDC is compared with the cross-linking effects of glutaraldehyde via mechanical testing (uniaxial tensile testing) and biochemical testing (analysis of the percentage of free amino groups). The stress-strain curves of the cross-linked samples demonstrated uniaxial tensile behavior more characteristic of native tissue than do the dry, untreated samples. The heated, 50% glutaraldehyde cross-linking protocol resulted in a mean peak stress of 0.76 MPa, a mean strain at break of 127.30%, and a mean tangential modulus of 0.89 MPa; mean values for the samples treated with the EDC protocols ranged from 0.35 to 0.60 MPa for peak stress, from 111.83 to 159.23% for strain at break, and from 0.57 to 0.92 MPa for tangential modulus. Low and high concentrations (20 mM and 200 mM, respectively) of EDC alone were comparable in extent of cross-linking (29% and 29%, respectively) to the heated 50% glutaraldehyde cross-linking protocol (30% cross-linked).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanometre diameter fibres of polymer, produced by electrospinning
Reneker, D. H., & Chun, I. (1996) · Nanotechnology · doi:10.1088/0957-4484/7/3/009 · Cited by 3,520
Bending instability of electrically charged liquid jets of polymer solutions in electrospinning
Reneker, D. H., Yarin, A. L., Fong, H., & Koombhongse, S. (2000) · Journal of Applied Physics · doi:10.1063/1.373532 · Cited by 2,462
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Self-citationHunziker, E. B. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0801 · Cited by 1,975
Principles of Tissue Engineering
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07193-4 · Cited by 1,906
Strength of biological materials
Yamada, H., & Evans, F. G. (1970) · Cited by 1,136
Review: tissue engineering for regeneration of articular cartilage
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00213-6 · Cited by 1,052
Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactions
Staros, J. V., Wright, R. W., & Swingle, D. M. (1986) · Analytical Biochemistry · doi:10.1016/0003-2697(86)90176-4 · Cited by 898
Rho, K. S., Jeong, L., Lee, G., Seo, B.-M., Park, Y. J., Hong, S.-D., Roh, S., Cho, J. J., Park, W. H., & Min, B.-M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.004 · Cited by 876
Zero-length crosslinking procedure with the use of active esters
Grabarek, Z., & Gergely, J. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90267-d · Cited by 827
Electrospun protein fibers as matrices for tissue engineering
Li, M., Mondrinos, M. J., Gandhi, M. R., Ko, F. K., Weiss, A. S., & Lelkes, P. I. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.030 · Cited by 792
Acellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Encyclopedia of Biomaterials and Biomedical Engineering
(2008) · CRC Press eBooks · doi:10.1201/9780429154065 · Cited by 700
Cross-linking of dermal sheep collagen using a water-soluble carbodiimide
Olde Damink, L. H. H., Dijkstra, P. J., van Luyn, M. J. A., van Wachem, P. B., Nieuwenhuis, P., & Feijen, J. (1996) · Biomaterials · doi:10.1016/0142-9612(96)81413-x · Cited by 697
Electrospinning of collagen and elastin for tissue engineering applications
Buttafoco, L., Kolkman, N. G., Engbers-Buijtenhuijs, P., Poot, A. A., Dijkstra, P. J., Vermes, I., & Feijen, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.024 · Cited by 627
Kidoaki, S., Kwon, I. K., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.063 · Cited by 548
Electrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Atala, A., & Lanza, R. (2002) · Cited by 533
Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
Glutaraldehyde as a fixative in bioprostheses and drug delivery matrices
Jayakrishnan, A., & Jameela, S. R. (1996) · Biomaterials · doi:10.1016/0142-9612(96)82721-9 · Cited by 498
Collagen gel systems for sustained delivery and tissue engineering
Wallace, D. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.004 · Cited by 488
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Nerem, R. M., & Seliktar, D. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.225 · Cited by 466
(1976) · Springer eBooks · doi:10.1007/978-1-4757-4602-0 · Cited by 457
Pieper, J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00240-3 · Cited by 418
Methods for the treatment of collagenous tissues for bioprostheses
Khor, E. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00106-8 · Cited by 415
The Chemistry and Reactivity of Collagen
