The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
MIQE 2.0: Revision of the Minimum Information for Publication of Quantitative Real-Time PCR Experiments Guidelines
Open accessAbstract
Background: In 2009, the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines established standards for the design, execution, and reporting of quantitative PCR (qPCR) in research. The expansion of qPCR into numerous new domains has driven the development of new reagents, methods, consumables, and instruments, requiring revisions to best practices that are tailored to the evolving complexities of contemporary qPCR applications. Content: Transparent, clear, and comprehensive description and reporting of all experimental details are necessary to ensure the repeatability and reproducibility of qPCR results. These revised MIQE guidelines reflect recent advances in qPCR technology, offering clear recommendations for sample handling, assay design, and validation, along with guidance on qPCR data analysis. Instrument manufacturers are encouraged to enable the export of raw data to facilitate thorough analyses and re-evaluation by manuscript reviewers and interested researchers. The guidelines emphasize that quantification cycle (Cq) values should be converted into efficiency-corrected target quantities and reported with prediction intervals, along with detection limits and dynamic ranges for each target, based on the chosen quantification method. Additionally, best practices for normalization and quality control are outlined and reporting requirements have been clarified and streamlined. The aim is to encourage researchers to provide all necessary information without undue burden, thereby promoting more rigorous and reproducible qPCR research. Summary: Building on the collaborative efforts of an international team of researchers, we present updates, simplifications, and new recommendations to the original MIQE guidelines, designed to maintain their relevance and applicability in the context of emerging technologies and evolving qPCR applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Self-citationVandesompele, J., De Preter, K., Pattyn, F., Poppe, B., Van Roy, N., De Paepe, A., & Speleman, F. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-research0034 · Cited by 20,038
Self-citationThe MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationHellemans, J., Mortier, G., De Paepe, A., Speleman, F., & Vandesompele, J. (2007) · Genome Biology · doi:10.1186/gb-2007-8-2-r19 · Cited by 4,023
Self-citationAssumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709
Self-citationAmplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
Self-citationQuantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247
Self-citationThe real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Self-citationRNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Self-citationComprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303
Simultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G., Walsh, P. S., & Griffith, R. (1992) · Bio/Technology · doi:10.1038/nbt0492-413 · Cited by 1,130
A novel and universal method for microRNA RT-qPCR data normalization
Mestdagh, P., Van Vlierberghe, P., De Weer, A., Muth, D., Westermann, F., Speleman, F., & Vandesompele, J. (2009) · Genome Biology · doi:10.1186/gb-2009-10-6-r64 · Cited by 1,079
Self-citationSEQC/MAQC-III Consortium (2014) · Nature Biotechnology · doi:10.1038/nbt.2957 · Cited by 983 · cited 1×
“Using 5 ng of RNA equivalents (170 to 500 transcriptome equivalents) is generally sufficient to quantify most mammalian transcripts, although rare transcripts in plant and environmental testing will have different requirements and can require significantly more nucleic acid (47).”
A standard curve based method for relative real time PCR data processing
Larionov, A., Krause, A., & Miller, W. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-62 · Cited by 946
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859 · cited 1×
“This rapid pace of technological advancement requires updates to the MIQE guidelines to ensure they continue to reflect best practices, much like the updated digital MIQE guidelines (22, 23).”
Self-citationThe Ultimate qPCR Experiment: Producing Publication Quality, Reproducible Data the First Time
Taylor, S. C., Nadeau, K., Abbasi, M., Lachance, C., Nguyen, M., & Fenrich, J. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.12.002 · Cited by 830
Dheda, K., Huggett, J. F., Chang, J. S., Kim, L. U., Bustin, S. A., Johnson, M. A., Rook, G. A. W., & Zumla, A. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.05.022 · Cited by 668
Self-citationTricarico, C., Pinzani, P., Bianchi, S., Paglierani, M., Distante, V., Pazzagli, M., Bustin, S. A., & Orlando, C. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00311-1 · Cited by 581
Self-citationForootan, A., Sjöback, R., Björkman, J., Sjögreen, B., Linz, L., & Kubista, M. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.04.001 · Cited by 578
Self-citationThe dMIQE Group, Whale, A. S., De Spiegelaere, W., Trypsteen, W., Nour, A. A., Bae, Y.-K., Benes, V., Burke, D., Cleveland, M., Corbisier, P., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa125 · Cited by 516
Self-citationComplexities of Viral Mutation Rates
Peck, K. M., & Lauring, A. S. (2018) · Journal of Virology · doi:10.1128/jvi.01031-17 · Cited by 442
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409 · cited 1×
“Both are affected by the quality and quantity of RNA input (52), secondary structure and pa-lindromes, priming method (53, 54), reverse transcriptase enzyme (29, 53, 55), and reaction conditions.”
