Fibronectin, Fibrinogen, and Laminin Act as Mediators of Adherence of Clinical Staphylococcal Isolates to Foreign Material
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Bacterial adherence to polymer surfaces is a required early step in intravenous (iv) device infection. We collected eight strains of Staphylococcus aureus and 19 of coagulase-negative staphylococci from patients with proven iv device bacteremia and studied the role of plasma or connective-tissue proteins in promoting bacterial adherence to polymethylmethacrylate (PMMA) coverslips. Although only a negligible percentage of organisms adhered to albumin-coated PMMA, surface-bound fibronectin significantly promoted adherence of all isolates. Fibrinogen markedly promoted adherence of all S. aureus strains but of only four coagulase-negative strains. Thus, coagulase-negative staphylococci revealed a marked heterogeneity in adherence to fibrinogen-coated surfaces, a result suggesting the existence of heretofore unknown receptors for fibrinogen. Laminin promoted adherence of staphylococci to a much lower extent. Although strain specific, adherence of clinical staphylococcal isolates to foreign surfaces is significantly increased by fibronectin, fibrinogen, and laminin, an observation suggesting the possible contribution of these proteins to the pathogenesis of iv device infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleavage of Structural Proteins during the Assembly of the Head of Bacteriophage T4
LAEMMLI, U. K. (1970) · Nature · doi:10.1038/227680a0 · Cited by 249,961
Laminin–a glycoprotein from basement membranes
Timpl, R., Rohde, H., Robey, P. G., Rennard, S. I., Foidart, J. M., & Martin, G. R. (1979) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83607-4 · Cited by 2,378
Christensen, G. D., Simpson, W. A., Younger, J. J., Baddour, L. M., Barrett, F. F., Melton, D. M., & Beachey, E. H. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.22.6.996-1006.1985 · Cited by 2,255
Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces
Christensen, G. D., Simpson, W. A., Bisno, A. L., & Beachey, E. H. (1982) · Infection and Immunity · doi:10.1128/iai.37.1.318-326.1982 · Cited by 1,410
The Bacterial Glycocalyx in Nature and Disease
Costerton, J. W., Irvin, R. T., & Cheng, K. J. (1981) · Annual Review of Microbiology · doi:10.1146/annurev.mi.35.100181.001503 · Cited by 1,053
Doolittle, R. F. (1984) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.53.070184.001211 · Cited by 728
Adherence and Growth of Coagulase-Negative Staphylococci on Surfaces of Intravenous Catheters
Peters, G., Locci, R., & Pulverer, G. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.479 · Cited by 559
Self-citationFibronectin binds to Staphylococcus aureus
KUUSELA, P. (1978) · Nature · doi:10.1038/276718a0 · Cited by 454
Presence of Laminin Receptors in Staphylococcus aureus
Lopes, J. D., dos Reis, M., & Brentani, R. R. (1985) · Science · doi:10.1126/science.3160113 · Cited by 269
Cloning and expression of the gene for a fibronectin-binding protein from Staphylococcus aureus.
Flock, J. I., Fröman, G., Jönsson, K., Guss, B., Signäs, C., Nilsson, B., Raucci, G., Höök, M., Wadström, T., & Lindberg, M. (1987) · The EMBO Journal · doi:10.1002/j.1460-2075.1987.tb02511.x · Cited by 257
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
Bacterial adhesion: seen any good biofilms lately
Dunne, W. M. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.155-166.2002 · Cited by 1,516
Laboratory of Biomechanics and Biomedical Engineering, D. O. M. E., Katsikogianni, M., & Missirlis, Y. (2004) · European Cells and Materials · doi:10.22203/ecm.v008a05 · Cited by 1,178
Concise review of mechanisms of bacterial adhesion to biomaterial surfaces
An, Y. H., & Friedman, R. J. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199823)43:3<338::aid-jbm16>3.0.co;2-b · Cited by 1,146
Pathogenesis of infections due to coagulasenegative staphylococci
von Eiff, C., Peters, G., & Heilmann, C. (2002) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(02)00438-3 · Cited by 1,039
Self-citationStaphylococcus aureus biofilms: Properties, regulation, and roles in human disease
Archer, N. K., Mazaitis, M. J., Costerton, J. W., Leid, J. G., Powers, M. E., & Shirtliff, M. E. (2011) · Virulence · doi:10.4161/viru.2.5.17724 · Cited by 1,018
Mack, D., Fischer, W., Krokotsch, A., Leopold, K., Hartmann, R., Egge, H., & Laufs, R. (1996) · Journal of Bacteriology · doi:10.1128/jb.178.1.175-183.1996 · Cited by 885
Ribeiro, M., Monteiro, F. J., & Ferraz, M. P. (2012) · Biomatter · doi:10.4161/biom.22905 · Cited by 824
Bacterial adhesion: From mechanism to control
Hori, K., & Matsumoto, S. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.11.014 · Cited by 799
Staphylococcal Biofilm Development: Structure, Regulation, and Treatment Strategies
Schilcher, K., & Horswill, A. R. (2020) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00026-19 · Cited by 706
Heilmann, C., Hussain, M., Peters, G., & Götz, F. (1997) · Molecular Microbiology · doi:10.1046/j.1365-2958.1997.4101774.x · Cited by 700
“…proteins such as fibrinogen, fibronectin, vitronectin, and thrombospondin deposited on the implanted material are thought to play an important role in adherence of Staphylococcus aureus to polymer surfaces (Kochwa et al., 1977; Chhatwal et al., 1987; Herrmann et al., 1988; Herrmann et al., 1991).”