Gustavson, K. H. (1956) · Medical Entomology and Zoology · Cited by 379
Angele, P., Abke, J., Kujat, R., Faltermeier, H., Schumann, D., Nerlich, M., Kinner, B., Englert, C., Ruszczak, Z., Mehrl, R., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.066 · Cited by 303
Crosslinking of biological tissues using genipin and/or carbodiimide
Sung, H., Chang, W., Ma, C., & Lee, M. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10346 · Cited by 286
Sinz, A. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.559 · Cited by 276
Mechanical Properties and Cellular Proliferation of Electrospun Collagen Type II
Shields, K. J., Beckman, M. J., Bowlin, G. L., & Wayne, J. S. (2004) · Tissue Engineering · doi:10.1089/1076327042500373 · Cited by 262
Self-citationChondrocyte-seeded collagen matrices implanted in a chondral defect in a canine model
Nehrer, S. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00143-4 · Cited by 244
Characterization of collagen gel solutions and collagen matrices for cell culture
Sheu, M.-T., Huang, J.-C., Yeh, G.-C., & Ho, H.-O. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00315-x · Cited by 231
The hydrophobic effect in protein folding
Lins, L., & Brasseur, R. (1995) · The FASEB Journal · doi:10.1096/fasebj.9.7.7737462 · Cited by 211
Electrospinning of Collagen Type II: A Feasibility Study
Matthews, J. A., Boland, E. D., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2003) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911503018002003 · Cited by 193
Self-citationPieper, J. S., van der Kraan, P. M., Hafmans, T., Kamp, J., Buma, P., van Susante, J. L. C., van den Berg, W. B., Veerkamp, J. H., & van Kuppevelt, T. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00067-4 · Cited by 183
Tissue‐engineered skin substitutes: from in vitro constructs to in vivo applications
Auger, F. A., Berthod, F., Moulin, V. J., Pouliot, R., & Germain, L. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030229 · Cited by 165
Miller, E. J., & Lunde, L. G. (1973) · Biochemistry · doi:10.1021/bi00741a003 · Cited by 152
Crosslinking of tissue-derived biomaterials in 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC)
Lee, J. M., Edwards, H., Pereira, C. A., & Samii, S. I. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00122176 · Cited by 139
A Honeycomb Collagen Carrier for Cell Culture as a Tissue Engineering Scaffold
Itoh, H., Aso, Y., 古瀬, 正., D, Y. N. M., & Miyata, T. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025003213.x · Cited by 98
Evaluation of collagen cross‐linking techniques for the stabilization of tissue matrices
Simmons, D., & Kearney, J. (1993) · Biotechnology and Applied Biochemistry · doi:10.1111/j.1470-8744.1993.tb00229.x · Cited by 93
Gratzer, P. F., & Lee, J. M. (2001) · Journal of Biomedical Materials Research · Cited by 72
Application of cross-linked salmon atelocollagen to the scaffold of human periodontal ligament cells
Nagai, N., Yunoki, S., Suzuki, T., et al. (2004) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(04)70224-8 · Cited by 71
DYNAMICS OF CELL–ECM INTERACTIONS
Martins‐Green, M. M. (2000) · Elsevier eBooks · doi:10.1016/b978-012436630-5/50008-8 · Cited by 32
Cited by
Biopolymer-Based Hydrogels As Scaffolds for Tissue Engineering Applications: A Review
Van Vlierberghe, S., Dubruel, P., & Schacht, E. (2011) · Biomacromolecules · doi:10.1021/bm200083n · Cited by 1,716
3D bioactive composite scaffolds for bone tissue engineering
Turnbull, G., Clarke, J., Picard, F., Riches, P., Jia, L., Han, F., Li, B., & Shu, W. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.10.001 · Cited by 1,332
Advancing biomaterials of human origin for tissue engineering
Chen, F.-M., & Liu, X. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2015.02.004 · Cited by 1,158
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Nanofiber technology: Designing the next generation of tissue engineering scaffolds
Barnes, C. P., Sell, S. A., Boland, E. D., Simpson, D. G., & Bowlin, G. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.022 · Cited by 1,141
Self-citation
Metadata
- Authors
- Barnes, C. P., Pemble, C. W., Brand, D. D., Simpson, D. G., & Bowlin, G. L.
- Venue
- Tissue Engineering
- Publisher
- SAGE Publications
- Published
- 2007-07
- Volume
- 13
- Issue
- 7
- Pages
- 1593-1605
- ISSN
- 1076-3279 (ISSN-L)
- 1557-8690
- OpenAlex
- W2013035214
- Cited by
- 253
- References
- 44
- FWCI
- 7.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.