The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Standardized determination of real-time PCR efficiency from a single reaction set-up
Open accessAbstract
We propose a computing method for the estimation of real-time PCR amplification efficiency. It is based on a statistic delimitation of the beginning of exponentially behaving observations in real-time PCR kinetics. PCR ground fluorescence phase, non-exponential and plateau phase were excluded from the calculation process by separate mathematical algorithms. We validated the method on experimental data on multiple targets obtained on the LightCycler platform. The developed method yields results of higher accuracy than the currently used method of serial dilutions for amplification efficiency estimation. The single reaction set-up estimation is sensitive to differences in starting concentrations of the target sequence in samples. Furthermore, it resists the subjective influence of researchers, and the estimation can therefore be fully instrumentalized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Pfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,376
Applied Linear Statistical Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485141 · Cited by 7,185
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,654
Housekeeping genes as internal standards: use and limits
Thellin, O., Zorzi, W., Lakaye, B., De Borman, B., Coumans, B., Hennen, G., Grisar, T., Igout, A., & Heinen, E. (1999) · Journal of Biotechnology · doi:10.1016/s0168-1656(99)00163-7 · Cited by 1,544
Schmittgen, T. D., & Zakrajsek, B. A. (2000) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(00)00129-9 · Cited by 1,242
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Cited by
Pfaffl, M. W., Tichopad, A., Prgomet, C., & Neuvians, T. P. (2004) · Biotechnology Letters · doi:10.1023/b:bile.0000019559.84305.47 · Cited by 5,065
Self-citationAmplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
“In contrast, analysis methods based on nonlinear curve fitting do not require such an a priori baseline subtraction because the fitted mathematical models contain an additive term (i.e. y 0 or F b ) that represents a constant (6,27,28) or cycle-dependent baseline (5,19).”
Quantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247
Statistical analysis of real-time PCR data
Yuan, J. S., Reed, A., Chen, F., & Stewart, C. N. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-85 · Cited by 2,195
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
RNA integrity and the effect on the real-time qRT-PCR performance
Fleige, S., & Pfaffl, M. W. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.003 · Cited by 1,487
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303
Neuropathology of patients with COVID-19 in Germany: a post-mortem case series
Matschke, J., Lütgehetmann, M., Hagel, C., Sperhake, J. P., Schröder, A. S., Edler, C., Mushumba, H., Fitzek, A., Allweiss, L., Dandri, M., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(20)30308-2 · Cited by 1,300
A standard curve based method for relative real time PCR data processing
Larionov, A., Krause, A., & Miller, W. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-62 · Cited by 946
Schefe, J. H., Lehmann, K. E., Buschmann, I. R., Unger, T., & Funke-Kaiser, H. (2006) · Journal of Molecular Medicine · doi:10.1007/s00109-006-0097-6 · Cited by 859
Svec, D., Tichopad, A., Novosadova, V., Pfaffl, M. W., & Kubista, M. (2015) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2015.01.005 · Cited by 601
Self-citationFleige, S., Walf, V., Huch, S., Prgomet, C., Sehm, J., & Pfaffl, M. W. (2006) · Biotechnology Letters · doi:10.1007/s10529-006-9127-2 · Cited by 580
Schmidt, G. W., & Delaney, S. K. (2010) · Molecular Genetics and Genomics · doi:10.1007/s00438-010-0511-1 · Cited by 553
Stricker, A. R., Grosstessner-Hain, K., Würleitner, E., & Mach, R. L. (2006) · Eukaryotic Cell · doi:10.1128/ec.00211-06 · Cited by 417
Properties of the Reverse Transcription Reaction in mRNA Quantification
Ståhlberg, A., Håkansson, J., Xian, X., Semb, H., & Kubista, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026161 · Cited by 409
“, comparing the expression of genes in different samples, are possible by compensating for sample-to-sample variation in PCR efficiency by, for example, in situ calibration (2 ) or kinetic PCR (34, 35).”
BackgroundRitz, C., & Spiess, A.-N. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn227 · Cited by 391
Why the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
Specific and sensitive quantitative RT-PCR of miRNAs with DNA primers
Balcells, I., Cirera, S., & Busk, P. K. (2011) · BMC Biotechnology · doi:10.1186/1472-6750-11-70 · Cited by 308
Luu-The, V., Paquet, N., Calvo, E., & Cumps, J. (2005) · BioTechniques · doi:10.2144/05382rr05 · Cited by 284
Idzko, M., Panther, E., Stratz, C., Müller, T., Bayer, H., Zissel, G., Dürk, T., Sorichter, S., Di Virgilio, F., Geissler, M., et al. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.10.6011 · Cited by 272
Spandidos, A., Wang, X., Wang, H., Dragnev, S., Thurber, T., & Seed, B. (2008) · BMC Genomics · doi:10.1186/1471-2164-9-633 · Cited by 269
Steibel, J. P., Poletto, R., Coussens, P. M., & Rosa, G. J. M. (2009) · Genomics · doi:10.1016/j.ygeno.2009.04.008 · Cited by 260
Ruijter, J. M., Pfaffl, M. W., Zhao, S., Spiess, A. N., Boggy, G., Blom, J., Rutledge, R. G., Sisti, D., Lievens, A., De Preter, K., et al. (2013) · Methods · doi:10.1016/j.ymeth.2012.08.011 · Cited by 258
SPUD: A quantitative PCR assay for the detection of inhibitors in nucleic acid preparations
Nolan, T., Hands, R. E., Ogunkolade, W., & Bustin, S. A. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.051 · Cited by 257
Differential susceptibility of PCR reactions to inhibitors: an important and unrecognised phenomenon
Huggett, J. F., Novak, T., Garson, J. A., Green, C., Morris-Jones, S. D., Miller, R. F., & Zumla, A. (2008) · BMC Research Notes · doi:10.1186/1756-0500-1-70 · Cited by 250
“Background It is well known that the polymerase chain reaction (PCR) is susceptible to inhibitors [1-4] and many publications describe methods for assessing inhibition using spiked alien molecules of various types [5-9].”
BackgroundHou, Y., Zhang, H., Miranda, L., & Lin, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009545 · Cited by 222
Benefits of higher resistance-training volume are related to ribosome biogenesis
Hammarström, D., Øfsteng, S., Koll, L., Hanestadhaugen, M., Hollan, I., Apró, W., Whist, J. E., Blomstrand, E., Rønnestad, B. R., & Ellefsen, S. (2020) · The Journal of Physiology · doi:10.1113/jp278455 · Cited by 99
Dijkstra, J. R., van Kempen, L. C., Nagtegaal, I. D., & Bustin, S. A. (2014) · Molecular Oncology · doi:10.1016/j.molonc.2013.12.016 · Cited by 59
Qi, L., Li, J., Zhang, W., Liu, J., Rong, C., Li, Y., & Wu, L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029572 · Cited by 45
“Fold amplification was calculated by comparative threshold cycle (CT) method [30,31].”
MethodWei, J., Antony, J., Meng, F., MacLean, P., Rhind, R., Laible, G., & Oback, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-06569-2 · Cited by 39
Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data
Tellinghuisen, J., & Spiess, A.-N. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02057 · Cited by 35
Metadata
- Authors
- Tichopad, A.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-10-15
- Volume
- 31
- Issue
- 20
- Pages
- 122e-122
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2099206288
- Cited by
- 455
- References
- 23
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.