Closed-Loop Control of Carbon Dioxide Concentration and Pressure Improves Response of Room Respiration Calorimeters
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Large room calorimeters are capable of rapid measurements that are usually made in hoods or small rooms. We evaluated the performance gains of four calorimeters constructed with modern control systems, sample gas preparation and data processing. Calibration of the calorimeters and instruments was performed in place, with traceability to international standards. Performance was evaluated by infusion of N2-CO2 gas and 243 24-h studies of individuals. Our subjects included children weighing 20 kg and adults engaged in heavy exercise. Errors for 24-h infusion measurements (n = 23) were -0.34 +/- 1.24% for oxygen consumption rate and 0.11 +/- 0.98% for carbon dioxide production rate. Calorimeter 90% response times were 2 to 6 min over a range of oxygen consumption rates from 100 to > 4000 mL/min. Closed-loop control of supply and exhaust air flows provided consistent 24-h mean CO2 levels (0.39 +/- 0.015%) and pressures (13.2 +/- 4.4 Pa). Room calorimeters operated with closed-loop control can be used for accurate measurement of energy expenditure rate dynamics for a wide range of individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
Determinants of 24-hour energy expenditure in man. Methods and results using a respiratory chamber.
Ravussin, E., Lillioja, S., Anderson, T. E., Christin, L., & Bogardus, C. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112749 · Cited by 1,166
Cited by
Validation and Calibration of Physical Activity Monitors in Children
Puyau, M. R., Adolph, A. L., Vohra, F. A., & Butte, N. F. (2002) · Obesity Research · doi:10.1038/oby.2002.24 · Cited by 1,023
Self-citationProfound obesity associated with a balanced translocation that disrupts the SIM1 gene
Jr, J. L. (2000) · Human Molecular Genetics · doi:10.1093/hmg/9.1.101 · Cited by 401
Energy requirements during pregnancy based on total energy expenditure and energy deposition
Butte, N. F., Wong, W. W., Treuth, M. S., Ellis, K. J., & O'Brian Smith, E. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.6.1078 · Cited by 309
Self-citationPrediction of Energy Expenditure and Physical Activity in Preschoolers
BUTTE, N. F., WONG, W. W., LEE, J. S., ADOLPH, A. L., PUYAU, M. R., & ZAKERI, I. F. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000209 · Cited by 273
Self-citationA dual-respiration chamber system with automated calibration
Schoffelen, P. F. M., Westerterp, K. R., Saris, W. H. M., & Ten Hoor, F. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2064 · Cited by 252
“The equations used in the calculation of gas exchange are based on the assumption of N2 conservation [‘‘haldane’’ correction (3, 5, 7, 10–12, 15–17)] with incorporation of differentiated changes in the chamber volume for the N2 equation [dFN2/dt; determined at the outlet (3, 7, 12, 17)].”
BackgroundMethodInfluentialAdjustments in energy expenditure and substrate utilization during late pregnancy and lactation
Butte, N. F., Hopkinson, J. M., Mehta, N., Moon, J. K., & Smith, E. O. (1999) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.2.299 · Cited by 245
Self-citationThe mass-specific energy cost of human walking is set by stature
Weyand, P. G., Smith, B. R., Puyau, M. R., & Butte, N. F. (2010) · Journal of Experimental Biology · doi:10.1242/jeb.048199 · Cited by 85
Self-citationZakeri, I., Adolph, A. L., Puyau, M. R., Vohra, F. A., & Butte, N. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01163.2007 · Cited by 80
Self-citationEnergetic adaptations persist after bariatric surgery in severely obese adolescents
Butte, N. F., Brandt, M. L., Wong, W. W., Liu, Y., Mehta, N. R., Wilson, T. A., Adolph, A. L., Puyau, M. R., Vohra, F. A., Shypailo, R. J., et al. (2015) · Obesity · doi:10.1002/oby.20994 · Cited by 55
Self-citationAre basal metabolic rate prediction equations appropriate for female children and adolescents?
Wong, W. W., Butte, N. F., Hergenroeder, A. C., Hill, R. B., Stuff, J. E., & Smith, E. O. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2407 · Cited by 53
Self-citationNguyen, T., de Jonge, L., Smith, S. R., & Bray, G. A. (2003) · Medical and Biological Engineering and Computing · doi:10.1007/bf02345320 · Cited by 47
Metadata
- Authors
- Moon, J. K., Vohra, F. A., Jimenez, O. S. V., Puyau, M. R., & Butte, N. F.
- Venue
- The Journal of Nutrition
- Publisher
- Elsevier BV
- Published
- 1995-02
- Volume
- 125
- Issue
- 2
- Pages
- 220-228
- ISSN
- 0022-3166 (ISSN-L)
- OpenAlex
- W1499068454
- Cited by
- 80
- References
- 2
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.