Respiratory Performance Offered by N95 Respirators and Surgical Masks: Human Subject Evaluation with NaCl Aerosol Representing Bacterial and Viral Particle Size Range
Open accessThe DOI matches its Crossref record; 31 of the 34 references it cites were found in a registry or an index.
Abstract
Objectives: This study aimed at determining the protection factors (PFs) provided by N95 filtering facepiece respirators and surgical masks against particles representing bacterial and viral size ranges (aerodynamic size: 0.04–1.3 μm). Methods: The protection levels of N95 filtering facepiece respirators (four models) and surgical masks (three models) were investigated while they were donned by 12 subjects performing the OSHA (US Occupational Safety and Health Administration) fit-testing exercises in a test chamber. Results: About 29% of N95 respirators and ∼100% of surgical masks had PFs <10, which is the assigned PF designated for this type of respirator by the OSHA. On average, the PFs of N95 respirators were 8–12 times greater than those of surgical masks. The minimum PFs were observed in the size range of 0.04–0.2 μm. No significant difference in PF results was found between N95 respirators with and without an exhalation valve. Conclusions: The study indicates that N95 filtering facepiece respirators may not achieve the expected protection level against bacteria and viruses. An exhalation valve on the N95 respirator does not affect the respiratory protection; it appears to be an appropriate alternative to reduce the breathing resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“To our knowledge, there have been two studies that have measured the total inward leakage on a variety of surgical and procedure masks [55, 59], and currently only one study that has measured the TIL for home-made masks made of cloth materials with testing performed on only one volunteer [85].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [59]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“N95 FFRs have shown less filter penetration, fewer face seal leaks, and less total inward leakage than surgical masks under laboratory conditions (Lee et al., 2008;Grinshpun et al., 2009;Smith et al., 2016)”
From Size-selective Assessment of Respirator Protection against Airborne Fungi and (1→3)-β-D-glucan in Farms (2018) · cites this paper as Lee et al., 2008
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Measured protection factors (PFs) of N95 FFRs when worn in the workplace have been shown to give considerably lower protection [58, 59]”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [59]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“N95 FFR are employed as personal protective equipment (PPE) and they provide a high level of protection for filtering facepiece masks that cover only the nose and mouth (as opposed to full and half-face respirators constructed from elastomeric materials) [3, 58–74].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [59]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Respirators were found to be less protective when facing smaller particles (Lee et al., 2005a(Lee et al., , 2008(Lee et al., , 2016(Lee et al., , 2017))”
From Size-selective Assessment of Respirator Protection against Airborne Fungi and (1→3)-β-D-glucan in Farms (2018) · cites this paper as Lee et al., 2008
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Practice of Infectious Diseases.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-818_5 · Cited by 12,025
A Novel Coronavirus Associated with Severe Acute Respiratory Syndrome
Ksiazek, T. G., Erdman, D., Goldsmith, C. S., Zaki, S. R., Peret, T., Emery, S., Tong, S., Urbani, C., Comer, J. A., Lim, W., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa030781 · Cited by 4,344 · cited 2×
“For comparison, the physical size of an SARS-causing coronavirus is about 0.08–0.14 lm (Ksiazek et al., 2003) and that of an H5N1 virus, which causes Avian influenza, is 0.08–0.12 lm (Mandell et al., 1995).”
BackgroundInfluentialHuman Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Influenza Virus Transmission Is Dependent on Relative Humidity and Temperature
Lowen, A. C., Mubareka, S., Steel, J., & Palese, P. (2007) · PLoS Pathogens · doi:10.1371/journal.ppat.0030151 · Cited by 1,669 · cited 3×
“(Lowen et al., 2007).”
BackgroundInfluentialReview of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 1×
“The size of infective airborne viral particles is not well known and the aerosol transmission of viral diseases is currently debated in the literature (Roy and Milton, 2004; Tellier, 2006).”
BackgroundPrinciples and Practices of Infectious Diseases
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-10-799_1 · Cited by 681 · cited 1×
“For comparison, the physical size of an SARS-causing coronavirus is about 0.08–0.14 lm (Ksiazek et al., 2003) and that of an H5N1 virus, which causes Avian influenza, is 0.08–0.12 lm (Mandell et al., 1995).”
BackgroundInfluentialBałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
Self-citationAirborne Transmission of Communicable Infection — The Elusive Pathway
Roy, C. J., & Milton, D. K. (2004) · New England Journal of Medicine · doi:10.1056/nejmp048051 · Cited by 342 · cited 1×
“The size of infective airborne viral particles is not well known and the aerosol transmission of viral diseases is currently debated in the literature (Roy and Milton, 2004; Tellier, 2006).”
BackgroundDetection of SARS-associated Coronavirus in Throat Wash and Saliva in Early Diagnosis
Wang, W.-K., Chen, S.-Y., Liu, I.-J., Chen, Y.-C., Chen, H.-L., Yang, C.-F., Chen, P.-J., Yeh, S.-H., Kao, C.-L., Huang, L.-M., et al. (2004) · Emerging Infectious Diseases · doi:10.3201/eid1007.031113 · Cited by 266 · cited 1×
“SARS is caused by a coronavirus, which has been found in patients’ body fluids and respiratory secretions such as feces, saliva and sneezing and coughing droplets from nose and mouth (Nassiri, 2003; Wang et al., 2004).”
Background(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 234
Self-citationDifference between the spore sizes of Bacillus anthracis and other Bacillus species
Carrera, M., Zandomeni, R. O., Fitzgibbon, J., & Sagripanti, J.-L. (2007) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2006.03111.x · Cited by 196 · cited 2×
“The average physical size of B. anthracis is about 0.81–0.86 lm in diameter and 1.26–1.67 lm in length (Carrera et al., 2007).”
BackgroundInfluentialManaging SARS amidst Uncertainty
Wenzel, R. P., & Edmond, M. B. (2003) · New England Journal of Medicine · doi:10.1056/nejmp030072 · Cited by 154
Comparison of Performance of Three Different Types of Respiratory Protection Devices
Lawrence, R. B., Duling, M. G., Calvert, C. A., & Coffey, C. C. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620600829211 · Cited by 127 · cited 3×
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
BackgroundMethodResultSevere Acute Respiratory Syndrome
Masur, H., Emanuel, E., & Lane, H. C. (2003) · JAMA · doi:10.1001/jama.289.21.jed30036 · Cited by 126
Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119 · cited 3×
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
BackgroundMethodThe Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93 · cited 2×
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
MethodResultInfluentialCHARACTERISTICS OF FACE SEAL LEAKAGE IN FILTERING FACEPIECES
Chen, C. C., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360120 · Cited by 82 · cited 3×
“This supports the results of several previous laboratory studies (Holton and Willeke, 1992; Chen et al., 1990; Chen and Willeke, 1992; Balazy et al., 2006a) as well as our recent field study in agricultural environments (Lee et al., 2005b), which have shown that the size of particles affects their…”
BackgroundResultInfluentialLee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500330583 · Cited by 73 · cited 5×
“In some previous investigations, artificial leaks were created on a manikin face to examine the effect of leak shape, leak size and leak location on the particle penetration through face-seal leaks in the size range of about 0.1–5 lm (Chen and Willeke, 1992; Lee et al., 2005a).”
BackgroundMethodSelf-citationSimulated Workplace Performance of N95 Respirators
Coffey, C. C., Campbell, D. L., & Zhuang, Z. (1999) · American Industrial Hygiene Association Journal · doi:10.1080/00028899908984481 · Cited by 69 · cited 1×
“Earlier studies have shown that the protection levels determined using the set of exercises included in the OSHA protocol highly correlated with the actual exposures from a simulated health-care workplace study (Coffey et al., 1999; Lawrence et al., 2006).”
