Design of a Biosensor for Continual, Transdermal Glucose Monitoring
Open accessThe DOI matches its Crossref record.
Abstract
The Diabetes Control and Complications Trial (1) and other trials have shown that frequent monitoring of blood glucose by diabetics is critical to achieving normoglycemic concentrations. The ability to achieve this goal is hampered, however, by the lack of any means of obtaining frequent blood glucose data in a convenient and unobtrusive manner. To address these needs, a continual, noninvasive glucose monitoring system has been developed that utilizes reverse iontophoresis to induce an electroosmotic flux of glucose through intact skin. The electroosmotic glucose flux (measured ex vivo by HPLC) was shown in earlier clinical trials to correlate with the blood glucose concentrations (2). To create a miniaturized and wearable system, an amperometric biosensor has been developed that measures in situ the glucose extracted through the skin into a hydrogel pad to provide periodic measures of blood glucose every 20 min over the course of 12 h. A diagram of this system is shown in Fig. 1 A. Schematic of the GlucoWatch biographer (A) and evaluation of stability of glucose extraction and measurement in cadaver skin diffusion cell over 12 h (36 measurements) at 500, 1000, and 4000 mg/L (50, 100, and 400 mg/dL; B). A major advancement that has been achieved in the development of this biosensor is the ability to accurately measure the small amounts of glucose that are extracted through the skin. These glucose concentrations are several orders of magnitude lower than those present in the blood (∼5 μmol/L vs ∼5 mmol/L), representing a total amount of glucose in the 50–200 picomol range. The main design criteria are summarized below. The small amount of glucose extracted requires a biosensor with a detection limit much lower than conventional devices attain. A low detection limit has been achieved through the use of a large surface area working electrode and the development of a screen-printable platinum-graphite composite electrode material with high sensitivity and low background current. The large electrode, coupled with coulometric measurements, allows detection of a large fraction of the glucose collected into the hydrogel pad every cycle. The characteristics of the biosensor were investigated in an in vitro cadaver skin diffusion cell thermostated at 32 °C. This cell consists of a donor solution compartment separated from the biosensor/iontophoresis assembly by a layer of heat-separated human epidermis. This test mimics very closely the in vivo performance of both the iontophoresis and biosensor functions. In this test, the integrated biosensor current responded linearly when the glucose concentration in the donor solution was increased stepwise through the range from 0 to 5000 mg/L (0 to 500 mg/dL) glucose [mean correlation coefficient (r) over six separate systems, 0.992; range, 0.965–0.999]. The continual, periodic measurement cycle requires that the sensing be completed and that the previously extracted glucose be depleted for the next iontophoresis cycle to begin anew. Each measurement cycle is made up of two half-cycles, each consisting of 3 min of iontophoresis and 7 min of biosensing. The polarity of the iontophoretic current alternates for each half-cycle. The sensor geometry, diffusion distances through the hydrogel pad, glucose oxidase enzyme kinetics, glucose mutarotation kinetics, and electron transfer kinetics on the electrode all affect the dynamics of the measurement cycle. These parameters have been co-optimized using computer modeling (3) to achieve high sensitivity glucose measurement and subsequent depletion of remaining glucose within the required time period. The sensitivity of the system must be stable to make repeated measurements over 12 h. Stability was investigated in nine separate in vitro diffusion cell systems. Each system was calibrated at the beginning of the measurement period to account for skin flux differences and the usual variances in the sensitivity of the biosensor. Three systems each were stepped to glucose concentrations of 500, 1000, and 4000 mg/L (50, 100, and 400 mg/dL), and the stability was evaluated over 36 measurements over the course of 12 h (Fig. 1B). The stability, as measured by the mean CV for the three cells at each concentration was 7.7%, 5.2%, and 5.1% for 500, 1000, and 4000 mg/L concentrations, respectively. The biosensor has low sensitivity to most potential interfering species. This selectivity was achieved by utilizing the inherent permselective properties of the skin and the electroosmotic extraction process. The extraction through skin provides both size- and charge-exclusion properties. The size-exclusion properties arise from the molecular weight cutoff of ∼500 for efficient extraction of compounds through the skin (4). The charge-exclusion properties are caused by the net negative charge carried by skin at physiological pH (5). Because of this charge, the electroosmotic flux, which carries the glucose, flows predominantly toward the iontophoretic cath
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Biosensors--Sense and Sensitivity
Turner, A. P. F. (2000) · Science · doi:10.1126/science.290.5495.1315 · Cited by 524
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
“Some examples are iontophoretic extraction of glucose through the skin (Tierney et al., 1999), visible (Yeh et al.”
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Research and development in biosensors
Scheller, F. W., Wollenberger, U., Warsinke, A., & Lisdat, F. (2001) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(00)00169-5 · Cited by 267
Glucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
“The biosensor chemistry utilises direct detection of H2O2 generated from the oxidation of glucose by glucose oxidase [4].”
MethodTransdermal iontophoresis: combination strategies to improve transdermal iontophoretic drug delivery
Wang, Y., Thakur, R., Fan, Q., & Michniak, B. (2005) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.12.008 · Cited by 236
Xia, Y., Huang, W., Zheng, J., Niu, Z., & Li, Z. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.044 · Cited by 186
“Glucose biosensors with such a low etection limit have potential applications in noninvasive glucose evices (Tierney et al., 1999, 2001; Potts et al., 2002; Newman ig.”
BackgroundMiniature Biofuel Cell as a Potential Power Source for Glucose-Sensing Contact Lenses
Falk, M., Andoralov, V., Silow, M., Toscano, M. D., & Shleev, S. (2013) · Analytical Chemistry · doi:10.1021/ac4006793 · Cited by 173
Metadata
- Authors
- Tierney, M. J., Jayalakshmi, Y., Parris, N. A., Reidy, M. P., Uhegbu, C., & Vijayakumar, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-09-01
- Volume
- 45
- Issue
- 9
- Pages
- 1681-1683
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2136164922
- Cited by
- 59
- References
- 0
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.