Self-citationBengtsson, M., Ståhlberg, A., Rorsman, P., & Kubista, M. (2005) · Genome Research · doi:10.1101/gr.3820805 · Cited by 392
Self-citationBustin, S., & Huggett, J. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.11.001 · Cited by 312
Self-citationMicroRNA Detection Specificity: Recent Advances and Future Perspective
Ouyang, T., Liu, Z., Han, Z., & Ge, Q. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05909 · Cited by 296
The need for transparency and good practices in the qPCR literature
Bustin, S. A., Benes, V., Garson, J., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2697 · Cited by 281
Self-citationHighly multiplexed and strand-specific single-cell RNA 5′ end sequencing
Islam, S., Kjällquist, U., Moliner, A., Zajac, P., Fan, J.-B., Lönnerberg, P., & Linnarsson, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.022 · Cited by 272
Ruijter, J. M., Pfaffl, M. W., Zhao, S., Spiess, A. N., Boggy, G., Blom, J., Rutledge, R. G., Sisti, D., Lievens, A., De Preter, K., et al. (2013) · Methods · doi:10.1016/j.ymeth.2012.08.011 · Cited by 258
Self-citationDwight, Z., Palais, R., & Wittwer, C. T. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr065 · Cited by 256
Self-citationComparison of Reverse Transcriptases in Gene Expression Analysis
Ståhlberg, A., Kubista, M., & Pfaffl, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.035469 · Cited by 240
Self-citationBrankatschk, R., Bodenhausen, N., Zeyer, J., & Bürgmann, H. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07878-11 · Cited by 226
Smith, C. J., Nedwell, D. B., Dong, L. F., & Osborn, A. M. (2006) · Environmental Microbiology · doi:10.1111/j.1462-2920.2005.00963.x · Cited by 221
Rutledge, R. G., & Stewart, D. (2008) · BMC Biotechnology · doi:10.1186/1472-6750-8-47 · Cited by 209
Extreme PCR: Efficient and Specific DNA Amplification in 15–60 Seconds
Farrar, J. S., & Wittwer, C. T. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2014.228304 · Cited by 202
Self-citationSingle-Nucleotide Polymorphisms and Other Mismatches Reduce Performance of Quantitative PCR Assays
Lefever, S., Pattyn, F., Hellemans, J., & Vandesompele, J. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.203653 · Cited by 200
Self-citationTwo-tailed RT-qPCR: a novel method for highly accurate miRNA quantification
Androvic, P., Valihrach, L., Elling, J., Sjoback, R., & Kubista, M. (2017) · Nucleic Acids Research · doi:10.1093/nar/gkx588 · Cited by 198
Self-citationUntergasser, A., Ruijter, J. M., Beneš, V., & van den Hoff, M. J. B. (2021) · BMC Bioinformatics · doi:10.1186/s12859-021-04306-1 · Cited by 182
Self-citationAmplification of nonspecific products in quantitative polymerase chain reactions (qPCR)
Ruiz‐Villalba, A., van Pelt-Verkuil, E., Gunst, Q. D., Ruijter, J. M., & van den Hoff, M. J. B. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.10.001 · Cited by 175
Self-citationHighly accurate sigmoidal fitting of real-time PCR data by introducing a parameter for asymmetry
Spiess, A.-N., Feig, C., & Ritz, C. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-221 · Cited by 167
RDML: structured language and reporting guidelines for real-time quantitative PCR data
Lefever, S., Hellemans, J., Pattyn, F., Przybylski, D. R., Taylor, C., Geurts, R., Untergasser, A., Vandesompele, J., & on behalf of the RDML consortium (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp056 · Cited by 165
Self-citationUse and Misuse of Cq in qPCR Data Analysis and Reporting
Ruiz‐Villalba, A., Ruijter, J. M., & van den Hoff, M. J. B. (2021) · Life · doi:10.3390/life11060496 · Cited by 161
Self-citationEfficiency Correction Is Required for Accurate Quantitative PCR Analysis and Reporting
