Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Aims: The incidence of new-onset conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with new-generation prostheses remains debated. This systematic review analyses the incidence of PPI after TAVI with new-generation devices and evaluates the electrical, anatomical, and procedural factors associated with PPI. In addition, the incidence of PPI after TAVI with early generation prostheses was reviewed for comparison. Methods and results: According to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist, this systematic review screened original articles published between October 2010 and October 2017, reporting on the incidence of PPI after implantation of early and new-generation TAVI prostheses. Of the 1406 original articles identified in the first search for new-generation TAVI devices, 348 articles were examined for full text, and finally, 40 studies (n = 17 139) were included. The incidence of a PPI after the use of a new-generation TAVI prosthesis ranged between 2.3% and 36.1%. For balloon-expandable prostheses, the PPI rate remained low when using an early generation SAPIEN device (ranging between 2.3% and 28.2%), and with the new-generation SAPIEN 3 device, the PPI rate was between 4.0% and 24.0%. For self-expandable prostheses, the PPI rates were higher with the early generation CoreValve device (16.3-37.7%), and despite a reduction in PPI rates with the new Evolut R, the rates remained relatively higher (14.7-26.7%). When dividing the studies according to the highest (>26.0%) and the lowest (<12.1%) quintile of PPI rate, patients within the highest quintile were more frequently women when compared with the lowest quintile group (50.9% vs. 46.3%, P < 0.001). Pre-existent conduction abnormalities (electrical factor), calcification of the left ventricular outflow tract (anatomical factor), and balloon valvuloplasty and depth of implantation (procedural factors) were associated with increased risk of PPI. Conclusion: The rate of PPI after TAVI with new-generation devices is highly variable. Specific recommendations for implantation of each prosthesis, taking into consideration the presence of pre-existent conduction abnormalities and anatomical factors, may be needed to reduce the risk of PPI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.011 · Cited by 3,339
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients
Reardon, M. J., Van Mieghem, N. M., Popma, J. J., Kleiman, N. S., Søndergaard, L., Mumtaz, M., Adams, D. H., Deeb, G. M., Maini, B., Gada, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700456 · Cited by 3,009
Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Popma, J. J., Adams, D. H., Reardon, M. J., Yakubov, S. J., Kleiman, N. S., Heimansohn, D., Hermiller, J., Hughes, G. C., Harrison, J. K., Coselli, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.556 · Cited by 1,040
Rodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., et al. (2014) · JAMA · doi:10.1001/jama.2014.3316 · Cited by 686
Siontis, G. C. M., Jüni, P., Pilgrim, T., Stortecky, S., Büllesfeld, L., Meier, B., Wenaweser, P., & Windecker, S. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.033 · Cited by 647
Nazif, T. M., Dizon, J. M., Hahn, R. T., Xu, K., Babaliaros, V., Douglas, P. S., El-Chami, M. F., Herrmann, H. C., Mack, M., Makkar, R. R., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.07.022 · Cited by 532
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2013) · Survey of Anesthesiology · doi:10.1097/01.sa.0000426523.25196.4e · Cited by 454
One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
