Surface modification of biodegradable magnesium and its alloys for biomedical applications
Open accessThe DOI matches its Crossref record; 125 of the 125 references it cites were found in a registry or an index.
Abstract
Magnesium and its alloys are being paid much attention recently as temporary implants, such as orthopedic implants and cardiovascular stents. However, the rapid degradation of them in physiological environment is a major obstacle preventing their wide applications to date, which will result in rapid mechanical integrity loss or even collapse of magnesium-based implants before injured tissues heal. Moreover, rapid degradation of the magnesium-based implants will also cause some adverse effects to their surrounding environment, such as local gas cavity around the implant, local alkalization and magnesium ion enrichment, which will reduce the integration between implant and tissue. So, in order to obtain better performance of magnesium-based implants in clinical trials, special alloy designs and surface modifications are prerequisite. Actually, when a magnesium-based implant is inserted in vivo, corrosion firstly happens at the implant-tissue interface and the biological response to implant is also determined by the interaction at this interface. So the surface properties, such as corrosion resistance, hemocompatibility and cytocompatibility of the implant, are critical for their in vivo performance. Compared with alloy designs, surface modification is less costly, flexible to construct multi-functional surface and can prevent addition of toxic alloying elements. In this review, we would like to summarize the current investigations of surface modifications of magnesium and its alloys for biomedical application. The advantages/disadvantages of different surface modification methods are also discussed as a suggestion for their utilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2. (a) Surface and cross-sectional morphologies of Mg(OH)2 film by NaOH treatment for 3 h [66]. (b) Digital photographs and FE-SEM images of color-tuned surfaces on AZ31 alloy by water treatment [69]. (c) Surface and cross-sectional morphologies of fluoride-treated AZ31 alloy for 72 h. The insert shows the high magnification [71]. (d) Surface and cross-sectional morphologies of the MAO-coated Mg–Zn–Zr alloy [76]. (e) Surface morphologies of Mg–Fe–CO3 LDH layers on pure magnesium by different treatment process [80].](https://figures.cochat.ai/paper-figures/fb34402ec8e346e5a016c65aff5a9cee/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-2.jpg)
![Figure 3. (a) Surface morphologies of DCPD, HA and FHA on Mg–Zn alloy by electrodeposition process [87]. (b) Surface morphologies of DCPD [92], β-TCP [94] and HA [96] on magnesium substrate by chemical solution treatment. (c) Surface morphologies of DCPD, DCPD-HA and HA on magnesium substrate by biomimetic process [98].](https://figures.cochat.ai/paper-figures/229369952c4f4c43852a582d0ccc1c6b/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-3.jpg)
![Figure 4. (a) Surface morphologies of compact polymer coatings on magnesium substrate [101]. (b) Surface morphologies of porous PCL coatings on AZ91 alloy [35]. (c) Surface morphologies of PEDOT conductive coatings fabricated on magnesium with different processes [104].](https://figures.cochat.ai/paper-figures/12ae3b7073aa4f40a29d2ef03b15e1e8/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-4.jpg)
![Figure 5. (a) Surface and sectional morphologies of DCPD/MgF2 and HA/MgF2 composite coatings on Mg–Ca–Zn alloy [108]. (b) Surface morphologies of WE42, WE42-MAO, WE42-MAO/PLLA and corrosion mass loss of WE42, WE42-MAO/PLLA [109]. (c) Surface morphologies and elemental compositions of MAO and calcification MAO coatings, cross-sectional morphology of calcification MAO coating [111].](https://figures.cochat.ai/paper-figures/3c744567a9264dbd9b8bd37b2fbf2a77/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-5.jpg)
![Figure 6. (a) XPS depth profile of CO2-PIII-treated AZ31 alloy and polarization curves of untreated and CO2-PIII-treated AZ31 alloy in DMEM and SBF [115]. (b) XPS depth profile, polarization curve in SBF and corrosion in SBF for 18 h of Zn-PIII-treated pure Mg [116]. (c) XPS depth profile, GIXRD pattern and polarization curve in SBF of Al-PIII-treated pure Mg [117].](https://figures.cochat.ai/paper-figures/385b653296cc456e9ac5368cc886b26b/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-6.jpg)
![Figure 7. (a) XPS depth profile, polarization curve and EIS spectrum of Al–O dual ion implantation treated WE43 alloy [120]. (b) XPS depth profiles and polarization curves of Ti and Ti–O dual ion implantation treated WE43 alloy [122]. (c) XPS depth profile and polarization curves in SBF and Na2SO4 of Cr–O dual ion implantation treated pure Mg [125].](https://figures.cochat.ai/paper-figures/5209d2478d74464aaddf2a99861eee3c/surface-modification-of-biodegradable-magnesium-and-its-alloys-for-biomedical-figure-7.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Surface modification of magnesium to overcome these drawbacks is the most effective method for controlling corrosion and enhancing bioactivity [36,37].”
From Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating (2026) · cites this paper as [37]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How useful is SBF in predicting in vivo bone bioactivity?
Kokubo, T., & Takadama, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.017 · Cited by 9,576
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundTitanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundSynthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617 · cited 1×
“the degradation process or the corrosion products can induce local inflammation and the products of inflammation can enhance the degradation process [47, 48].”
BackgroundIn vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395 · cited 1×
“The rapid degradation of magnesium implant in vivo also leads to an accumulation of hydrogen nearby the implant because of limited hydrogen gas adsorption ability of the tissues [27, 44].”
BackgroundThe history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860 · cited 1×
“However, although most patients experienced subcutaneous gas cavities by rapid degradation of the implants, they had no pain and almost no infections were observed during the postoperative following up in the early clinical cases [45].”
BackgroundInfluentialDegradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820 · cited 2×
“The rapid degradation of magnesium implant in vivo also leads to an accumulation of hydrogen nearby the implant because of limited hydrogen gas adsorption ability of the tissues [27, 44].”
BackgroundThe development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593 · cited 1×
“Mg–Ca [51, 52], Mg–Zn [53, 54], Mg–Sr [55] and Mg–Ag [56, 57] alloys have been developed by adding single nutrient element or antibacterial element.”
BackgroundSaris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366 · cited 2×
“So the incidence of hyper-magnesium is rare due to the efficient excretion of excess magnesium ions through urine [34].”
Research on an Mg–Zn alloy as a degradable biomaterial
Zhang, S., Zhang, X., Zhao, C., Li, J., Song, Y., Xie, C., Tao, H., Zhang, Y., He, Y., Jiang, Y., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.028 · Cited by 1,336 · cited 9×
“The precipitates on the uncoated and DCPD-coated Mg–Zn alloy in modified simulated biological fluid had low Ca/P molar ratio, which delayed bone-like apatite formation, while both HA and FHA coating could promote the nucleation of osteoconductive minerals for 1 month.”
BackgroundInfluentialAmass, W., Amass, A., & Tighe, B. (1998) · Polymer International · doi:10.1002/(sici)1097-0126(1998100)47:2<89::aid-pi86>3.0.co;2-f · Cited by 1,001 · cited 2×
“Degradable polymers have been applied in various areas including biomedical applications [23, 24].”
BackgroundIncreased osteoblast adhesion on nanophase metals: Ti, Ti6Al4V, and CoCrMo
Webster, T. J., & Ejiofor, J. U. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.002 · Cited by 793 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundVojtěch, D., Kubásek, J., Šerák, J., & Novák, P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.008 · Cited by 708 · cited 1×
“As trace elements existing in the human body, magnesium [28], iron [29] and newly investigated zinc [30]-based materials have been investigated as promising candidates for temporary implant materials.”
