A robust approach to reference interval estimation and evaluation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We propose a new methodology for the estimation of reference intervals for data sets with small numbers of observations or for those with substantial numbers of outliers. We propose a prediction interval that uses robust estimates of location and scale. The SAS software can be readily modified to do these calculations. We compared four reference interval procedures (nonparametric, transformed, robust with a nonparametric lower limit, and transformed robust) for sample sizes of 20, 40, 60, 80, 100, and 120 from χ2 distributions of 1, 4, 7, and 10 df. χ2 distributions were chosen because they simulate the skewness of distributions often found in clinical chemistry populations. We used the root mean square error as the measure of performance and used computer simulation to calculate this measure. The robust estimator showed the best performance for small sample sizes. As the sample size increased, the performance values converged. The robust method for calculating upper reference interval values yields reasonable results. In two examples using real data for haptoglobin and glucose, the robust estimator provides slightly smaller upper reference limits than the other procedures. Lastly, the robust estimator was compared with the other procedures in a population where 5% of the values were multiplied by a factor of 5. The reference intervals were calculated with and without outlier detection. In this case, the robust approach consistently yielded upper reference interval values that were closer to those of the true underlying distributions. We propose that robust statistical analysis can be of great use for determinations of reference intervals from limited or possibly unreliable data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Analysis of Transformations
Box, G. E. P., & Cox, D. R. (1964) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1964.tb00553.x · Cited by 15,052
The Jackknife, the Bootstrap and Other Resampling Plans
Efron, B. (1982) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970319 · Cited by 8,120
A new distribution-free quantile estimator
HARRELL, F. E., & DAVIS, C. E. (1982) · Biometrika · doi:10.1093/biomet/69.3.635 · Cited by 546
Statistical Bases of Reference Values in Laboratory Medicine
Harris, E. K., & Boyd, J. C. (1995) · CRC Press eBooks · doi:10.1201/9781482273151 · Cited by 232
International federation of clinical chemistry
Pannall, P. R., Marshall, W., Jabor, A., & Magid, E. (1996) · Clinica Chimica Acta · doi:10.1016/0009-8981(95)06205-x · Cited by 155
A Biweight Approach to the One-Sample Problem
Kafadar, K. (1982) · Journal of the American Statistical Association · doi:10.1080/01621459.1982.10477827 · Cited by 105
Two-stage transformation systems for normalization of reference distributions evaluated.
Línnet, K. (1987) · Clinical Chemistry · doi:10.1093/clinchem/33.3.381 · Cited by 94
A multi-stage Gaussian transformation algorithm for clinical laboratory data.
Boyd, J. C., & Lacher, D. A. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.8.1735 · Cited by 41
A Biweight Prediction Interval for Random Samples
Horn, P. S. (1988) · Journal of the American Statistical Association · doi:10.1080/01621459.1988.10478593 · Cited by 27
Self-citation
Cited by
Friedrichs, K. R., Harr, K. E., Freeman, K. P., Szladovits, B., Walton, R. M., Barnhart, K. F., & Blanco‐Chavez, J. (2012) · Veterinary Clinical Pathology · doi:10.1111/vcp.12006 · Cited by 1,293
Geffré, A., Concordet, D., Braun, J., & Trumel, C. (2011) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2011.00287.x · Cited by 582
(2021) · Elsevier eBooks · doi:10.1016/c2018-0-03395-2 · Cited by 467
Reference intervals: an update
Horn, P. S., & Pesce, A. J. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00133-5 · Cited by 412
Self-citationIndirect methods for reference interval determination – review and recommendations
Jones, G. R. D., Haeckel, R., Loh, T. P., Sikaris, K., Streichert, T., Katayev, A., Barth, J. H., & Ozarda, Y. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0073 · Cited by 349
Geffré, A., Friedrichs, K., Harr, K., Concordet, D., Trumel, C., & Braun, J. (2009) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2009.00179.x · Cited by 348
Henderson, A. R. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.04.002 · Cited by 319
The Canadian laboratory initiative on pediatric reference intervals: A CALIPER white paper
Adeli, K., Higgins, V., Trajcevski, K., & White-Al Habeeb, N. (2017) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2017.1379945 · Cited by 303
Effect of Outliers and Nonhealthy Individuals on Reference Interval Estimation
Horn, P. S., Feng, L., Li, Y., & Pesce, A. J. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.12.2137 · Cited by 301
Self-citationKushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.143222 · Cited by 283
Reference intervals: current status, recent developments and future considerations
Ozarda, Y. (2016) · Biochemia Medica · doi:10.11613/bm.2016.001 · Cited by 264
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Wolfger, B., Schwartzkopf-Genswein, K. S., Barkema, H. W., Pajor, E. A., Levy, M., & Orsel, K. (2015) · Journal of Animal Science · doi:10.2527/jas.2013-8030 · Cited by 70
Kulasingam, V., Jung, B. P., Blasutig, I. M., Baradaran, S., Chan, M. K., Aytekin, M., Colantonio, D. A., & Adeli, K. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.05.008 · Cited by 58
Hill, J. S., Devenie, G., & Powell, M. (2012) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1204000612 · Cited by 50
Comparing Ethnicity-Specific Reference Intervals for Clinical Laboratory Tests from EHR Data
Rappoport, N., Paik, H., Oskotsky, B., Tor, R., Ziv, E., Zaitlen, N., & Butte, A. J. (2018) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.026492 · Cited by 49
“However, reference samples are dif fi cult to obtain, laboratories often use “easily collected” samples such as college students or internal laboratory staff ( 7 ), or rely on reference intervals from the literature or analytical instrument manufacturer product inserts ( 3 ).”
BackgroundPediatric reference values for serum magnesium levels in Iranian subjects
Ghasemi, A., Syedmoradi, L., Zahediasl, S., & Azizi, F. (2010) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2010.504280 · Cited by 13
Metadata
- Authors
- Horn, P. S., Pesce, A. J., & Copeland, B. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-03-01
- Volume
- 44
- Issue
- 3
- Pages
- 622-631
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1912628347
- Cited by
- 272
- References
- 9
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.