CoChat

Cyclic Strain Affects Macrophage Cytokine Secretion and Extracellular Matrix Turnover in Electrospun Scaffolds

Open access
Bonito, Valentina, de Kort, Bente J., Bouten, Carlijn V.C., Smits, Anthal I.P.M. · 2019 · Tissue Engineering Part A
Cited by 37

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Controlling macrophage behavior has become a high-potential target strategy for regenerative therapies, such as in situ tissue engineering (TE). In situ TE is an approach, in which acellular resorbable synthetic scaffolds are used, to induce endogenous tissue regeneration. However, little is known regarding the effect of the biomechanical environment on the macrophage response to a scaffold. Therefore, the aim of this study was to assess the effect of cyclic strains (0%, 8%, and 14% strain) on primary human macrophage polarization in electrospun scaffolds with two different fiber diameters in the micrometer range (4 μm or 13 μm). High strains led to a proinflammatory profile in terms of gene expression, expression of surface proteins, and cytokine secretion. These results were consistent for scaffolds with small and large fiber diameters, indicating that the effect of cyclic strain was not affected by the different scaffold microstructures. Notably, macrophages were identified as direct contributors of early secretion of extracellular matrix proteins, including elastin, which was deposited in a strain-dependent manner. These findings are instrumental for the rational design of scaffolds for in situ TE and underline that immunomodulatory scaffolds for biomechanically loaded applications should be mechanically tailored, for example, in terms of stiffness and compliance, to support a desirable proregenerative macrophage phenotype. Impact Statement: Electrospun elastomeric scaffolds are being used for a variety of in situ tissue engineering applications, in which biomechanical loads play a dominant in vivo role, such as cardiovascular replacements (e.g., heart valve and blood vessel prostheses) and pelvic floor reconstruction. The findings of this study underline that immunomodulatory scaffolds for biomechanically loaded applications should be mechanically tailored, for example, in terms of stiffness and compliance, to support a desirable proregenerative macrophage phenotype. Moreover, this research contributes to the general understanding of pathophysiological macrophage phenotypes in cyclically strained tissues (e.g., atherosclerotic plaques), and their role in tissue regeneration and degeneration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tea.2018.0306

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Bonito, V., de Kort, B. J., Bouten, C. V. C., & Smits, A. I. P. M.
Venue
Tissue Engineering Part A
Published
2019-09
Volume
25
Issue
17-18
Pages
1310-1325
ISSN
  • 1937-3341 (ISSN-L)
  • 1937-335X
OpenAlex
W2943255416
Cited by
37
References
10
FWCI
1.02
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.