Bioresorbable scaffolds: rationale, current status, challenges, and future
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Current generation of drug-eluting stents has significantly improved the outcomes of percutaneous coronary intervention by substantially reducing in-stent restenosis and stent thrombosis. However, a potential limitation of these stents is the permanent presence of a metallic foreign body within the artery, which may cause vascular inflammation, restenosis, thrombosis, and neoatherosclerosis. The permanent stents also indefinitely impair the physiological vasomotor function of the vessel and future potential of grafting the stented segment. Bioresorbable scaffolds (BRSs) have the potential to overcome these limitations as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage and restoring pulsatility, cyclical strain, physiological shear stress, and mechanotransduction. While a number of BRSs are under development, two devices with substantial clinical data have already received a Conformité Européenne marking. This review article presents the current status of these devices and evaluates the challenges that need to be overcome before BRSs can become the workhorse device in coronary intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Self-citationFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationA Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Nonoperative Dilatation of Coronary-Artery Stenosis: Percutaneous Transluminal Coronary Angioplasty
Grüntzig, A. R., Senning, Å., & Siegenthaler, W. E. (1979) · New England Journal of Medicine · doi:10.1056/nejm197907123010201 · Cited by 2,419
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Self-citationTRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSIS
Grüntzig, A. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90500-7 · Cited by 1,343
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Long-Term Outcomes with Drug-Eluting Stents versus Bare-Metal Stents in Sweden
Lagerqvist, B., James, S. K., Stenestrand, U., Lindbäck, J., Nilsson, T., & Wallentin, L. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067722 · Cited by 1,197
The Pathology of Neoatherosclerosis in Human Coronary Implants
Nakazawa, G., Otsuka, F., Nakano, M., Vorpahl, M., Yazdani, S. K., Ladich, E., Kolodgie, F. D., Finn, A. V., & Virmani, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.011 · Cited by 934
Erbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Self-citationEverolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
Orchard, T. J. (1974) · The Lancet · doi:10.1016/s0140-6736(74)92567-7 · Cited by 853
Serruys, P. W., Ormiston, J. A., Onuma, Y., Regar, E., Gonzalo, N., Garcia-Garcia, H. M., Nieman, K., Bruining, N., Dorange, C., Miquel-Hébert, K., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60325-1 · Cited by 820
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery Stent
Serruys, P. W., Strauss, B. H., Beatt, K. J., Bertrand, M. E., Puel, J., Rickards, A. F., Meier, B., Goy, J.-J., Vogt, P., Kappenberger, L., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240103 · Cited by 732
Self-citationBiodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, M., & Mantovani, D. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12074250 · Cited by 600
Roubin, G. S., Cannon, A. D., Agrawal, S. K., Macander, P. J., Dean, L. S., Baxley, W. A., & Breland, J. (1992) · Circulation · doi:10.1161/01.cir.85.3.916 · Cited by 582
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Self-citationHaude, M., Erbel, R., Erne, P., Verheye, S., Degen, H., Böse, D., Vermeersch, P., Wijnbergen, I., Weissman, N., Prati, F., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61765-6 · Cited by 423
Self-citationStefanini, G. G., Kalesan, B., Serruys, P. W., Heg, D., Buszman, P., Linke, A., Ischinger, T., Klauss, V., Eberli, F., Wijns, W., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61672-3 · Cited by 354
Self-citationSafety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330
