A new mathematical model for relative quantification in real-time RT-PCR
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Use of the real-time polymerase chain reaction (PCR) to amplify cDNA products reverse transcribed from mRNA is on the way to becoming a routine tool in molecular biology to study low abundance gene expression. Real-time PCR is easy to perform, provides the necessary accuracy and produces reliable as well as rapid quantification results. But accurate quantification of nucleic acids requires a reproducible methodology and an adequate mathematical model for data analysis. This study enters into the particular topics of the relative quantification in real-time RT-PCR of a target gene transcript in comparison to a reference gene transcript. Therefore, a new mathematical model is presented. The relative expression ratio is calculated only from the real-time PCR efficiencies and the crossing point deviation of an unknown sample versus a control. This model needs no calibration curve. Control levels were included in the model to standardise each reaction run with respect to RNA integrity, sample loading and inter-PCR variations. High accuracy and reproducibility (<2.5% variation) were reached in LightCycler PCR using the established mathematical model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“alternative, more generalized quantitative models have been developed to correct for differences in amplification efficiency (62 ) and to allow the use of multiple reference genes (30 ).”
From The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments (2009) · cites this paper as [62]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
A novel method for real time quantitative RT-PCR.
Gibson, U. E., Heid, C. A., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.995 · Cited by 2,075
Quantitation of mRNA by the polymerase chain reaction.
Wang, A. M., Doyle, M. V., & Mark, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.24.9717 · Cited by 1,625
Housekeeping genes as internal standards: use and limits
Thellin, O., Zorzi, W., Lakaye, B., De Borman, B., Coumans, B., Hennen, G., Grisar, T., Igout, A., & Heinen, E. (1999) · Journal of Biotechnology · doi:10.1016/s0168-1656(99)00163-7 · Cited by 1,544
Quantitative RT-PCR: Pitfalls and Potential
Freeman, W. M., Walker, S. J., & Vrana, K. E. (1999) · BioTechniques · doi:10.2144/99261rv01 · Cited by 1,147
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Quantification on the LightCycler
Rasmussen, R. (2001) · Rapid Cycle Real-Time PCR · doi:10.1007/978-3-642-59524-0_3 · Cited by 892
Rapid Cycle Real-Time PCR: Methods and Applications
Wittwer, C. (2001) · Rapid Cycle Real-Time PCR · doi:10.1007/978-3-642-59524-0_1 · Cited by 630
QUANTIFICATION OF MURINE CYTOKINE mRNAs USING REAL TIME QUANTITATIVE REVERSE TRANSCRIPTASE PCR
Overbergh, L., Valckx, D., Waer, M., & Mathieu, C. (1999) · Cytokine · doi:10.1006/cyto.1998.0426 · Cited by 557
Quantitative or semi-quantitative PCR: reality versus myth.
Ferre, F. (1992) · Genome Research · doi:10.1101/gr.2.1.1 · Cited by 349
Developments in Quantitative PCR
Orlando, C., Pinzani, P., & Pazzagli, M. (1998) · cclm · doi:10.1515/cclm.1998.045 · Cited by 333
Pfaffl, M. W., & Hageleit, M. (2001) · Biotechnology Letters · doi:10.1023/a:1005658330108 · Cited by 296
Self-citationNitric oxide stimulates auto-ADP-ribosylation of glyceraldehyde-3-phosphate dehydrogenase.
Zhang, J., & Snyder, S. H. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.20.9382 · Cited by 283
Quantitative RT-PCR: Limits and Accuracy
Souazé, F., Ntodou-Thomé, A., Tran, C. Y., Rostène, W., & Forgez, P. (1996) · BioTechniques · doi:10.2144/96212rr01 · Cited by 194
Bhatia, P., Taylor, W. R., Greenberg, A. H., & Wright, J. A. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1028 · Cited by 181
Foss, D. L., Baarsch, M. J., & Murtaugh, M. P. (1998) · Animal Biotechnology · doi:10.1080/10495399809525893 · Cited by 173
Effect of amino acid limitation on the expression of 19 genes in rat hepatoma cells
Marten, N. W., Burke, E. J., Hayden, J. M., & Straus, D. S. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.8.8181673 · Cited by 141
Evaluation of RNA Isolation Methods and Reference Genes for RT-PCR Analyses of Rare Target RNA
Mannhalter, C., Koizar, D., & Mitterbauer, G. (2000) · cclm · doi:10.1515/cclm.2000.026 · Cited by 81
Up-regulation of beta-actin, cyclophilin and GAPDH in N1S1 rat hepatoma.