BackgroundInfluentialSelf-citationShirtliff, M. E., & Mader, J. T. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.4.527-544.2002 · Cited by 652
Propionibacterium acnes: from Commensal to Opportunistic Biofilm-Associated Implant Pathogen
Achermann, Y., Goldstein, E. J. C., Coenye, T., & Shirtliff, M. E. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00092-13 · Cited by 635
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Lew, D. P., & Waldvogel, F. A. (1997) · New England Journal of Medicine · doi:10.1056/nejm199704033361406 · Cited by 617
Self-citationRaad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.2.400 · Cited by 553
Antimicrobial susceptibility testing in biofilm-growing bacteria
Macia, M. D., Rojo-Molinero, E., & Oliver, A. (2014) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12651 · Cited by 537
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
The Relationship Between the Thrombotic and Infectious Complications of Central Venous Catheters
Raad, I. I. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510370066034 · Cited by 493
Clinical presentation and treatment of orthopaedic implant‐associated infection
Zimmerli, W. (2014) · Journal of Internal Medicine · doi:10.1111/joim.12233 · Cited by 481
Infections Associated with Medical Devices: Pathogenesis, Management and Prophylaxis
von Eiff, C., Jansen, B., Kohnen, W., & Becker, K. (2005) · Drugs · doi:10.2165/00003495-200565020-00003 · Cited by 459
Infectious Complications of Indwelling Vascular Catheters
Raad, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 446
Clinical Microbiology of Bacterial and Fungal Sepsis in Very-Low-Birth-Weight Infants
Kaufman, D., & Fairchild, K. D. (2004) · Clinical Microbiology Reviews · doi:10.1128/cmr.17.3.638-680.2004 · Cited by 435
Mutation of sarA in Staphylococcus aureus Limits Biofilm Formation
Beenken, K. E., Blevins, J. S., & Smeltzer, M. S. (2003) · Infection and Immunity · doi:10.1128/iai.71.7.4206-4211.2003 · Cited by 429
Osteomyelitis and the role of biofilms in chronic infection
Brady, R. A., Leid, J. G., Calhoun, J. H., Costerton, J. W., & Shirtliff, M. E. (2008) · FEMS Immunology & Medical Microbiology · doi:10.1111/j.1574-695x.2007.00357.x · Cited by 400
Harris, L. G., Tosatti, S., Wieland, M., Textor, M., & Richards, R. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.033 · Cited by 393
Staphylococci and implant surfaces: a review
Harris, L. G., & Richards, R. G. (2006) · Injury · doi:10.1016/j.injury.2006.04.003 · Cited by 385
Balancing osteoblast functions and bacterial adhesion on functionalized titanium surfaces
Neoh, K. G., Hu, X., Zheng, D., & Kang, E. T. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.018 · Cited by 330
Cheung, A. L., Eberhardt, K. J., Chung, E., Yeaman, M. R., Sullam, P. M., Ramos, M., & Bayer, A. S. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117530 · Cited by 327
Emerging rules for effective antimicrobial coatings
Salwiczek, M., Qu, Y., Gardiner, J., Strugnell, R. A., Lithgow, T., McLean, K. M., & Thissen, H. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2013.09.008 · Cited by 312
Antimicrobial and Antifouling Strategies for Polymeric Medical Devices
Zander, Z. K., & Becker, M. L. (2018) · ACS Macro Letters · doi:10.1021/acsmacrolett.7b00879 · Cited by 310
Mimicking biofilm formation and development: Recent progress in in vitro and in vivo biofilm models
Guzmán-Soto, I., McTiernan, C., Gonzalez-Gomez, M., Ross, A., Gupta, K., Suuronen, E. J., Mah, T.-F., Griffith, M., & Alarcon, E. I. (2021) · iScience · doi:10.1016/j.isci.2021.102443 · Cited by 309
Implantable Device-Related Infection
VanEpps, J. S., & Younger, J. G. (2016) · Shock · doi:10.1097/shk.0000000000000692 · Cited by 306
Knobloch, J. K.-M., Bartscht, K., Sabottke, A., Rohde, H., Feucht, H.-H., & Mack, D. (2001) · Journal of Bacteriology · doi:10.1128/jb.183.8.2624-2633.2001 · Cited by 300
Lalani, R., & Liu, L. (2012) · Biomacromolecules · doi:10.1021/bm300345e · Cited by 275
Intravascular Catheter-Associated Infections
Crump, J. A., & Collignon, P. J. (2000) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s100960050001 · Cited by 252
Bioadhesion in the oral cavity and approaches for biofilm management by surface modifications
Sterzenbach, T., Helbig, R., Hannig, C., & Hannig, M. (2020) · Clinical Oral Investigations · doi:10.1007/s00784-020-03646-1 · Cited by 212
Synthesis and characterization of non-leaching biocidal polyurethanes
Grapski, J. A., & Cooper, S. L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00412-9 · Cited by 109
Metadata
- Authors
- Herrmann, M., Vaudaux, P. E., Pittet, D., Auckenthaler, R., Lew, P. D., Perdreau, F. S., Peters, G., & Waldvogel, F. A.
- Venue
- The Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-10
- Volume
- 158
- Issue
- 4
- Pages
- 693-701
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2130577876
- Cited by
- 522
- References
- 37
- FWCI
- 15.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.