BackgroundFILTER AND LEAK PENETRATION CHARACTERISTICS OF A DUST AND MIST FILTERING FACEPIECE
Chen, C. C., Ruuskanen, J., Pilacinski, W., & Willeke, K. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091370275 · Cited by 53 · cited 1×
“This supports the results of several previous laboratory studies (Holton and Willeke, 1992; Chen et al., 1990; Chen and Willeke, 1992; Balazy et al., 2006a) as well as our recent field study in agricultural environments (Lee et al., 2005b), which have shown that the size of particles affects their…”
ResultSimulated workplace protection factors for half-facepiece respiratory protective devices
Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701346925 · Cited by 52 · cited 2×
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
BackgroundMethod(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meh097 · Cited by 50 · cited 5×
“In some previous investigations, artificial leaks were created on a manikin face to examine the effect of leak shape, leak size and leak location on the particle penetration through face-seal leaks in the size range of about 0.1–5 lm (Chen and Willeke, 1992; Lee et al., 2005a).”
BackgroundMethodSelf-citationErrors Associated with Three Methods of Assessing Respirator Fit
Coffey, C. C., Lawrence, R. B., Zhuang, Z., Duling, M. G., & Campbell, D. L. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500455398 · Cited by 30 · cited 1×
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
MethodThe Effect of Aerosol Size Distribution and Measurement Method on Respirator Fit
Holton, P. M., & Willeke, K. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385705 · Cited by 23 · cited 1×
“This supports the results of several previous laboratory studies (Holton and Willeke, 1992; Chen et al., 1990; Chen and Willeke, 1992; Balazy et al., 2006a) as well as our recent field study in agricultural environments (Lee et al., 2005b), which have shown that the size of particles affects their…”
ResultParticle Settling After Lead-Based Paint Abatement Work and Clearance Waiting Period
Choe, K. T., Trunov, M., Grinshpun, S. A., Willeke, K., Harney, J. M., Trakumas, S., Mainelis, G., Bornschein, R. L., Clark, S., & Friedman, W. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984589 · Cited by 19 · cited 1×
“The experiments were conducted in a walk-in indoor test chamber (Choe et al., 2000).”
MethodSelf-citationWang, W., Sy, C., Ij, L., Chen, Y., Hl, C., Cf, Y., Chen, P., Yeh, S., Kao, C., Huang, L., et al. (2004) · Cited by 14
Lee, S.-A., Reponen, T., Li, W., Trunov, M. A., Willeke, K., & Grinshpun, S. A. (2004) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2004.07.0005 · Cited by 11 · cited 5×
“The original personal sampling system had two sampling lines for measurement of airborne dust and microorganisms inside and outside the N95 filtering facepiece respirator (Lee et al., 2004).”
BackgroundMethodSelf-citationParticle Settling After Lead-Based Paint Abatement Work and Clearance Waiting Period
Choe, K. T., Trunov, M., Grinshpun, S. A., Willeke, K., Harney, J. M., Trakumas, S., Mainelis, G., Bornschein, R. L., Clark, S., & Friedman, W. (2000) · American Industrial Hygiene Association Journal · doi:10.1202/0002-8894(2000)061<0798:psalbp>2.0.co;2 · Cited by 8
Self-citationAerosol Penetration Behavior of Respirator Valves
Brosseau, L. M. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010433 · Cited by 7 · cited 1×
“Aerosol penetration through the exhalation valve was also investigated for half-facepiece negative-pressure respirators by Brosseau (1998), who found that the penetration values were about 0.03–0.04%, indicating no valve failure.”
InfluentialSevere acute respiratory syndrome.