Lefevre, T., Kappetein, A. P., Wolner, E., Nataf, P., Thomas, M., Schachinger, V., De Bruyne, B., Eltchaninoff, H., Thielmann, M., Himbert, D., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq427 · Cited by 376
Kodali, S., Thourani, V. H., White, J., Malaisrie, S. C., Lim, S., Greason, K. L., Williams, M., Guerrero, M., Eisenhauer, A. C., Kapadia, S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw112 · Cited by 352
Fadahunsi, O. O., Olowoyeye, A., Ukaigwe, A., Li, Z., Vora, A. N., Vemulapalli, S., Elgin, E., & Donato, A. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.026 · Cited by 335
Khawaja, M. Z., Rajani, R., Cook, A., Khavandi, A., Moynagh, A., Chowdhary, S., Spence, M. S., Brown, S., Khan, S. Q., Walker, N., et al. (2011) · Circulation · doi:10.1161/circulationaha.109.927152 · Cited by 313
Multicenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve
Webb, J., Gerosa, G., Lefèvre, T., Leipsic, J., Spence, M., Thomas, M., Thielmann, M., Treede, H., Wendler, O., & Walther, T. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.026 · Cited by 313
Urena, M., Webb, J. G., Tamburino, C., Muñoz-García, A. J., Cheema, A., Dager, A. E., Serra, V., Amat-Santos, I. J., Barbanti, M., Immè, S., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005479 · Cited by 304
Petronio, A. S., De Carlo, M., Bedogni, F., Marzocchi, A., Klugmann, S., Maisano, F., Ramondo, A., Ussia, G. P., Ettori, F., Poli, A., et al. (2010) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.109.930453 · Cited by 290
Regueiro, A., Abdul-Jawad Altisent, O., Del Trigo, M., Campelo-Parada, F., Puri, R., Urena, M., Philippon, F., & Rodés-Cabau, J. (2016) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.115.003635 · Cited by 287
A Highly Predictive Risk Model for Pacemaker Implantation After TAVR
Maeno, Y., Abramowitz, Y., Kawamori, H., Kazuno, Y., Kubo, S., Takahashi, N., Mangat, G., Okuyama, K., Kashif, M., Chakravarty, T., et al. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.11.020 · Cited by 251
Predictors for New-Onset Complete Heart Block After Transcatheter Aortic Valve Implantation
Bleiziffer, S., Ruge, H., Hörer, J., Hutter, A., Geisbüsch, S., Brockmann, G., Mazzitelli, D., Bauernschmitt, R., & Lange, R. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.01.017 · Cited by 226
Bosmans, J. M., Kefer, J., De Bruyne, B., Herijgers, P., Dubois, C., Legrand, V., Verheye, S., Rodrigus, I., & for the Belgian TAVI Registry Participants (2011) · Interactive CardioVascular and Thoracic Surgery · doi:10.1510/icvts.2010.253773 · Cited by 220
Mauri, V., Reimann, A., Stern, D., Scherner, M., Kuhn, E., Rudolph, V., Rosenkranz, S., Eghbalzadeh, K., Friedrichs, K., Wahlers, T., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.08.034 · Cited by 219
Linke, A., Wenaweser, P., Gerckens, U., Tamburino, C., Bosmans, J., Bleiziffer, S., Blackman, D., Schafer, U., Muller, R., Sievert, H., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu162 · Cited by 206
Wendler, O., Schymik, G., Treede, H., Baumgartner, H., Dumonteil, N., Ihlberg, L., Neumann, F.-J., Tarantini, G., Zamarano, J. L., & Vahanian, A. (2017) · Circulation · doi:10.1161/circulationaha.116.025103 · Cited by 194
Popma, J. J., Reardon, M. J., Khabbaz, K., Harrison, J. K., Hughes, G. C., Kodali, S., George, I., Deeb, G. M., Chetcuti, S., Kipperman, R., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.08.050 · Cited by 180
Husser, O., Pellegrini, C., Kessler, T., Burgdorf, C., Thaller, H., Mayr, N. P., Kasel, A. M., Kastrati, A., Schunkert, H., & Hengstenberg, C. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.09.036 · Cited by 177
Bagur, R., Rodés-Cabau, J., Gurvitch, R., Dumont, É., Velianou, J. L., Manazzoni, J., Toggweiler, S., Cheung, A., Ye, J., Natarajan, M. K., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.03.004 · Cited by 171