Chang, T. J., Juan, C. C., Yin, P., Chi, C. W., & Tsay, H.-J. (1998) · Oncology Reports · doi:10.3892/or.5.2.469 · Cited by 80
Pfaffl, M. W. (2001) · Springer eBooks · doi:10.1007/978-3-642-59524-0_30 · Cited by 74
Self-citationBereta, J., & Bereta, M. (1995) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1995.2785 · Cited by 68
Pfaffl, M. W., MEYER, H. H. D., & Sauerwein, H. (2009) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-0029-1212025 · Cited by 42
Self-citationWong, L., Pearson, H., Fletcher, A., Marquis, C. P., & Mahler, S. M. (1998) · Biotechnology Techniques · doi:10.1023/a:1008871608947 · Cited by 17
Research works printed but not linked: 2
- [15]15. Zhang,J. and Snyder,S.H. (1992) Nitric oxide stimulates auto-ADPribosylation of glyceraldehydes 3 phosphate dehydrogenase. Proc. Natl Acad. Sci. USA , 89 , 9382-9385.
- [26]26. Wong,L., Pearson,H., Fletcher,A., Marquis,C.P. and Mahler,S. (1998) Comparison of the efficiency of M-MuLV reverse transcriptase, RNase H M-MuLV reverse transcriptase and AMV reverse transcriptase for the amplification of human immunglobulin genes. Biotechnol. Techniques , 12 , 485-489.
Cited by
Analyzing real-time PCR data by the comparative CT method
Schmittgen, T. D., & Livak, K. J. (2008) · Nature Protocols · doi:10.1038/nprot.2008.73 · Cited by 26,190
“The efficiency correction method calculates the relative expression ratio from the real-time PCR efficiencies and the C T (ref”
MethodThe MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationPfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,376
Self-citationPfaffl, M. W., Tichopad, A., Prgomet, C., & Neuvians, T. P. (2004) · Biotechnology Letters · doi:10.1023/b:bile.0000019559.84305.47 · Cited by 5,065
“Reporting of the amount of target mRNA requires an accurate template preparation and relevant standardisation (Pfaffl 2001).”
MethodInfluentialSelf-citationHellemans, J., Mortier, G., De Paepe, A., Speleman, F., & Vandesompele, J. (2007) · Genome Biology · doi:10.1186/gb-2007-8-2-r19 · Cited by 4,023
Metadata
- Authors
- Pfaffl, M. W.
- Affiliations
- Technical University of Munich (DE)
- Corresponding author
- Pfaffl, M. W.
- ORCID
- Pfaffl, M. W.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-05-01
- Volume
- 29
- Issue
- 9
- Pages
- 45e-45
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- PMC
- PMC55695
- OpenAlex
- W2108244474
- Cited by
- 34,610
- References
- 26
- Citations by year
- 2026: 1039 · 2025: 1447 · 2024: 1720 · 2023: 1758 · 2022: 1762 · 2021: 1930 · 2020: 2041 · 2019: 1965 · 2018: 1840 · 2017: 1924 · 2016: 1898 · 2015: 1932 · 2014: 2005 · 2013: 1982 · 2012: 1780
- FWCI
- 42.90
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Nucleic Acids Research (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › RNA Research and Splicing
- Keywords
- relative quantification, real-time RT-PCR, mathematical model, PCR efficiency, reference genes, gene expression normalization, calibration-free quantification, LightCycler
- MeSH terms
- Animals, Gene Expression Regulation, Models, Theoretical, Reference Standards, RNA, Messenger, Sensitivity and Specificity, Time Factors, Transcription, Genetic, Reproducibility of Results, DNA Primers, Reverse Transcriptase Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.