Ruijter, J. M., Barnewall, R., Marsh, I. B., Szentirmay, A. N., Quinn, J. C., van Houdt, R., Gunst, Q. D., & van den Hoff, M. J. B. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab052 · Cited by 153
Self-citationSelection of Reliable Reference Genes for RT-qPCR Analysis
Hellemans, J., & Vandesompele, J. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-0733-5_3 · Cited by 140
Self-citationBivins, A. W., Kaya, D., Bibby, K. J., Simpson, S. L., Bustin, S. A., Shanks, O. C., & Ahmed, W. (2021) · Water Research · doi:10.1016/j.watres.2021.117516 · Cited by 137
Self-citationCorrection of RT–qPCR data for genomic DNA-derived signals with ValidPrime
Laurell, H., Iacovoni, J. S., Abot, A., Švec, D., Maoret, J.-J., Arnal, J., & Kubista, M. (2012) · Nucleic Acids Research · doi:10.1093/nar/gkr1259 · Cited by 125
Self-citationData-driven normalization strategies for high-throughput quantitative RT-PCR
Mar, J. C., Kimura, Y., Schroder, K., Irvine, K. M., Hayashizaki, Y., Suzuki, H., Hume, D. A., & Quackenbush, J. F. (2009) · BMC Bioinformatics · doi:10.1186/1471-2105-10-110 · Cited by 124
Sanders, R., Mason, D. J., Foy, C. A., & Huggett, J. F. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7857-x · Cited by 123
Self-citationPCR inhibition by reverse transcriptase leads to an overestimation of amplification efficiency
Suslov, O. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni176 · Cited by 121 · cited 1×
“Too much RNA, on the other hand, can result in inaccurate quantification of some transcripts (58).”
Bustin, S., & Nolan, T. (2017) · European Journal of Clinical Investigation · doi:10.1111/eci.12801 · Cited by 113 · cited 1×
“RT-qPCR and qPCR experiments are susceptible to variability and errors that fall into three main categories: biological, protocol, and technical (10, 25, 26).”
Self-citationDesign and Optimization of Reverse-Transcription Quantitative PCR Experiments
Tichopád, A., Kitchen, R., Riedmaier, I., Becker, C., Ståhlberg, A., & Kubista, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.126201 · Cited by 113
Self-citationStepwise Optimization of Real-Time RT-PCR Analysis
Maren, N. A., Duduit, J. R., Huang, D., Zhao, F., Ranney, T. G., & Liu, W. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3131-7_20 · Cited by 107
Variability of the Reverse Transcription Step: Practical Implications
Bustin, S. A., Dhillon, H. S., Kirvell, S. L., Greenwood, C., Parker, M. J., Shipley, G. L., & Nolan, T. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2014.230615 · Cited by 101
Self-citationTerpe, K. (2013) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-5290-2 · Cited by 96
Lévesque-Sergerie, J.-P., Duquette, M., Thibault, C., Delbecchi, L., & Bissonnette, N. (2007) · BMC Molecular Biology · doi:10.1186/1471-2199-8-93 · Cited by 94
Parameters for Successful PCR Primer Design
Bustin, S. A., Mueller, R. D., & Nolan, T. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9833-3_2 · Cited by 92
Self-citationLübke, N., Senff, T., Scherger, S., Hauka, S., Andrée, M., Adams, O., Timm, J., & Walker, A. (2020) · Journal of Clinical Virology · doi:10.1016/j.jcv.2020.104579 · Cited by 92
RT-qPCR work-flow for single-cell data analysis
Ståhlberg, A., Rusnakova, V., Forootan, A., Anděrová, M., & Kubista, M. (2012) · Methods · doi:10.1016/j.ymeth.2012.09.007 · Cited by 91
Self-citationImpact of Long-Term Storage on Stability of Standard DNA for Nucleic Acid-Based Methods
Röder, B., Frühwirth, K., Vogl, C., Wagner, M., & Rossmanith, P. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.01230-10 · Cited by 88
DNA polymerase preference determines PCR priming efficiency
Pan, W., Byrne-Steele, M. L., Wang, C., Lu, S., Clemmons, S., Zahorchak, R. J., & Han, J. (2014) · BMC Biotechnology · doi:10.1186/1472-6750-14-10 · Cited by 84
