The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
In vivo MRI of brain inflammation in human ischaemic stroke
Abstract
Inflammation contributes to brain damage caused by ischaemic stroke. Macrophages, as the prevailing inflammatory cell population in stroke lesions, can be visualized using ultrasmall superparamagnetic iron oxide (USPIO) as a cell-specific contrast agent for MRI. In this single-centre open-labelled clinical phase II study we tested the potential of USPIO-enhanced MRI for macrophage imaging in human ischaemic stroke lesions. In a series of 10 consecutive patients, USPIO contrast agent was infused at the end of the first week after symptom onset. Two follow-up MRI scans were performed 24-36 h and 48-72 h after infusion. Two distinct components of USPIO-related signal changes were discernible, one associated with blood vessels and one representing parenchymal enhancement. Vessel-associated changes appeared as signal loss on T2/T2*-weighted images and decreased from the first to second scan after USPIO infusion, most likely reflecting a transient blood pool effect of the contrast agent. Conversely, parenchymal enhancement was mainly evident on T1-weighted images, increased over time, and matched with the expected distribution of macrophages. Importantly, USPIO-induced signal alterations throughout differed from signatures of conventional gadolinium-enhanced MRI, thus being independent from breakdown of the blood-brain barrier. We suggest that increasing USPIO-enhancement on T1-weighted images indicates brain infiltration by USPIO-laden macrophages. Thus, USPIO-enhanced MRI may provide an in vivo surrogate marker of cellular inflammation in stroke and other CNS pathologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Huitinga, I., van Rooijen, N., de Groot, C. J., Uitdehaag, B. M., & Dijkstra, C. D. (1990) · The Journal of experimental medicine · doi:10.1084/jem.172.4.1025 · Cited by 506
Schilling, M., Besselmann, M., Leonhard, C., Mueller, M., Ringelstein, E. B., & Kiefer, R. (2003) · Experimental Neurology · doi:10.1016/s0014-4886(03)00082-7 · Cited by 375
Cited by
Nanomedicine: current status and future prospects
Moghimi, S. M., Hunter, A. C., & Murray, J. C. (2005) · The FASEB Journal · doi:10.1096/fj.04-2747rev · Cited by 2,029
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Neuroinflammation, Stroke, Blood-Brain Barrier Dysfunction, and Imaging Modalities
Candelario-Jalil, E., Dijkhuizen, R. M., & Magnus, T. (2022) · Stroke · doi:10.1161/strokeaha.122.036946 · Cited by 953
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Neuroinflammation and psychiatric illness
Najjar, S., Pearlman, D. M., Alper, K., Najjar, A., & Devinsky, O. (2013) · Journal of Neuroinflammation · doi:10.1186/1742-2094-10-43 · Cited by 733
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Superparamagnetic iron oxide based MRI contrast agents: Current status of clinical application.
Wáng, Y. X. J. (2011) · PubMed · doi:10.3978/j.issn.2223-4292.2011.08.03 · Cited by 613
Nanoplatforms for Targeted Molecular Imaging in Living Subjects
Cai, W., & Chen, X. (2007) · Small · doi:10.1002/smll.200700351 · Cited by 563
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
Nanoparticles for Brain Drug Delivery
Masserini, M. (2013) · ISRN Biochemistry · doi:10.1155/2013/238428 · Cited by 489
Nanowire Sensors for Medicine and The Life Sciences
Patolsky, F., Zheng, G., & Lieber, C. M. (2006) · Nanomedicine · doi:10.2217/17435889.1.1.51 · Cited by 489
Immune interventions in stroke
Fu, Y., Liu, Q., Anrather, J., & Shi, F.-D. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.144 · Cited by 383
Zipp, F., & Aktas, O. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.006 · Cited by 348
Modo, M., Hoehn, M., & Bulte, J. W. M. (2005) · Molecular Imaging · doi:10.1162/15353500200505145 · Cited by 294
Microglia in ischemic brain injury
Weinstein, J. R., Koerner, I. P., & Möller, T. (2009) · Future Neurology · doi:10.2217/fnl.10.1 · Cited by 272
Inflammation and ischaemic stroke
Muir, K. W., Tyrrell, P., Sattar, N., & Warburton, E. (2007) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32813ba151 · Cited by 264
Reddy, M. K., & Labhasetwar, V. (2009) · The FASEB Journal · doi:10.1096/fj.08-116947 · Cited by 264
Jain, K. K. (2017) · Springer eBooks · doi:10.1007/978-1-4939-6966-1 · Cited by 264
Vellinga, M. M., Oude Engberink, R. D., Seewann, A., Pouwels, P. J. W., Wattjes, M. P., van der Pol, S. M. A., Pering, C., Polman, C. H., de Vries, H. E., Geurts, J. J. G., et al. (2008) · Brain · doi:10.1093/brain/awn009 · Cited by 183
Therapeutics, imaging and toxicity of nanomaterials in the central nervous system.
Nunes, A., Al-Jamal, K. T., & Kostarelos, K. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.03.026 · Cited by 75
Montagne, A., Gauberti, M., Macrez, R., Jullienne, A., Briens, A., Raynaud, J.-S., Louin, G., Buisson, A., Haelewyn, B., Docagne, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.018 · Cited by 70
Metadata
- Authors
- Saleh, A., Schroeter, M., Jonkmanns, C., Hartung, H.-P., Modder, U., & Jander, S.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-05-05
- Volume
- 127
- Issue
- 7
- Pages
- 1670-1677
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- OpenAlex
- W2109030151
- Cited by
- 226
- References
- 3
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.