How Many Measurements Are Needed to Estimate Blood Pressure Variability Without Loss of Prognostic Information?
Open accessThe DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Average real variability (ARV) is a recently proposed index for short-term blood pressure (BP) variability. We aimed to determine the minimum number of BP readings required to compute ARV without loss of prognostic information. METHODS: ARV was calculated from a discovery dataset that included 24-hour ambulatory BP measurements for 1,254 residents (mean age = 56.6 years; 43.5% women) of Copenhagen, Denmark. Concordance between ARV from full (≥80 BP readings) and randomly reduced 24-hour BP recordings was examined, as was prognostic accuracy. A test dataset that included 5,353 subjects (mean age = 54.0 years; 45.6% women) with at least 48 BP measurements from 11 randomly recruited population cohorts was used to validate the results. RESULTS: In the discovery dataset, a minimum of 48 BP readings allowed an accurate assessment of the association between cardiovascular risk and ARV. In the test dataset, over 10.2 years (median), 806 participants died (335 cardiovascular deaths, 206 cardiac deaths) and 696 experienced a major fatal or nonfatal cardiovascular event. Standardized multivariable-adjusted hazard ratios (HRs) were computed for associations between outcome and BP variability. Higher diastolic ARV in 24-hour ambulatory BP recordings predicted (P < 0.01) total (HR = 1.12), cardiovascular (HR = 1.19), and cardiac (HR = 1.19) mortality and fatal combined with nonfatal cerebrovascular events (HR = 1.16). Higher systolic ARV in 24-hour ambulatory BP recordings predicted (P < 0.01) total (HR = 1.12), cardiovascular (HR = 1.17), and cardiac (HR = 1.24) mortality. CONCLUSIONS: Forty-eight BP readings over 24 hours were observed to be adequate to compute ARV without meaningful loss of prognostic information.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Monitoring ambulatory BP levels for 48 h and with more frequent readings (every 15 min) might improve the clinical relevance of estimated BPV52,53.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [53]
In the citing paper
“For example, ARV is more dependent on the number of ambulatory BP readings than the standard deviation41,42,53.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [53]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Authors/Task Force Members:, Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehm236 · Cited by 2,384
Self-citationOhkubo, T., Hozawa, A., Yamaguchi, J., Kikuya, M., Ohmori, K., Michimata, M., Matsubara, M., Hashimoto, J., Hoshi, H., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200211000-00017 · Cited by 1,053
Self-citationPrognostic Significance of Blood Pressure and Heart Rate Variabilities: The Ohasama Study
Kikuya, M., Hozawa, A., Ohokubo, T., Tsuji, I., Michimata, M., Matsubara, M., Ota, M., Nagai, K., Araki, T., Satoh, H., et al. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.901 · Cited by 609
Self-citationA reliable index for the prognostic significance of blood pressure variability
Mena, L., Pintos, S., Queipo, N. V., Aizpúrua, J. A., Maestre, G., & Sulbarán, T. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160205.81652.5a · Cited by 523 · cited 2×
“where n is the number of BP readings and wk is the time interval between BPk and BPk-1.(1,2)”
Self-citationHansen, T. W., Thijs, L., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.140798 · Cited by 480 · cited 2×
“where n is the number of BP readings and wk is the time interval between BPk and BPk-1.(1,2)”
Self-citation(2019) · Journal of Human Hypertension · doi:10.1038/41371.1476-5527 · Cited by 389
Ambulatory Blood Pressure: Normality and Comparison With Other Measurements
Schettini, C., Bianchi, M., Nieto, F., Sandoya, E., & Senra, H. (1999) · Hypertension · doi:10.1161/01.hyp.34.4.818 · Cited by 349
Self-citationPringle, E., Phillips, C., Thijs, L., Davidson, C., Staessen, J. A., de Leeuw, P. W., Jaaskivi, M., Nachev, C., Parati, G., O'Brien, E. T., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200312000-00012 · Cited by 348
Self-citationAmbulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317
Self-citationDiurnal Blood Pressure Pattern and Risk of Congestive Heart Failure
Ingelsson, E., Björklund-Bodegård, K., Lind, L., Ärnlöv, J., & Sundström, J. (2006) · JAMA · doi:10.1001/jama.295.24.2859 · Cited by 295
Self-citationPrognostic Value of Different Indices of Blood Pressure Variability in Hypertensive Patients
Pierdomenico, S. D., Di Nicola, M., Esposito, A. L., Di Mascio, R., Ballone, E., Lapenna, D., & Cuccurullo, F. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2009.103 · Cited by 264
A note on the generalized information criterion for choice of a model
ATKINSON, A. C. (1980) · Biometrika · doi:10.1093/biomet/67.2.413 · Cited by 262
O??Brien, E., Murphy, J., Tyndall, A., Atkins, N., Mee, F., McCarthy, G., Staessen, J., Cox, J., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199104000-00007 · Cited by 251
Self-citationAmbulatory Blood Pressure Monitoring and Risk of Cardiovascular Disease: A Population Based Study
HANSEN, T., JEPPESEN, J., RASMUSSEN, S., IBSEN, H., & TORPPEDERSEN, C. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.09.018 · Cited by 249
Self-citationBilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka-Jaszcz, K., Mancia, G., & Parati, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32829c6a60 · Cited by 246
Self-citationContinuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
Palatini, P., Mormino, P., Canali, C., Santonastaso, M., De Venuto, G., Zanata, G., & Pessina, A. C. (1994) · Hypertension · doi:10.1161/01.hyp.23.2.211 · Cited by 185
Zhang, Y., Agnoletti, D., Safar, M. E., & Blacher, J. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.174383 · Cited by 162
Trazzi, S., Mutti, E., Frattola, A., Imholz, B., Parati, G., & Mancia, G. (1991) · Journal of Hypertension · doi:10.1097/00004872-199102000-00003 · Cited by 158
Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Li, Y., Dolan, E., Tikhonoff, V., Seidlerová, J., Kuznetsova, T., Stolarz, K., et al. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280f813bc · Cited by 150
Self-citationEguchi, K., Hoshide, S., Schwartz, J. E., Shimada, K., & Kario, K. (2012) · American Journal of Hypertension · doi:10.1038/ajh.2012.75 · Cited by 146
Ambulatory blood pressure: normality and comparison with other measurements.
