Clinical Measurement of Range of Motion
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Clinical measurement of range of motion is a fundamental evaluation procedure with ubiquitous application in physical therapy. Objective measurements of ROM and correct interpretation of the measurement results can have a substantial impact on the development of the scientific basis of therapeutic interventions. The purpose of this article is to review the related literature on the reliability and validity of goniometric measurements of the extremities. Special emphasis is placed on how the reliability of goniometry is influenced by instrumentation and procedures, differences among joint actions and body regions, passive versus active measurements, intratester versus intertester measurements, and different patient types. Our discussion of validity encourages objective interpretation of the meaning of ROM measurements in light of the purposes and the limitations of goniometry. We conclude that clinicians should adopt standardized methods of testing and should interpret and report goniometric results as ROM measurements only, not as measurements of factors that may affect ROM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of Joint Motion: A guide to goniometry
Norkin, C. C., & White, D. (1985) · Medical Entomology and Zoology · Cited by 1,118
Reliability of Goniometric Measurements
Boone, D. C., Azen, S. P., Lin, C.-M., Spence, C., Baron, C., & Lee, L. (1978) · Physical Therapy · doi:10.1093/ptj/58.11.1355 · Cited by 560
Physical examination of the spine and extremities
Hoppenfeld, S. (1979) · Medical Entomology and Zoology · Cited by 546
Goniometric Reliability in a Clinical Setting
Rothstein, J. M., Miller, P. J., & Roettger, R. F. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1611 · Cited by 546
Biomechanical analysis of knee flexion and extension
Smidt, G. L. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90040-7 · Cited by 511
Freedman, L., & Munro, R. R. (1966) · PubMed · Cited by 297
Elements of Research in Physical Therapy
Currier, D. P. (1984) · Medical Entomology and Zoology · Cited by 259
Lower extremity goniometric measurements: a study to determine their reliability.
Ekstrand, J., Wiktorsson, M., Öberg, B. E., & Gillquist, J. (1982) · PubMed · Cited by 253
Gajdosik, R., & Lusin, G. (1983) · Physical Therapy · doi:10.1093/ptj/63.7.1085 · Cited by 253
Self-citationReliability of Goniometric Measurements in Patients with Duchenne Muscular Dystrophy
Pandya, S., Florence, J. M., King, W. M., Robison, J. D., Oxman, M., & Province, M. A. (1985) · Physical Therapy · doi:10.1093/ptj/65.9.1339 · Cited by 127
Cited by
Ferrucci, L., Bandinelli, S., Benvenuti, E., Di Iorio, A., Macchi, C., Harris, T. B., & Guralnik, J. M. (2000) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb03873.x · Cited by 804
Eliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K. (1994) · Physical Therapy · doi:10.1093/ptj/74.8.777 · Cited by 635
Passive extensibility of skeletal muscle: review of the literature with clinical implications
Gajdosik, R. L. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00061-9 · Cited by 535
Self-citationReliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods
Youdas, J. W., Carey, J. R., & Garrett, T. R. (1991) · Physical Therapy · doi:10.1093/ptj/71.2.98 · Cited by 514
Passive properties of human skeletal muscle during stretch maneuvers
Magnusson, S. P. (1998) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.1998.tb00171.x · Cited by 399
Normal Hip and Knee Active Range of Motion: The Relationship to Age
Roach, K. E., & Miles, T. P. (1991) · Physical Therapy · doi:10.1093/ptj/71.9.656 · Cited by 357
The clinical effects of Kinesio®Tex taping: A systematic review
Morris, D., Jones, D., Ryan, H., & Ryan, C. G. (2013) · Physiotherapy Theory and Practice · doi:10.3109/09593985.2012.731675 · Cited by 337
Risk Factors for the Development of Low Back Pain in Adolescence
Feldman, D. E. (2001) · American Journal of Epidemiology · doi:10.1093/aje/154.1.30 · Cited by 330
Muscle soreness, swelling, stiffness and strength loss after intense eccentric exercise.
Cleak, M. J., & Eston, R. G. (1992) · British Journal of Sports Medicine · doi:10.1136/bjsm.26.4.267 · Cited by 294
Measuring Function of the Shoulder. A Cross-Sectional Comparison of Five Questionnaires*
BEATON, D. E., & RICHARDS, R. R. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199606000-00011 · Cited by 275
TURCHIN, D. C., BEATON, D. E., & RICHARDS, R. R. (1998) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199802000-00002 · Cited by 271
Reliability of shoulder range of motion comparing a goniometer to a digital level
Mullaney, M. J., McHugh, M. P., Johnson, C. P., & Tyler, T. F. (2010) · Physiotherapy Theory and Practice · doi:10.3109/09593980903094230 · Cited by 265
Nussbaumer, S., Leunig, M., Glatthorn, J. F., Stauffacher, S., Gerber, H., & Maffiuletti, N. A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-194 · Cited by 262
Upstream Dysfunction of Somatomotor Functional Connectivity After Corticospinal Damage in Stroke
Carter, A. R., Patel, K. R., Astafiev, S. V., Snyder, A. Z., Rengachary, J., Strube, M. J., Pope, A., Shimony, J. S., Lang, C. E., Shulman, G. L., et al. (2012) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968311411054 · Cited by 199
“Degrees of shoulder flexion, wrist flexion, and wrist extension.(41) Grip strength.”
BackgroundI am a Smartwatch and I can Track my User's Arm
Shen, S., Wang, H., & Roy Choudhury, R. (2016) · Proceedings of the 14th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/2906388.2906407 · Cited by 184
Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400018411 · Cited by 179
Keogh, J. W. L., Cox, A., Anderson, S., Liew, B., Olsen, A., Schram, B., & Furness, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0215806 · Cited by 159
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
The Case for Retiring Flexibility as a Major Component of Physical Fitness
Nuzzo, J. L. (2020) · Sports Medicine · doi:10.1007/s40279-019-01248-w · Cited by 127
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
“Low inter-rater reliability is thought to result from the complexity and characteristics of the movement, the anatomical joint being measured, and the level of assessor experience [5, 6].”
BackgroundClinical Reliability and Usability of Smartphone Goniometers for Hip Range of Motion Measurement
Takeda, Y., & Furukawa, K. (2022) · Journal of Physical Therapy Science · doi:10.1589/jpts.34.433 · Cited by 10
Metadata
- Authors
- Gajdosik, R. L., & Bohannon, R. W.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-12-01
- Volume
- 67
- Issue
- 12
- Pages
- 1867-1872
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2275744032
- Cited by
- 898
- References
- 17
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.