Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
AIMS: Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. METHODS AND RESULTS: Patients having Class I or II indication for VVI pacing underwent implantation of a Micra transcatheter pacing system, from the femoral vein and fixated in the right ventricle using four protractible nitinol tines. Prespecified objectives were >85% freedom from unanticipated serious adverse device events (safety) and <2 V 3-month mean pacing capture threshold at 0.24 ms pulse width (efficacy). Patients were implanted (n = 140) from 23 centres in 11 countries (61% male, age 77.0 ± 10.2 years) for atrioventricular block (66%) or sinus node dysfunction (29%) indications. During mean follow-up of 1.9 ± 1.8 months, the safety endpoint was met with no unanticipated serious adverse device events. Thirty adverse events related to the system or procedure occurred, mostly due to transient dysrhythmias or femoral access complications. One pericardial effusion without tamponade occurred after 18 device deployments. In 60 patients followed to 3 months, mean pacing threshold was 0.51 ± 0.22 V, and no threshold was ≥2 V, meeting the efficacy endpoint (P < 0.001). Average R-wave was 16.1 ± 5.2 mV and impedance was 650.7 ± 130 ohms. CONCLUSION: Early assessment shows the transcatheter pacemaker can safely and effectively be applied. Long-term safety and benefit of the pacemaker will further be evaluated in the trial. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov ID NCT02004873.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2023 Update: A Report From the American Heart Association
Tsao, C. W., Aday, A. W., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Beaton, A. Z., Boehme, A. K., Buxton, A. E., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001123 · Cited by 8,300
Heart Disease and Stroke Statistics—2011 Update: A Report From the American Heart Association
Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Adams, R. J., Berry, J. D., Brown, T. M., Carnethon, M. R., Dai, S., de Simone, G., Ford, E. S., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3182009701 · Cited by 6,149
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Kirkfeldt, R. E., Johansen, J. B., Nohr, E. A., Jorgensen, O. D., & Nielsen, J. C. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht511 · Cited by 871 · cited 1×
“These are reported to be 20% at 5 years, with highest contributions related to the pacing lead ( 11%) and pocket ( 8%),(4) including pneumo/ haemothorax after subclavian vein puncture, pocket haematoma, erosion or infection, vein stenosis or occlusion, endocarditis, tricuspid valve trauma, connection troubles, lead fr…”
BackgroundPoole, J. E., Gleva, M. J., Mela, T., Chung, M. K., Uslan, D. Z., Borge, R., Gottipaty, V., Shinn, T., Dan, D., Feldman, L. A., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.976076 · Cited by 790
Greenspon, A. J., Patel, J. D., Lau, E., Ochoa, J. A., Frisch, D. R., Ho, R. T., Pavri, B. B., & Kurtz, S. M. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.04.033 · Cited by 780
Tracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597 · cited 2×
“Today, it is estimated that 600 000 pacemakers are implanted worldwide each year,17 358 000 of which are in the USA.18 Compared with single-chamber atrial-based systems and the more costly dual-chamber systems, VVI pacemaker utilization varies regionally with rates reported from trials of 8% in the USA19 and 25% in th…”
BackgroundJohansen, J. B., Jorgensen, O. D., Moller, M., Arnsbo, P., Mortensen, P. T., & Nielsen, J. C. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq497 · Cited by 376
Permanent Leadless Cardiac Pacing: Results of the LEADLESS Trial
Reddy, V. Y., Knops, R. E., Sperzel, J., Miller, M. A., Petru, J., Simon, J., Sediva, L., de Groot, J. R., Tjong, F. V. Y., Jacobson, P., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006987 · Cited by 308 · cited 1×
“In the LEADLESS Trial, the Nanostim leadless cardiac pacemaker (St Jude Medical, St Paul, MN, USA) was successfully implanted in 32 of 33 patients.(16) One patient experienced a RV perforation and cardiac tamponade during the procedure, and later died as a result of stroke.”
MethodSelf-citationTrends in cardiac pacemaker batteries.
Mallela, V. S., Ilankumaran, V., & Rao, N. S. (2004) · PubMed · Cited by 253
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202 · cited 1×
“Atrial and dual-chamber pacing modes have recently been preferred for bradyarrhythmia patients without permanent or persistent atrial tachyarrhythmia due to risks associated with AV dysynchrony, notably pacemaker syndrome.(19) Over one-third of the patients who received TPS in our trial were without history of permane…”
BackgroundHauser, R. G., Hayes, D. L., Kallinen, L. M., Cannom, D. S., Epstein, A. E., Almquist, A. K., Song, S. L., Tyers, G. F. O., Vlay, S. C., & Irwin, M. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.10.009 · Cited by 165
Survival in second degree atrioventricular block
Shaw, D. B., Kekwick, C. A., Veale, D., Gowers, J., & Whistance, T. (1985) · Heart · doi:10.1136/hrt.53.6.587 · Cited by 132
Ritter, P., Duray, G. Z., Zhang, S., Narasimhan, C., Soejima, K., Omar, R., Laager, V., Stromberg, K. D., Williams, E., Reynolds, D., et al. (2015) · EP Europace · doi:10.1093/europace/euv026 · Cited by 108
Self-citationHRS/ACCF Expert Consensus Statement on Pacemaker Device and Mode Selection
Gillis, A. M., Russo, A. M., Ellenbogen, K. A., Swerdlow, C. D., Olshansky, B., Al‐Khatib, S. M., Beshai, J. F., McComb, J. M., Nielsen, J. C., Philpott, J. M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.06.011 · Cited by 104 · cited 1×
“VVI pacemakers are guideline recommended for patients with permanent or persistent atrial arrhythmias and slow intrinsic heart rates.(20) Future developments of this technology may include AAI, VDD, DDD, or even biventricular pacing systems.”
BackgroundPacemaker Longevity: Are We Getting What We Are Promised?
Senaratne, J. M., IRWIN, M. E., & SENARATNE, M. P. J. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00497.x · Cited by 27
Atrial Fibrillation Therapy in Patients with a CRT Defibrillator with Wireless Telemetry
Crossley, G. H., Aonuma, K., HAFFAJEE, C., Shoda, M., Meijer, A., Bauer, A., Boriani, G., Svendsen, J. H., THOMAS, S., Wiggenhorn, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02171.x · Cited by 13
Cited by
A Leadless Intracardiac Transcatheter Pacing System
Reynolds, D., Duray, G. Z., Omar, R., Soejima, K., Neuzil, P., Zhang, S., Narasimhan, C., Steinwender, C., Brugada, J., Lloyd, M., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1511643 · Cited by 933
Self-citationOuyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 647
Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Duray, G. Z., Ritter, P., El-Chami, M., Narasimhan, C., Omar, R., Tolosana, J. M., Zhang, S., Soejima, K., Steinwender, C., Rapallini, L., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.01.035 · Cited by 302
Self-citationEmerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Metadata
- Authors
- Ritter, P., Duray, G. Z., Steinwender, C., Soejima, K., Omar, R., Mont, L., Boersma, L. V., Knops, R. E., Chinitz, L., Zhang, S., Narasimhan, C., Hummel, J., Lloyd, M., Simmers, T. A., Voigt, A., Laager, V., Stromberg, K., Bonner, M. D., Sheldon, T. J., & Reynolds, D.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-06-04
- Volume
- 36
- Issue
- 37
- Pages
- 2510-2519
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W1935256408
- Cited by
- 229
- References
- 19
- FWCI
- 20.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.