Staessen, J., & O'Brien, E. (1999) · HYPERTENSION · doi:10.1161/01.hyp.35.3.e8 · Cited by 127
Self-citationAn epidemiological approach to ambulatory blood pressure monitoring:the Belgian Population Study.
Staessen, J. A., Bieniaszewski, L., O'Brien, E. T., Imai, Y., & Fagard, R. (1996) · PubMed · Cited by 113
Self-citationQuality control of the blood pressure phenotype in the European Project on Genes in Hypertension
Kuznetsova, T., Staessen, J. A., Kawecka-Jaszcz, K., Babeanu, S., Casiglia, E., Filipovsky, J., Nachev, C., Nikitin, Y., Peleskã, J., & OʼBrien, E. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200208000-00003 · Cited by 104
Self-citationLi, Y., Wang, J.-G., Gao, P., Guo, H., Nawrot, T., Wang, G., Qian, Y., Staessen, J. A., & Zhu, D. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200506000-00003 · Cited by 69
Self-citationReduction of blood pressure variability: a new strategy for the treatment of hypertension
Su, D., & Miao, C. (2005) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2005.06.003 · Cited by 68
LI, Y., WANG, J., GAO, P., GUO, H., NAWROT, T., WANG, G., QIAN, Y., STAESSEN, J., & ZHU, D. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.03.098 · Cited by 67
Self-citationReproducibility of ambulatory blood pressure monitoring in daily practice
van der Steen, M. S., Lenders, J. W. M., Graafsma, S. J., den Arend, J., & Thien, T. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000808 · Cited by 66
Relation between insulin and aortic stiffness: a population-based study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. T. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001620 · Cited by 64
Self-citationReproducibility of ambulatory blood pressure in treated and untreated hypertensive patients
Eguchi, K., Hoshide, S., Hoshide, Y., Ishikawa, S., Shimada, K., & Kario, K. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283378477 · Cited by 60
The Maracaibo Aging Study: Population and Methodological Issues
Maestre, G. E., Pino-Ramírez, G., Molero, A. E., Silva, E. R., Zambrano, R., Falque, L., Gamero, M. P., & Sulbarán, T. A. (2002) · Neuroepidemiology · doi:10.1159/000059524 · Cited by 60
Self-citationStenehjem, A., & Os, I. (2004) · Blood Pressure · doi:10.1080/08037050410021432 · Cited by 59
Validity and usefulness of non-invasive ambulatory blood pressure monitoring.
Mancia, G., Parati, G., Pomidossi, G. A., & Rienzo, M. D. (1985) · PubMed · Cited by 43
Parati, G., & Rizzoni, D. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160200.51158.9a · Cited by 42
Number of measurements required for the analysis of diurnal blood pressure profile.
