Bioresorbable scaffolds: rationale, current status, challenges, and future
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Current generation of drug-eluting stents has significantly improved the outcomes of percutaneous coronary intervention by substantially reducing in-stent restenosis and stent thrombosis. However, a potential limitation of these stents is the permanent presence of a metallic foreign body within the artery, which may cause vascular inflammation, restenosis, thrombosis, and neoatherosclerosis. The permanent stents also indefinitely impair the physiological vasomotor function of the vessel and future potential of grafting the stented segment. Bioresorbable scaffolds (BRSs) have the potential to overcome these limitations as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage and restoring pulsatility, cyclical strain, physiological shear stress, and mechanotransduction. While a number of BRSs are under development, two devices with substantial clinical data have already received a Conformité Européenne marking. This review article presents the current status of these devices and evaluates the challenges that need to be overcome before BRSs can become the workhorse device in coronary intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationA Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979) · New England Journal of Medicine · doi:10.1056/nejm197907123010201 · Cited by 2,419
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Self-citationTRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSIS
Grüntzig, A. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90500-7 · Cited by 1,343
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Long-Term Outcomes with Drug-Eluting Stents versus Bare-Metal Stents in Sweden
Lagerqvist, B., James, S. K., Stenestrand, U., Lindbäck, J., Nilsson, T., & Wallentin, L. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067722 · Cited by 1,197
Cited by
Toughening of photo-curable polymer networks: a review
Ligon-Auer, S. C., Schwentenwein, M., Gorsche, C., Stampfl, J., & Liska, R. (2016) · Polymer Chemistry · doi:10.1039/c5py01631b · Cited by 447
Cassese, S., Byrne, R. A., Ndrepepa, G., Kufner, S., Wiebe, J., Repp, J., Schunkert, H., Fusaro, M., Kimura, T., & Kastrati, A. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00979-4 · Cited by 369
Haude, M., Ince, H., Abizaid, A., Toelg, R., Lemos, P. A., von Birgelen, C., Christiansen, E. H., Wijns, W., Neumann, F.-J., Kaiser, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00447-x · Cited by 349
Self-citationFully bioresorbable vascular scaffolds: lessons learned and future directions
Jinnouchi, H., Torii, S., Sakamoto, A., Kolodgie, F. D., Virmani, R., & Finn, A. V. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0124-7 · Cited by 228
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Haude, M., Ince, H., Abizaid, A., Toelg, R., Lemos, P. A., von Birgelen, C., Christiansen, E. H., Wijns, W., Neumann, F.-J., Kaiser, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw196 · Cited by 189
“Bioresorbable scaffolds (BRS) have been designed to overcome problems related to the long-term persistence of metallic stents implanted in coronary arteries.(1,2) Several randomized controlled trials (RCTs) comparing polymeric BRS with new-generation drug-eluting stents (DES) found similar clinical outcomes at 1 year.”
Self-citationAdvances in coatings on magnesium alloys for cardiovascular stents – A review
Zhang, Z.-Q., Yang, Y.-X., Li, J.-A., Zeng, R.-C., & Guan, S.-K. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.04.044 · Cited by 173
Biodegradable stents for coronary artery disease treatment: Recent advances and future perspectives
Hu, T., Yang, C., Lin, S., Yu, Q., & Wang, G. (2018) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.04.100 · Cited by 163
Bioresorbable Scaffold: The Emerging Reality and Future Directions
Sotomi, Y., Onuma, Y., Collet, C., Tenekecioglu, E., Virmani, R., Kleiman, N. S., & Serruys, P. W. (2017) · Circulation Research · doi:10.1161/circresaha.117.310275 · Cited by 162
Self-citationBioresorbable Stents: Is This Where We Are Headed?
Wayangankar, S. A., & Ellis, S. G. (2015) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2015.08.011 · Cited by 18
Metadata
- Authors
- Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-23
- Volume
- 35
- Issue
- 12
- Pages
- 765-776
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2165754633
- Cited by
- 269
- References
- 56
- FWCI
- 29.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.