CoChat

Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations

Open access
Locati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., Lunati, M. · 2014 · Europace
Cited by 53

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

AIMS: To assess the diagnostic yield of new external loop recorders (ELRs) in patients with history of syncope, pre-syncope, and sustained palpitations. METHODS AND RESULTS: Since 2005, we have established a registry including patients who consecutively received ELR monitoring for unexplained syncope or pre-syncope/palpitations. The registry included 307 patients (61% females, age 58 ± 19 years, range 8-94 years) monitored by high-capacity memory ELR of two subsequent generations: SpiderFlash-A(®) (SFA(®), Sorin CRM), storing two-lead electrocardiogram (ECG) patient-activated recordings by loop-recording technique (191 patients, 54 patients with syncope, years 2005-09), and SpiderFlash-T(®) (SFT(®)), adding auto-trigger detection for pauses, bradycardia, and supraventricular/ventricular arrhythmias (116 patients, 38 patients with syncope, years 2009-12). All the patients previously underwent routine workup for syncope or palpitation, including one or more 24 h Holter, not conclusive for diagnosis. Mean monitoring duration was 24.1 ± 8.9 days. Among 215 patients with palpitations, a conclusive diagnosis was obtained in 184 patients (86% diagnostic yield for palpitation). Among 92 patients with syncope, a conclusive diagnosis was obtained in 16 patients (17% clinical diagnostic yield for syncope), with recording during syncope of significant arrhythmias in 9 patients, and sinus rhythm in 7 patients. Furthermore, asymptomatic arrhythmias were de novo detected in 12 patients (13%), mainly by auto-trigger detection, suggesting an arrhythmic origin of the syncope. CONCLUSIONS: The diagnostic yield of ELR in patients with syncope, pre-syncope, or palpitation of unknown origin after routine workup was similar to implantable loop recorder (ILR) within the same timeframe, therefore, ELR could be considered for patients candidate for long-term ECG monitoring, stepwise before ILR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eut337

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 16

  1. 2006, Europace, 8, 746, 10.1093/europace/eul108 · DOI · Paper page
  2. 2003, Circulation, 108, 871
  3. 2010, Europace, 12, 1360, 10.1093/europace/euq350 · DOI · Paper page
  4. 2013, Europace, 15, 122, 10.1093/europace/eus264 · DOI
  5. 2013, Progress in cardiovascular diseases, 55, 410, 10.1016/j.pcad.2012.11.009 · DOI
  6. 2010, Europace, 12, 1475, 10.1093/europace/euq302 · DOI
  7. Parry, 2010, Heart, 96, 1611, 10.1136/hrt.2010.193417 · DOI
  8. Muller, 2009, Journal of Telemedicine and Telecare, 15, 391, 10.1258/jtt.2009.090402 · DOI
  9. 2013, Journal of the neurological sciences, 324, 57, 10.1016/j.jns.2012.10.001 · DOI
  10. 2011, 8, S161
  11. Dion, 2010, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 28, 101, 10.1007/s10840-010-9485-5 · DOI · Paper page
  12. Gula, 2004, American heart journal, 147, 644, 10.1016/j.ahj.2003.10.036 · DOI
  13. Gula, 2009, Pacing and clinical electrophysiology : PACE, 32, 466, 10.1111/j.1540-8159.2009.02306.x · DOI
  14. Albright, 2011, 2011, 5625
  15. 2012, Europace, 14, 402, 10.1093/europace/eur343 · DOI · Paper page
  16. Hoch, 2006, BMC health services research [electronic resource], 6, 68, 10.1186/1472-6963-6-68 · DOI · Paper page

Cited by

See all 53

Metadata

Authors
Locati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M.
Venue
Europace
Published
2013-10-24
Volume
16
Issue
6
Pages
914-922
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2022183225
Cited by
53
References
12
FWCI
4.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations. https://app.cochat.ai/papers/10.1093/europace/eut337
The paper
Locati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M. (2014). Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations. Europace. https://doi.org/10.1093/europace/eut337

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.