Self-citationOnuma, Y., Serruys, P. W., Perkins, L. E. L., Okamura, T., Gonzalo, N., García-García, H. M., Regar, E., Kamberi, M., Powers, J. C., Rapoza, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.921528 · Cited by 319
Self-citationCoronary stents: historical development, current status and future directions
Iqbal, J., Gunn, J., & Serruys, P. W. (2013) · British Medical Bulletin · doi:10.1093/bmb/ldt009 · Cited by 319
Self-citationSerruys, P. W., Garcia-Garcia, H. M., & Onuma, Y. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr384 · Cited by 303
Self-citationJournal of Invasive Cardiology
(2023) · The Journal of invasive cardiology/The journal of invasive cardiology · doi:10.25270/jic · Cited by 285
Short‐Term Effects of Biocorrodible Iron Stents in Porcine Coronary Arteries
WAKSMAN, R., PAKALA, R., BAFFOUR, R., SEABRON, R., HELLINGA, D., & TIO, F. O. (2008) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.2007.00319.x · Cited by 244
Self-citationNishio, S., Kosuga, K., Igaki, K., Okada, M., Kyo, E., Tsuji, T., Takeuchi, E., Inuzuka, Y., Takeda, S., Hata, T., et al. (2012) · Circulation · doi:10.1161/circulationaha.110.000901 · Cited by 240
Self-citationSerruys, P. W., Onuma, Y., Garcia-Garcia, H. M., Muramatsu, T., van Geuns, R.-J., de Bruyne, B., Dudek, D., Thuesen, L., Smits, P. C., Chevalier, B., et al. (2014) · EuroIntervention · doi:10.4244/eijv9i11a217 · Cited by 239
Self-citationOrmiston, J. A., Serruys, P. W., Onuma, Y., van Geuns, R.-J., de Bruyne, B., Dudek, D., Thuesen, L., Smits, P. C., Chevalier, B., McClean, D., et al. (2012) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.112.971549 · Cited by 201
Self-citationTanimoto, S., Serruys, P. W. J. C., Thuesen, L., Dudek, D., Bruyne, B. D., Chevalier, B., & Ormiston, J. A. (2007) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21136 · Cited by 151
Self-citationBrugaletta, S., Heo, J. H., García‐García, H. M., Farooq, V., van Geuns, R., Bruyne, B. D., Dudek, D., Smits, P. C., Koolen, J., McClean, D., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr466 · Cited by 143
Self-citationBiodegradable stents: they do their job and disappear.
Waksman, R. (2006) · PubMed · Cited by 141
Self-citationDudek, D., Onuma, Y., Ormiston, J., Thuesen, L., Miquel‐Hébert, K., & Serruys, P. W. J. C. (2012) · EuroIntervention · doi:10.4244/eijv7i9a168 · Cited by 136
Self-citationABSORB II randomized controlled trial
Diletti, R., Serruys, P. W. J. C., Farooq, V., Sudhir, K., Dorange, C., Miquel‐Hébert, K., Veldhof, S., Rapoza, R. R., Onuma, Y., García‐García, H. M., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.08.010 · Cited by 133
Self-citationBrugaletta, S., Radu, M., García‐García, H. M., Heo, J. H., Farooq, V., Girasis, C., van Geuns, R., Thuesen, L., McClean, D., Chevalier, B., et al. (2011) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2011.12.008 · Cited by 129
Self-citationGyöngyösi, M., Yang, P., Khorsand, A., & Glogar, D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00570-2 · Cited by 128
Muramatsu, T., Onuma, Y., García‐García, H. M., Farooq, V., Bourantas, C. V., Morel, M.-A., Li, X., Veldhof, S., Bartorelli, A. L., Whitbourn, R., et al. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.10.013 · Cited by 115
Self-citationOnuma, Y., Serruys, P. W. J. C., Gomez, J., Bruyne, B. D., Dudek, D., Thuesen, L., Smits, P., Chevalier, B., McClean, D., Koolen, J., et al. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22864 · Cited by 110
Self-citationLu, P., Cao, L., Liu, Y., Xu, X., & Wu, X. (2011) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31744 · Cited by 108
Lara, J. G., García‐García, H. M., Onuma, Y., Garg, S., Regar, E. S., Bruyne, B. D., Windecker, S., McClean, D., Thuesen, L., Dudek, D., et al. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.07.016 · Cited by 106
Self-citationIqbal, J., Sumaya, W., Tatman, V., Parviz, Y., Morton, A. C., Grech, E. D., Campbell, S., Storey, R. F., & Gunn, J. P. (2013) · EuroIntervention · doi:10.4244/eijv9i1a10 · Cited by 92
Self-citationBioresorbable Polymeric Vascular Scaffolds: A Cautionary Tale
Ormiston, J. A., Vroey, F. D., Serruys, P. W. J. C., & Webster, M. W. I. (2011) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.963710 · Cited by 81