Thijs, L., Staessen, J. A., Fagard, R. H., Zachariah, P. K., & Amery, A. (1994) · PubMed · Cited by 41
Self-citationAmbulatory blood pressure of adults in Novosibirsk, Russia: interim report on a population study
Kuznetsova, T. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)01501-1 · Cited by 36
Self-citationBlood Pressure Variability Remains an Elusive Predictor of Cardiovascular Outcome
Hansen, T. W., Li, Y. R., & Staessen, J. A. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.322 · Cited by 31
Self-citationAmbulatory blood pressure of adults in Novosibirsk, Russia: interim report on a population study
Kuznetsova, T., Malyutina, S., Pello, E., Thijs, L., Nikitin, Y., & Staessen, J. A. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200010000-00007 · Cited by 31
Self-citationVeerabhadrappa, P., Diaz, K. M., Feairheller, D. L., Sturgeon, K. M., Williamson, S. T., Crabbe, D. L., Kashem, A. M., Ahrensfield, D. C., & Brown, M. D. (2010) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2010.04.005 · Cited by 24
Fleming, A. M. (1967) · BMJ · doi:10.1136/bmj.3.5559.244-a · Cited by 19
Kikuya, M., Staessen, J. A., Ohkubo, T., Thijs, L., Asayama, K., Satoh, M., Hashimoto, T., Hirose, T., Metoki, H., Obara, T., et al. (2010) · Hypertension Research · doi:10.1038/hr.2010.240 · Cited by 12
Self-citation
Research works printed but not linked: 1
- Mancia, 1985, Journal of hypertension. Supplement : official journal of the International Society of Hypertension, 3, S5
Cited by
Blood pressure variability and cardiovascular disease: systematic review and meta-analysis
Stevens, S. L., Wood, S., Koshiaris, C., Law, K., Glasziou, P., Stevens, R. J., & McManus, R. J. (2016) · BMJ · doi:10.1136/bmj.i4098 · Cited by 871
Blood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Parati, G., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Castiglioni, P., Stergiou, G. S., Mancia, G., Asayama, K., Asmar, R., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003363 · Cited by 220
Self-citationMena, L. J., Felix, V. G., Melgarejo, J. D., & Maestre, G. E. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006895 · Cited by 215
“1%.(37,38) However, these results might have been influenced by different methods of 24-hour ABPM used in the different cohort studies whose data were pooled in the analysis.”
MethodSelf-citationWei, F.-F., Li, Y., Zhang, L., Xu, T.-Y., Ding, F.-H., Wang, J.-G., & Staessen, J. A. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02681 · Cited by 142
“Turning to BP variability assessed from intermittent 24-hour ambulatory recordings, we previously demonstrated that ≥48 readings are required to compute BP variability without loss of prognostic information.(20) Tatasciore et al(2) reported in 180 untreated participants that LVMI was independently associated with awak…”
Self-citation
Metadata
- Authors
- Mena, L. J., Maestre, G. E., Hansen, T. W., Thijs, L., Liu, Y., Boggia, J., Li, Y., Kikuya, M., Bjorklund-Bodegard, K., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., Dolan, E., Kuznetsova, T., Stolarz-Skrzypek, K., Tikhonoff, V., Malyutina, S., Casiglia, E., Nikitin, Y., Lind, L., Sandoya, E., Kawecka-Jaszcz, K., Filipovsky, J., lmai, Y., Wang, J., O'Brien, E., Staessen, J. A., & the International Database on Ambulatory Blood Pressure in Relation to Cardiovascular Outcomes (IDACO) Investigators
- Affiliations
- Universidad del Zulia (VE)
- KU Leuven (BE)
- Universidad de la República de Uruguay (UY)
- Shanghai Jiao Tong University (CN)
- Tohoku University (JP)
- Aalborg University (DK)
- Addenbrooke's Hospital (GB)
- University of Padua (IT)
- Uppsala University (SE)
- University College Dublin (IE)
- Maastricht University (NL)
- ORCID
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-08-16
- Volume
- 27
- Issue
- 1
- Pages
- 46-55
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- PMC
- PMC3848629
- OpenAlex
- W2169301911
- Cited by
- 72
- References
- 46
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 8 · 2023: 6 · 2022: 7 · 2021: 2 · 2020: 4 · 2019: 7 · 2018: 5 · 2017: 7 · 2016: 5 · 2015: 1 · 2014: 3
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- American Journal of Hypertension (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Homo Politicus (Academy of Humanities and Economics in Lodz) (submittedVersion)
- Jagiellonian University Repository (Jagiellonian University) (submittedVersion, other-oa)
- Homo Politicus (Academy of Humanities and Economics in Lodz) (submittedVersion, cc-by-nc-nd)
- ScholarWorks @ UTRGV (The University of Texas Rio Grande Valley) (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Lirias (submittedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Funders
- Hjerteforeningen (01-2-9-9A-22914)
- European Commission (LSHM-CT-2006-037093, 201550, 278249)
- Ministry of Education, Culture, Sports, Science and Technology (23390171, 23790242, 23249036)
- National Natural Science Foundation of China (30871360, 30871081)
- Ministry of Health, Labour and Welfare
- Universidad de la República Uruguay (IC15-CT98-0329-EPOGH)
- Fondo Nacional de Ciencia Tecnología e Innovación (G‐97000726)
- Vlaamse regering
- H. Lundbeck A/S
- National Institutes of Health
- Japan Society for the Promotion of Science (25253059)
- Comisión Sectorial de Investigación Científica
- National Institute on Aging (R01AG036469)
- Fogarty International Center
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- blood pressure variability, average real variability, 24-hour ambulatory blood pressure monitoring, sample size adequacy, prognostic accuracy, cardiovascular mortality, cardiac mortality, cerebrovascular events, diastolic blood pressure, systolic blood pressure
- MeSH terms
- Aged, Antihypertensive Agents, Blood Pressure, Cause of Death, Denmark, Female, Humans, Hypertension, Male, Middle Aged, Predictive Value of Tests, Prognosis, Risk Factors, Time Factors, Reproducibility of Results, Multivariate Analysis, Chi-Square Distribution, Proportional Hazards Models, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.