Nassiri, R. (2003) · PubMed · Cited by 1
Research works printed but not linked: 11
- CDC. CDC interim recommendations for protecting workers from exposure to Bacillus anthracis in work sites where mail is handled or processed. Atlanta, Georgia: Centers for Disease Control and Prevention; 2001. [Google Scholar]
- CDC. Interim guidance for cleaning of commercial passenger aircraft following a flight with a passenger with suspected SARS. Atlanta, Georgia: Centers for Disease Control and Prevention; 2003. [Google Scholar]
- CDC. Update on influenza A (H5N1) and SARS: interim recommendations for enhanced U.S. surveillance, testing, and infection controls. Atlanta, Georgia: Centers for Disease Control and Prevention; 2004. [Google Scholar]
- Department of Labor, Occupational Safety and Health Administration. Respiratory protection: 29 CFR 1910.134, appendix A. Washington: Department of Labor, Occupational Safety and Health Administration; 1998. [Google Scholar]
- Department of Labor, Occupational Safety and Health Administration. Federal Register 71:164. Washington: Department of Labor, Occupational Safety and Health Administration; 2006. 29 CFR parts 1910, 1915, and 1926 assigned protection factors; final rule 71:50121–50192. [Google Scholar]
- NIOSH. Federal register 60:110. U.S. Center for Disease Control and Prevention, Cincinnati, OH, National Institute for Occupational Safety and Health; 1995. 42 CFR 84 respiratory protective devices; final rules and notice. [Google Scholar]
- NIOSH. Standard development: program concept for total inward leakage (TIL) performance requirements and test methods. 2004. Available at http://www.cdc.gov/niosh/npptl/standardsdev/til/ Accessed 1 December 2007. [Google Scholar]
- WHO. Hospital infection control guidance for severe acute respiratory syndrome (revised) Switzerland: World Health Organization; 2003. [Google Scholar]
- WHO. WHO global influenza preparedness plan: the role of WHO and recommendations for national measures before and during pandemics. Switzerland: World Health Organization; 2005. [Google Scholar]
- WHO. Cumulative number of confirmed human cases of avian influenza A/(H5N1) reported to WHO. Switzerland: World Health Organization; 2006. [Google Scholar]
- WHO. H5N1 avian influenza: timeline. Switzerland: World Health Organization; 2006. [Google Scholar]
Cited by
Liang, M., Gao, L., Cheng, C., Zhou, Q., Uy, J. P., Heiner, K., & Sun, C. (2020) · Travel Medicine and Infectious Disease · doi:10.1016/j.tmaid.2020.101751 · Cited by 470
“For example, the micropores of N95 masks materials are only 8 μm in diameter, which can effectively prevent the penetration of virions [4,5].”
Aerosol Transmission of Infectious Disease
Jones, R. M., & Brosseau, L. M. (2015) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000448 · Cited by 380
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
“Note also that Lee et al.(17) found that N95 respirators with good fit could recover from faceseal breaks caused by the head and facial movements after their completion.”
BackgroundMethodInfluentialSelf-citationFace masks effectively limit the probability of SARS-CoV-2 transmission
Cheng, Y., Ma, N., Witt, C., Rapp, S., Wild, P. S., Andreae, M. O., Pöschl, U., & Su, H. (2021) · Science · doi:10.1126/science.abg6296 · Cited by 338
COVID-19 Pandemic: Prevention and Protection Measures to Be Adopted at the Workplace
Cirrincione, L., Plescia, F., Ledda, C., Rapisarda, V., Martorana, D., Moldovan, R. E., Theodoridou, K., & Cannizzaro, E. (2020) · Sustainability · doi:10.3390/su12093603 · Cited by 334
“This result is superimposable to that obtained by other studies, which claim that the protection provided by respirators with an N95 facial filter is approximately seven times greater than that of surgical masks [62].”
Result
Metadata
- Authors
- Lee, S.-A., Grinshpun, S. A., & Reponen, T.
- Affiliations
- Feng Chia University (TW)
- University of Cincinnati (US)
- Corresponding author
- Reponen, Tiina
- Venue
- The Annals of Occupational Hygiene
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-03-07
- Volume
- 52
- Issue
- 3
- Pages
- 177-185
- ISSN
- 0003-4878 (ISSN-L)
- 1475-3162
- PMC
- PMC7539566
- OpenAlex
- W1981110022
- Cited by
- 235
- References
- 34
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 12 · 2023: 12 · 2022: 20 · 2021: 40 · 2020: 50 · 2019: 11 · 2018: 5 · 2017: 7 · 2016: 9 · 2015: 9 · 2014: 7 · 2013: 8 · 2012: 13
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- The Annals of Occupational Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01 OH0408501)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, surgical masks, protection factor, respiratory protection, NaCl aerosol, particle size, exhalation valve, breathing resistance, fit testing, filtering facepiece respirators
- MeSH terms
- Bacterial Infections, Equipment Design, Humans, Masks, Materials Testing, Particle Size, Respiratory Protective Devices, Virus Diseases, Occupational Exposure, Infectious Disease Transmission, Vertical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.