De Torres-Alba, F., Kaleschke, G., Diller, G. P., Vormbrock, J., Orwat, S., Radke, R., Reinke, F., Fischer, D., Reinecke, H., & Baumgartner, H. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.12.023 · Cited by 166
Visualizing anatomical evidences on atrioventricular conduction system for TAVI
Kawashima, T., & Sato, F. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.04.003 · Cited by 161
Toggweiler, S., Stortecky, S., Holy, E. W., Zuk, K., Cuculi, F., Nietlispach, F., Sabti, Z., Suciu, R., Maier, W., Jamshidi, P., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.03.024 · Cited by 160
Petronio, A. S., Sinning, J., Mieghem, N. M. V., Zucchelli, G., Nickenig, G., Bekeredjian, R., Bosmans, J. M., Bedogni, F., Branny, M., Stangl, K., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.02.005 · Cited by 155
Ewe, S. H., Marsan, N. A., Pepi, M., Delgado, V., Tamborini, G., Muratori, M., Ng, A. C. T., van der Kley, F., de Weger, A., Schalij, M. J., et al. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.09.003 · Cited by 153
Self-citationClinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis
Grube, E., Mieghem, N. M. V., Bleiziffer, S., Modine, T., Bosmans, J. M., Manoharan, G., Linke, A. H.-P., Scholtz, W., Tchétché, D., Finkelstein, A., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.06.045 · Cited by 153
Auffret, V., Webb, J. G., Eltchaninoff, H., Muñoz-García, A. J., Himbert, D., Tamburino, C., y, L. N.-F., Nietlispach, F., Morís, C., Ruel, M., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.05.030 · Cited by 134
Schymik, G., Tzamalis, P., Bramlage, P., Heimeshoff, M., Würth, A., Wondraschek, R., Gonska, B., Posival, H., Schmitt, C., Schröfel, H., et al. (2014) · Clinical Research in Cardiology · doi:10.1007/s00392-014-0791-2 · Cited by 124
Carlo, M. D., Giannini, C., Bedogni, F., Klugmann, S., Brambilla, N., MARCO, F. D., Zucchelli, G., Testa, L., Oreglia, J., & Petronio, A. S. (2012) · American Heart Journal · doi:10.1016/j.ahj.2011.12.009 · Cited by 122
van der Boon, R. M. A., Mieghem, N. M. V., Theuns, D. A. M. J., Nuis, R.-J. M., Nauta, S. T., Serruys, P. W. J. C., Jordaens, L. J. L. M., van Domburg, R. T., & de Jaegere, P. P. T. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.11.115 · Cited by 118
Rubín, J. M., y, P. A., del Valle-Fernández, R., Renilla, A., Ríos, E., Calvo, D., Lozano, Í., Anguera, I., Molina, B. D., Cequier, A. R., et al. (2011) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.111.961649 · Cited by 102
Ledwoch, J., Franke, J., Gerckens, U. J., Kück, K., Linke, A. H.-P., Nickenig, G., Krülls-Münch, J., Vöhringer, M. C., Hambrecht, R., Erbel, R. M., et al. (2013) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24915 · Cited by 92
Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve
Kalra, S. S., Firoozi, S., Yeh, J. S. M., Blackman, D. J., Rashid, S., Davies, S., Moat, N. E., Dalby, M. C. D., Kabir, T., Khogali, S., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.11.025 · Cited by 88
Outcomes After Transcatheter Aortic Valve Implantation: Transfemoral Versus Transapical Approach
Ewe, S. H., Delgado, V., Ng, A. C. T., Antoni, M. L., van der Kley, F., Marsan, N. A., de Weger, A., Tavilla, G., Holman, E. R., Schalij, M. J., et al. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.01.059 · Cited by 79
Self-citationFalk, V., Wöhrle, J., Hildick‐Smith, D., Bleiziffer, S., Blackman, D. J., Abdel‐Wahab, M., Gerckens, U. J., Linke, A. H.-P., İnce, H., Wenaweser, P., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx297 · Cited by 74
Very low pacemaker rate following ACURATE neo transcatheter heart valve implantation
