Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
A new air displacement method for the determination of human body composition
DEMPSTER, P., & AITKENS, S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00017 · Cited by 678
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317 · cited 1×
“DXA is arguably one of the best reference methods to use: it has been validated against other methods of bodycomposition analysis and has shown little bias based on age, sex, physical activity levels, race, or proportion of fat (14).”
MethodJohansen, K. L., Mulligan, K., & Schambelan, M. (1999) · JAMA · doi:10.1001/jama.281.14.1275 · Cited by 275
Measurement of fat mass using DEXA: a validation study in elderly adults
Salamone, L. M., Fuerst, T., Visser, M., Kern, M., Lang, T., Dockrell, M., Cauley, J. A., Nevitt, M., Tylavsky, F., & Lohman, T. G. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.345 · Cited by 233
Das, S. K., Roberts, S. B., Kehayias, J. J., Wang, J., Hsu, L. K. G., Shikora, S. A., Saltzman, E., & McCrory, M. A. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00185.2002 · Cited by 183 · cited 1×
“Because BIA is used to measure body composition in a variety of clinical settings, such as in patients with AIDS wasting (3) or chronic obesity (39), this bias must be taken into consideration when interpreting BIA data.”
MethodBolanowski, M., & Nilsson, B. E. (2002) · PubMed · Cited by 178
Tyrrell, V., Richards, G., Hofman, P., Gillies, G., Robinson, E., & Cutfield, W. (2001) · International Journal of Obesity · doi:10.1038/sj.ijo.0801531 · Cited by 175
Sawaya, A. L., Martins, P., Hoffman, D. J., & Roberts, S. B. (2003) · Nutrition Reviews · doi:10.1301/nr.2003.may.168-175 · Cited by 159
Cited by
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Stote, K. S., Baer, D. J., Spears, K., Paul, D. R., Harris, G. K., Rumpler, W. V., Strycula, P., Najjar, S. S., Ferrucci, L., Ingram, D. K., et al. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.4.981 · Cited by 392
“BIA may also not be the best method for assessing body composition because of its tendency to overestimate fat mass in lean subjects (38).”
MethodBatsis, J. A., Barre, L. K., Mackenzie, T. A., Pratt, S. I., Lopez‐Jimenez, F., & Bartels, S. J. (2013) · Journal of the American Geriatrics Society · doi:10.1111/jgs.12260 · Cited by 330
A review of sarcopenia: Enhancing awareness of an increasingly prevalent disease
Marty, E., Liu, Y., Samuel, A., Or, O., & Lane, J. (2017) · Bone · doi:10.1016/j.bone.2017.09.008 · Cited by 288
Bowen, J., Noakes, M., & Clifton, P. M. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0609 · Cited by 287
Assessing Body Composition With DXA and Bioimpedance: Effects of Obesity, Physical Activity, and Age
Völgyi, E., Tylavsky, F. A., Lyytikäinen, A., Suominen, H., Alén, M., & Cheng, S. (2008) · Obesity · doi:10.1038/oby.2007.94 · Cited by 274
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
Stanhope, K. L., Griffen, S. C., Bair, B. R., Swarbrick, M. M., Keim, N. L., & Havel, P. J. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.5.1194 · Cited by 228
“Bioelectrical impedance measurements of body fat in healthy adults has been shown to correlate well with body fat measurements by dual-energy X-ray absorptiometry (17, 18).”
BackgroundThe use of bioelectrical impedance analysis for body composition in epidemiological studies
Böhm, A., & Heitmann, B. L. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.168 · Cited by 204
Thomson, R., Brinkworth, G. D., Buckley, J. D., Noakes, M., & Clifton, P. M. (2007) · Clinical Nutrition · doi:10.1016/j.clnu.2007.08.003 · Cited by 200
Comparison of Three Bioelectrical Impedance Methods with DXA in Overweight and Obese Men
Pateyjohns, I. R., Brinkworth, G. D., Buckley, J. D., Noakes, M., & Clifton, P. M. (2006) · Obesity · doi:10.1038/oby.2006.241 · Cited by 187
“The results of this study and of the two previous studies (14,22) indicate that MF-BIA provides a poor level of absolute agreement with DXA, indicating that MF-BIA may not be suitable for the measurement of body composition in clinical research.”