Self-citationDiletti, R., Farooq, V., Girasis, C., Bourantas, C. V., Onuma, Y., Heo, J. H., Gogas, B. D., van Geuns, R., Regar, E., Bruyne, B. D., et al. (2012) · Heart · doi:10.1136/heartjnl-2012-302598 · Cited by 81
Self-citationGhimire, G., Spiro, J. R., Kharbanda, R. K., Roughton, M., Barlis, P., Mason, M. J., Ilsley, C. D. J., Mario, C. D., Erbel, R. M., Waksman, R., et al. (2009) · EuroIntervention · doi:10.4244/jv4i4a82 · Cited by 70
Self-citationBrugaletta, S., Gogas, B. D., García‐García, H. M., Farooq, V., Girasis, C., Heo, J. H., van Geuns, R., Bruyne, B. D., Dudek, D., Koolen, J., et al. (2012) · Circulation Journal · doi:10.1253/circj.cj-11-1416 · Cited by 66
Self-citationNovel bioabsorbable salicylate‐based polymer as a drug‐eluting stent coating
Jabara, R., Chronos, N. A. F., & Robinson, K. A. (2008) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21607 · Cited by 63
Novel fully bioabsorbable salicylate-based sirolimus-eluting stent
Jabara, R., PENDYALA, L. K., Geva, S., Chen, J., Chronos, N. A. F., & Robinson, K. A. (2009) · EuroIntervention · doi:10.4244/eijv5ifa10 · Cited by 58
Lara, J. G., Brugaletta, S., Farooq, V., van Geuns, R., Bruyne, B. D., Windecker, S., McClean, D., Thuesen, L., Dudek, D., Koolen, J., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.04.009 · Cited by 57
Self-citationBruining, N., Tanimoto, S., Otsuka, M., Weustink, A. C., Ligthart, J. M. R., de Winter, S., van Mieghem, C. A. G., Nieman, K., de Feyter, P. J., van Domburg, R., et al. (2008) · EuroIntervention · doi:10.4244/eijv4i2a49 · Cited by 46
Self-citationOptimal revascularization for complex coronary artery disease
Iqbal, J., Serruys, P. W. J. C., & Taggart, D. P. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.138 · Cited by 46
Self-citationWu, Y., Shen, L., Wang, Q., Ge, L., Xie, J., Hu, X., Sun, A., Qian, J., & Ge, J. (2012) · BioMed Research International · doi:10.1155/2012/413956 · Cited by 34
Onuma, Y., Garg, S., Okamura, T., Ligthart, J. M. R., van Geuns, R., de Feyter, P. J., Serruys, P. W. J. C., & Tamai, H. (2009) · EuroIntervention · doi:10.4244/eijv5ifa19 · Cited by 29
Self-citationAdjusting a polymer formulation for an optimal bioresorbable stent: a 6-month follow-up study
Durand, É., Lemitre, M., Couty, L., Sharkawi, T., Brasselet, C., Vert, M., & Lafont, A. M. (2012) · EuroIntervention · doi:10.4244/eijv8i2a38 · Cited by 18
First experience of a bioresorbable vascular scaffold implantation in left main stenosis
Fernández-Rodríguez, D., Brugaletta, S., Martín‐Yuste, V., Regueiro, A., Mingo, A. D., Santos, A. N., Masotti, M., & Sabaté, M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.061 · Cited by 14
Cited by
Toughening of photo-curable polymer networks: a review
Ligon-Auer, S. C., Schwentenwein, M., Gorsche, C., Stampfl, J., & Liska, R. (2016) · Polymer Chemistry · doi:10.1039/c5py01631b · Cited by 447
Cassese, S., Byrne, R. A., Ndrepepa, G., Kufner, S., Wiebe, J., Repp, J., Schunkert, H., Fusaro, M., Kimura, T., & Kastrati, A. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00979-4 · Cited by 369
Haude, M., Ince, H., Abizaid, A., Toelg, R., Lemos, P. A., von Birgelen, C., Christiansen, E. H., Wijns, W., Neumann, F.-J., Kaiser, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00447-x · Cited by 349
Self-citationFully bioresorbable vascular scaffolds: lessons learned and future directions
Jinnouchi, H., Torii, S., Sakamoto, A., Kolodgie, F. D., Virmani, R., & Finn, A. V. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0124-7 · Cited by 228
Cardiovascular stents: overview, evolution, and next generation
Borhani, S., Hassanajili, S., Ahmadi Tafti, S. H., & Rabbani, S. (2018) · Progress in Biomaterials · doi:10.1007/s40204-018-0097-y · Cited by 226
Metadata
- Authors
- Iqbal, J., Onuma, Y., Ormiston, J., Abizaid, A., Waksman, R., & Serruys, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-12-23
- Volume
- 35
- Issue
- 12
- Pages
- 765-776
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2165754633
- Cited by
- 269
- References
- 56
- FWCI
- 29.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.