CoChat

Chemiluminescent measurement of total urinary nitrogen for accurate calculation of nitrogen balance

Skogerboe, K J, Labbé, R F, Rettmer, R L, Sundquist, J P, Gargett, A M · 1990 · Clinical Chemistry
Cited by 39

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This instrumental method for total urinary nitrogen (TUN) is based on the principle of gas-phase chemiluminescence. Results correlate well with measurements of TUN by the Kjeldahl method, which has long provided the means to calculate nitrogen balances for nutritional management. In recent years, because of speed and convenience of measurement, determination of urinary urea nitrogen (UUN) has been substituted for Kjeldahl TUN. However, in patients requiring aggressive nutritional support, the UUN may not be a valid indicator of total nitrogen excretion. We compared nitrogen balances calculated for patients, using both UUN and chemiluminescence TUN data. For both normal and hospitalized populations, nitrogen balance calculated from UUN data exceeded that calculated from TUN data. We show that use of UUN data in calculating nitrogen balance may result in an incorrect assessment of many patients as being in positive nitrogen balance. TUN determined by chemiluminescence evidently provides a simple means of calculating nitrogen balance more nearly accurately.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/36.5.752

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Skogerboe, K. J., Labbé, R. F., Rettmer, R. L., Sundquist, J. P., & Gargett, A. M.
Venue
Clinical Chemistry
Published
1990-05-01
Volume
36
Issue
5
Pages
752-755
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2220887140
Cited by
39
References
1
FWCI
1.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.