Ruijter, J. M., Lorenz, P., Tuomi, J. M., Hecker, M., & van den Hoff, M. J. B. (2014) · Microchimica Acta · doi:10.1007/s00604-013-1155-8 · Cited by 83
Self-citationWhite, H., Deprez, L., Corbisier, P., Hall, V., Lin, F., Mazoua, S., Trapmann, S., Aggerholm, A., Andrikovics, H., Akiki, S. J., et al. (2014) · Leukemia · doi:10.1038/leu.2014.217 · Cited by 79
Statistical aspects of quantitative real-time PCR experiment design
Kitchen, R. R., Kubista, M., & Tichopád, A. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.025 · Cited by 77
Self-citationImproving the quality of quantitative polymerase chain reaction experiments: 15 years of MIQE
Bustin, S. A. (2024) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2024.101249 · Cited by 73
Self-citationAccurate RT-qPCR gene expression analysis on cell culture lysates
Peer, G. V., Mestdagh, P., & Vandesompele, J. (2012) · Scientific Reports · doi:10.1038/srep00222 · Cited by 70
Self-citationFaster quantitative real-time PCR protocols may lose sensitivity and show increased variability
Hilscher, C., Vahrson, W., & Dittmer, D. P. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni181 · Cited by 70
Storage and shipping of tissue samples for DNA analyses: A case study on earthworms
Straube, D., & Juen, A. (2013) · European Journal of Soil Biology · doi:10.1016/j.ejsobi.2013.04.001 · Cited by 64
Tellinghuisen, J., & Spiess, A. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.12.020 · Cited by 64
Dijkstra, J. R., van Kempen, L. C., Nagtegaal, I. D., & Bustin, S. A. (2014) · Molecular Oncology · doi:10.1016/j.molonc.2013.12.016 · Cited by 59
Self-citationQuality control for quantitative PCR based on amplification compatibility test
Tichopád, A., Bar, T., Pecen, L., Kitchen, R. R., Kubista, M., & Pfaffl, M. W. (2010) · Methods · doi:10.1016/j.ymeth.2010.01.028 · Cited by 58
Self-citationStandardisation and reporting for nucleic acid quantification
Huggett, J. F., & Bustin, S. A. (2011) · Accreditation and Quality Assurance · doi:10.1007/s00769-011-0769-y · Cited by 55
Self-citationHays, A. L., Wissel, M., Colletti, K. S., Soon, R. K., Azadeh, M., Smith, J. S., Doddareddy, R., Chalfant, M., Adamowicz, W. O., Ramaswamy, S. S., et al. (2024) · The AAPS Journal · doi:10.1208/s12248-023-00880-9 · Cited by 55
Self-citationPredicting failure rate of PCR in large genomes
Andreson, R., Möls, T., & Remm, M. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn290 · Cited by 52
Miranda, J. A., & Steward, G. F. (2016) · Journal of Virological Methods · doi:10.1016/j.jviromet.2016.12.002 · Cited by 46
Biophysical, Molecular and Proteomic Profiling of Human Retinal Organoid-Derived Exosomes
Arthur, P., Kandoi, S., Sun, L. J., Kalvala, A. K., Kutlehria, S., Bhattacharya, S., Kulkarni, T., Nimma, R., Li, Y., Lamba, D. A., et al. (2022) · Pharmaceutical Research · doi:10.1007/s11095-022-03350-7 · Cited by 44
Parra, M. P., Jung, J., Boone, T. D., Tran, L. H., Blaber, E. A., Brown, M. J., Chin, M., Chinn, T. N., Cohen, J., Doebler, R. W., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0183480 · Cited by 43
Improving the standardization of mRNA measurement by RT-qPCR
Sanders, R., Bustin, S. A., Huggett, J. F., & Mason, D. J. (2018) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2018.03.001 · Cited by 41
Self-citationWittwer, C. T., Hemmert, A., Kent, J., & Rejali, N. A. (2024) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2024.101268 · Cited by 41
Self-citationBabel, M., Mamilos, A., Seitz, S., Niedermair, T., Weber, F., Anzeneder, T., Ortmann, O., Dietmaier, W., & Brochhausen, C. (2020) · Scientific Reports · doi:10.1038/s41598-020-71441-9 · Cited by 39