MethodResultInfluentialShea, J. L., King, M. T. C., Yi, Y., Gulliver, W., & Sun, G. (2012) · Nutrition, Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2010.11.009 · Cited by 167
“We have shown that BIA tends to overestimate %BF in lean adults and underestimate %BF in obese adults compared to DXA, a more accurate reference method [13].”
MethodSelf-citationBioelectrical impedance underestimates total and truncal fatness in abdominally obese women
Neovius, M., Hemmingsson, E., Freyschuss, B., & Uddén, J. (2006) · Obesity · doi:10.1038/oby.2006.199 · Cited by 119
A comparison of three methods to assess body composition.
Tewari, N., Awad, S., Macdonald, I. A., & Lobo, D. N. (2018) · Nutrition · doi:10.1016/j.nut.2017.09.005 · Cited by 104
Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A. (2010) · Obesity Surgery · doi:10.1007/s11695-009-0006-5 · Cited by 100
The Influence of Increased Body Fat or Lean Body Mass on Aerobic Performance
Maciejczyk, M., Więcek, M., Szymura, J., Szyguła, Z., Wiecha, S., & Cempla, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095797 · Cited by 99
Microvascular dysfunction in healthy insulin-sensitive overweight individuals
Czernichow, S., Greenfield, J. R., Galan, P., Bastard, J.-P., Charnaux, N., Samaras, K., Safar, M. E., Blacher, J., Hercberg, S., & Levy, B. I. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e328333d1fc · Cited by 64
Becroft, L., Ooi, G., Forsyth, A., King, S., & Tierney, A. (2019) · International Journal of Obesity · doi:10.1038/s41366-018-0285-9 · Cited by 51
Fakhrawi, D. H., Beeson, L., Libanati, C., Feleke, D., Kim, H., Quansah, A., Darnell, A., Lammi-Keefe, C. J., & Cordero-MacIntyre, Z. (2009) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2009.01.004 · Cited by 48
Jayanama, K., Putadechakun, S., Srisuwarn, P., Vallibhakara, S. A.-O., Chattranukulchai Shantavasinkul, P., Sritara, C., Kantachuvesiri, S., & Komindr, S. (2018) · Journal of Nutrition and Metabolism · doi:10.1155/2018/4537623 · Cited by 48
Zhou, X., Xing, B., He, G., Lyu, X., & Zeng, Y. (2018) · Obesity Facts · doi:10.1159/000491797 · Cited by 44
Chen, K.-T., Chen, Y.-Y., Wang, C.-W., Chuang, C.-L., Chiang, L.-M., Lai, C.-L., Lu, H.-K., Dwyer, G. B., Chao, S.-P., Shih, M.-K., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0160105 · Cited by 43
“However, according to the results of our study, BF%BIA8 had a higher correlation with BF%DXA than BF% did when estimated by a supine posture BIA [9].”
MethodResultInfluentialMaalin, N., Mohamed, S., Kramer, R. S. S., Cornelissen, P. L., Martin, D., & Tovée, M. J. (2021) · Behavior Research Methods · doi:10.3758/s13428-020-01494-1 · Cited by 25
“This technique shows good agreement compared to dualenergy X-ray absorptiometry (e.g. Ling et al., 2011; Sun et al., 2005; Wattanapenpaiboon, Lukito, Strauss, HsuHage, Wahlqvist, & Stroud, 1998) and skinfold calliper measurements (Kitano, Kitano, Inomoto, & Futatsuka, 2001).”
Eng, P. C., Teo, A. E. D., Leow, M. K. S., Tai, E. S., & Khoo, C. M. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.16601 · Cited by 32
“41 Another study in people with obesity showed that BIA, compared with DEXA, significantly overestimated fat-free mass and underestimated fat mass by (cid:4) 4 kg, but the accuracy could be enhanced using derived equations.”
Metadata
- Authors
- Sun, G., French, C. R., Martin, G. R., Younghusband, B., Green, R. C., Xie, Y.-G., Mathews, M., Barron, J. R., Fitzpatrick, D. G., Gulliver, W., & Zhang, H.
- Venue
- The American Journal of Clinical Nutrition
- Publisher
- Elsevier BV
- Published
- 2005-01
- Volume
- 81
- Issue
- 1
- Pages
- 74-78
- ISSN
- 0002-9165 (ISSN-L)
- OpenAlex
- W2097052470
- Cited by
- 377
- References
- 36
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.