Toggweiler, S., Nissen, H., Mogensen, B., Cuculi, F., Fallesen, C. O., Veien, K. T., Brinkert, M., Kobza, R., & Rück, A. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00252 · Cited by 73
Muñoz-García, A. J., Hernández-García, J. M., Jiménez-Navarro, M. F., Alonso-Briales, J. H., Domínguez-Franco, A. J., Fernández-Pastor, J., Peña-Hernández, J., Cordero, A. B., Rodríguez, J. A., & de Teresa–Galván, E. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.03.011 · Cited by 71
Mohananey, D., Jobanputra, Y. B., Kumar, A., Krishnaswamy, A., Mick, S., White, J., & Kapadia, S. R. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005046 · Cited by 71
Calvi, V. I., Conti, S., Pruiti, G. P., Capodanno, D., Puzzangara, E., Tempio, D., Grazia, A. D., Ussia, G. P., & Tamburino, C. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9634-5 · Cited by 66
Ben‐Shoshan, J., Konigstein, M., Zahler, D., Margolis, G., Chorin, E., Steinvil, A., Arbel, Y., Aviram, G., Granot, Y. N., Barkagan, M., et al. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.09.030 · Cited by 65
Maan, A., Refaat, M. M., Heist, E. K., Passeri, J. J., Inglessis, I., Ptaszek, L. M., Vlahakes, G. J., Ruskin, J. N., Palacios, I. F., Sundt, T. M., et al. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12653 · Cited by 63
Sorajja, P., Kodali, S., Reardon, M. J., Szeto, W. Y., Chetcuti, S. J., Hermiller, J. B., Chenoweth, S., Adams, D. H., & Popma, J. J. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.07.027 · Cited by 63
Möllmann, H., Linke, A. H.-P., Holzhey, D. M., Walther, T., Manoharan, G., Schäfer, U., Kück, K., Boven, A. J. V., Redwood, S. R., Kováč, J., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.05.021 · Cited by 61
Noble, S., Stortecky, S., Heg, D., Tueller, D., Jeger, R. V., Toggweiler, S., Ferrari, E., Nietlispach, F., Taramasso, M., Maisano, F., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00677 · Cited by 60
Gonska, B., Seeger, J., Keßler, M., von Keil, A., Rottbauer, W., & Wöhrle, J. (2017) · Clinical Research in Cardiology · doi:10.1007/s00392-017-1093-2 · Cited by 59
Gomes, B., Geis, N. A., Chorianopoulos, E., Meder, B., Leuschner, F., Katus, H. A., & Bekeredjian, R. (2016) · Journal of Interventional Cardiology · doi:10.1111/joic.12356 · Cited by 57
Hüsser, O., Pellegrini, C., Kessler, T., Burgdorf, C., Thaller, H., Mayr, N. P., Ott, I., Kasel, A. M., Schunkert, H., Kastrati, A., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.08.014 · Cited by 55
Tovia‐Brodie, O., Ben‐Haim, Y., Joffe, E., Finkelstein, A., Glick, A., Rosso, R., Belhassen, B., & Michowitz, Y. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0218-2 · Cited by 53
NAVEH, S., Perlman, G., ELITSUR, Y., Planer, D., Gilon, D., Leibowitz, D. W., Lotan, C., Danenberg, H. D., & Alcalai, R. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13147 · Cited by 50
Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Valve
Rampat, R., Khawaja, M. Z., Byrne, J., MacCarthy, P. A., Blackman, D. J., Krishnamurthy, A., Gunarathne, A., Kovac, J., BANNING, A. P., Kharbanda, R. K., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.12.012 · Cited by 48
Vahanian, A. S., Ureña, M., Walther, T., Treede, H., Wendler, O., Lefèvre, T., Spence, M. S., Redwood, S. R., Kahlert, P., Rodés‐Cabau, J., et al. (2016) · EuroIntervention · doi:10.4244/eijv12i2a37 · Cited by 48
Prospective Multicenter Evaluation of the Direct Flow Medical Transcatheter Aortic Valve System
Lefèvre, T., Colombo, A., Tchétché, D., Latib, A., Klugmann, S., Fajadet, J. C., MARCO, F. D., Maisano, F., Bruschi, G., Bijuklic, K., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.09.027 · Cited by 43