Monitoring long-term DNA storage via absolute copy number quantification by ddPCR
Wang, Y., Keith, M., Leyme, A., Bergelson, S., & Feschenko, M. S. (2019) · Analytical Biochemistry · doi:10.1016/j.ab.2019.113363 · Cited by 37
Dumke, R., & Jacobs, E. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.01989-08 · Cited by 36
Multiple freeze-thaw cycles lead to a loss of consistency in poly(A)-enriched RNA sequencing
Kellman, B. P., Baghdassarian, H., Pramparo, T., Shamie, I., Gazestani, V., Begzati, A., Li, S., Nalabolu, S. R., Murray, S. S., Lopez, L., et al. (2021) · BMC Genomics · doi:10.1186/s12864-021-07381-z · Cited by 36
Removal of artifact bias from qPCR results using DNA melting curve analysis
Ruijter, J. M., Ruiz‐Villalba, A., van den Hoff, A. J. J., Gunst, Q. D., Wittwer, C. T., & van den Hoff, M. J. B. (2019) · The FASEB Journal · doi:10.1096/fj.201901604r · Cited by 32
Self-citationShape based kinetic outlier detection in real-time PCR
Sisti, D., Guescini, M., Rocchi, M., Tibollo, P., D’Atri, M., & Stocchi, V. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-186 · Cited by 29
Utilization of Digital PCR in Quantity Verification of Plasmid Standards Used in Quantitative PCR
Beinhauerová, M., Babák, V., Bertasi, B., Boniotti, M. B., & Králík, P. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00155 · Cited by 28
Quantitative Real-Time PCR in aDNA Research
Bunce, M., Oskam, C. L., & Allentoft, M. E. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-516-9_16 · Cited by 26
Validating Real-Time Polymerase Chain Reaction (PCR) Assays
Smith, M. H. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-814515-9.00053-9 · Cited by 26
Development of SARS-CoV-2 packaged RNA reference material for nucleic acid testing
Lee, S., Kim, S., Yoo, H. M., Lee, D.-H., & Bae, Y. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03846-y · Cited by 21
Lindén, J., Ranta, J., & Pohjanvirta, R. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.06.010 · Cited by 20
Kralj, J. G., & Salit, M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6445-1 · Cited by 12
Disclosing quantitative RT‐PCR raw data during manuscript submission: a call for action
Untergasser, A., Hellemans, J., Pfaffl, M. W., Ruijter, J. M., van den Hoff, M. J. B., Dragomir, M. P., Adamóski, D., Dias, S. M. G., Reis, R. M., Ferracin, M., et al. (2023) · Molecular Oncology · doi:10.1002/1878-0261.13418 · Cited by 10
Self-citationImpact of Sample Processing and Storage Conditions on RNA Quality of Fresh-Frozen Cancer Tissues
Chen, Y., Han, Q.-Y., Chen, Q.-Y., Zhou, W., Zhang, J., Zhang, X., & Lin, A. (2023) · Biopreservation and Biobanking · doi:10.1089/bio.2022.0069 · Cited by 8
In silico tools for qPCR assay design and data analysis.
Bustin, S., Bergkvist, A., & Nolan, T. (2011) · Methods in molecular biology · doi:10.1007/978-1-61779-176-5_18 · Cited by 7
Self-citationDirect lysis of 3D cell cultures for RT-qPCR gene expression quantification
Gysens, F., Ostyn, L., Goeteyn, E., Blondeel, E., Nuytens, J., Wever, O. D., de Bony, E. J., Crabbé, A., & Mestdagh, P. (2023) · Scientific Reports · doi:10.1038/s41598-023-28844-1 · Cited by 5
Metadata
- Authors
- Bustin, S. A., Ruijter, J. M., van den Hoff, M. J. B., Kubista, M., Pfaffl, M. W., Shipley, G. L., Tran, N., Rödiger, S., Untergasser, A., Mueller, R., Nolan, T., Milavec, M., Burns, M. J., Huggett, J. F., Vandesompele, J., & Wittwer, C. T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2025-04-24
- Volume
- 71
- Issue
- 6
- Pages
- 634-651
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W4409736934
- Cited by
- 296
- References
- 94
- FWCI
- 75.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.