CoChat

Determining the Optimal Decellularization and Sterilization Protocol for Preparing a Tissue Scaffold of a Human-Sized Liver Tissue

Kajbafzadeh, Abdol-Mohammad, Javan-Farazmand, Niloufar, Monajemzadeh, Maryam, Baghayee, Arash · 2013 · Tissue Engineering Part C: Methods
Cited by 125

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Attaining a well-qualified whole decellularized organ applicable for an enduring and successful transplantation, decellularization protocols should be organ specific in terms of decellularizing agents and time of tissue exposure. Since a bioscaffold resulting from a large solid organ should have the potential to preserve its three-dimensional architecture and consistency for at least several months in the site of transplantation, evaluating the mechanical properties of the bioscaffold is mandatory before transplantation. In the current study, we compared five different decellularization protocols and also two main decellularization techniques (perfusion vs. diffusion) to decellularize the sheep liver, which is similar to the human liver in terms of size and anatomy. Moreover, we assessed the retaining of vascular network by dye injection and angiography. We also determined the most proper sterilization method by comparing six different sterilization methods. The mechanical properties of the scaffolds were assessed by applying tensile strength, suture retention, and compressive strength tests. The perfusion technique showed better results compared to the diffusion technique. The protocol containing ammonium hydroxide and triton X-100 was the most proper decellularization protocol leading to completely decellularized livers along with intact vascular network. Furthermore, we noted that application of streptokinase in washing step facilitates decellularization. Our results also showed that a combination of two sterilization methods is necessary for complete sterilization of a sheep liver and peracetic acid or ethylene oxide+gamma irradiation was associated with the best outcome. Determining the most appropriate decellularization and sterilization method for each organ along with assessing the mechanical properties of the resulting bioscaffold are principal steps before fabricating efficient artificial organs in the foreseeable future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/ten.tec.2012.0334

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 125

Metadata

Authors
Kajbafzadeh, A.-M., Javan-Farazmand, N., Monajemzadeh, M., & Baghayee, A.
Venue
Tissue Engineering Part C: Methods
Published
2013-08
Volume
19
Issue
8
Pages
642-651
ISSN
  • 1937-3384 (ISSN-L)
  • 1937-3392
OpenAlex
W2017292362
Cited by
125
References
10
FWCI
7.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determining the Optimal Decellularization and Sterilization Protocol for Preparing a Tissue Scaffold of a Human-Sized Liver Tissue. https://app.cochat.ai/papers/10.1089/ten.tec.2012.0334
The paper
Kajbafzadeh, A.-M., Javan-Farazmand, N., Monajemzadeh, M., & Baghayee, A. (2013). Determining the Optimal Decellularization and Sterilization Protocol for Preparing a Tissue Scaffold of a Human-Sized Liver Tissue. Tissue Engineering Part C: Methods. https://doi.org/10.1089/ten.tec.2012.0334

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.