Jochheim, D., Zadrozny, M., Theiss, H. D., Baquet, M., Maimer-Rodrigues, F., Bauer, A., Lange, P., Greif, M., Kupatt, C., Hausleiter, J., et al. (2015) · EuroIntervention · doi:10.4244/eijv11i2a40 · Cited by 37
Silaschi, M., Treede, H., Rastan, A. J., Baumbach, H., Beyersdorf, F., Kappert, U., Eichinger, W. B., Rüter, F., de Kroon, T. L., Lange, R., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw170 · Cited by 37
Backer, O. D., Götberg, M., Ihlberg, L. H. M., Packer, E. J. S., Savontaus, M., Nielsen, N. E., Jørgensen, T., Nykänen, A. I., Baranowski, J., Niemelä, M. J., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.05.072 · Cited by 37
Pilgrim, T., Stortecky, S., Nietlispach, F., Heg, D., Tueller, D., Toggweiler, S., Ferrari, E., Noble, S., Maisano, F., Jeger, R. V., et al. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.004088 · Cited by 37
Sawaya, F., Spaziano, M., Lefèvre, T., Roy, A. K., Garot, P., Hovasse, T., Neylon, A. M., Benamer, H., Romano, M., Unterseeh, T., et al. (2016) · World Journal of Cardiology · doi:10.4330/wjc.v8.i12.735 · Cited by 36
Dumonteil, N., Meredith, I. T., Blackman, D. J., Tchétché, D., Hildick‐Smith, D., Spence, M., Walters, D., Harnek, J., Worthley, S. G., Rioufol, G., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-01025 · Cited by 31
Badenco, N., Chong-Nguyen, C., Maupain, C., Himbert, C., Duthoit, G., Waintraub, X., Chastre, T., Gandjbakhch, E., Hidden‐Lucet, F., Leprince, P. N., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.029 · Cited by 28
Hamm, K., Reents, W., Zacher, M., Kerber, S., Diegeler, A., Schieffer, B., & Barth, S. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00898 · Cited by 26
Seeger, J., Gonska, B., Rottbauer, W., & Wöhrle, J. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.004670 · Cited by 23
Börgermann, J., Holzhey, D. M., Thielmann, M., Girdauskas, E., Schroefel, H., Hofmann, S., Treede, H., Matschke, K. E., Hilker, M., Strauch, J. T., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw423 · Cited by 19
Montone, R. A., Testa, L., Fraccaro, C., Montorfano, M., Castriota, F., Nerla, R., Angelillis, M., Tusa, M. B., Giannini, F., Garatti, A., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26914 · Cited by 16
Naber, C. K., Pyxaras, S. A., İnce, H., Frambach, P., Colombo, A., Butter, C., Gatto, F., Hink, U., Nickenig, G., Bruschi, G., et al. (2016) · EuroIntervention · doi:10.4244/eij-d-15-00511 · Cited by 12
Giannini, F., Latib, A., Montorfano, M., Ruparelia, N., Romano, V., Longoni, M., Ferri, L., Jabbour, R. J., Mangieri, A., Regazzoli, D., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27319 · Cited by 4
Cited by
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationVARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citationManagement of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement
Rodés-Cabau, J., Ellenbogen, K. A., Krahn, A. D., Latib, A., Mack, M., Mittal, S., Muntané-Carol, G., Nazif, T. M., Sondergaard, L., Urena, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.07.014 · Cited by 344
Thiele, H., Kurz, T., Feistritzer, H.-J., Stachel, G., Hartung, P., Eitel, I., Marquetand, C., Nef, H., Doerr, O., Lauten, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa036 · Cited by 262
Sammour, Y., Krishnaswamy, A., Kumar, A., Puri, R., Tarakji, K. G., Bazarbashi, N., Harb, S., Griffin, B., Svensson, L., Wazni, O., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.09.063 · Cited by 255
Metadata
- Authors
- van Rosendael, P. J., Delgado, V., & Bax, J. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2018-02-06
- Volume
- 39
- Issue
- 21
- Pages
- 2003-2013
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2790332731
- Cited by
- 292
- References
- 76
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.