BackgroundStress shielding and bone resorption in shoulder arthroplasty
Nagels, J., Stokdijk, M., & Rozing, P. M. (2003) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2003.22 · Cited by 707 · cited 1×
“The stress shielding usually leads the surrounding bone tissue to experience a reduced loading stress, which ultimately leads to bone resorption [22].”
BackgroundCalcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651 · cited 1×
“Many methods have been investigated to fabricate Ca–P-based coatings on magnesium and its alloys [86].”
MethodRole of Magnesium in Genomic Stability
Hartwig, A. (2001) · Mutation Research - Fundamental and Molecular Mechanisms of Mutagenesis · doi:10.1016/s0027-5107(01)00074-4 · Cited by 625 · cited 1×
“Magnesium is a cofactor for many enzymes, and acts as a stabilizer for the structures of DNA and RNA [32].”
BackgroundDevelopments in metallic biodegradable stents☆
Hermawan, H., Dubé, D., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.006 · Cited by 604 · cited 1×
“In orthopedic and cardiovascular stent applications, implants are usually required to undertake a certain load during the healing of injured bone tissues or vascular walls [28, 39].”
BackgroundWong, H. M., Yeung, K. W. K., Lam, K. O., Tam, V., Chu, P. K., Luk, K. D. K., & Cheung, K. M. C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.111 · Cited by 579 · cited 1×
“So the degradation of magnesium-based implants in human body generally will not cause an increased level of serum magnesium [35].”
BackgroundKannan, M. B., & Raman, R. K. S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.02.003 · Cited by 545 · cited 1×
“Pits or cracks caused by rapid corrosion may result in sudden catastrophic and premature cracking causing eventually failure of the implants, even at the initial stage after implantation [40, 41].”
BackgroundClinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Xu, L., Pan, F., Yu, G., Yang, L., Zhang, E., & Yang, K. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.001 · Cited by 505 · cited 1×
“[93] studied the porous and netlike DCPD layer formed on the surface of the Mg alloy.”
BackgroundZhang, E., Yin, D., Xu, L., Yang, L., & Yang, K. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.08.024 · Cited by 480 · cited 2×
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc. complex alloys have also been developed for better performance in mechanical properties and biocompatibility.”
Gu, X. N., Xie, X. H., Li, N., Zheng, Y. F., & Qin, L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.02.018 · Cited by 478 · cited 1×
“Mg–Ca [51, 52], Mg–Zn [53, 54], Mg–Sr [55] and Mg–Ag [56, 57] alloys have been developed by adding single nutrient element or antibacterial element.”
BackgroundLi, L., Gao, J., & Wang, Y. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.01.004 · Cited by 441 · cited 1×
“In cytotoxicity tests, no signs of changes on cell morphology or inhibitory effect on cell growth were detected for this kind of film [67].”
BackgroundThe role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium
Khang, D., Lu, J., Yao, C., Haberstroh, K. M., & Webster, T. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.009 · Cited by 437 · cited 1×
“Moreover, the response of surrounding tissues to the implants is closely related to their surface properties [64].”
BackgroundBiodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response
Witte, F., Ulrich, H., Rudert, M., & Willbold, E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31170 · Cited by 409 · cited 1×
“Although the definite mechanism of the relationship between corrosion process and local inflammation is generally unknown for biodegradable metals, some previous results have shown that fast corroding magnesium alloys respond with a mild foreign body reaction [49, 50].”
ResultElectrodeposition of Ca–P coatings on biodegradable Mg alloy: In vitro biomineralization behavior☆
Song, Y., Zhang, S., Li, J., Zhao, C., & Zhang, X. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.020 · Cited by 385
Fe–Mn alloys for metallic biodegradable stents: Degradation and cell viability studies☆
Hermawan, H., Purnama, A., Dube, D., Couet, J., & Mantovani, D. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.11.025 · Cited by 372 · cited 1×
“As trace elements existing in the human body, magnesium [28], iron [29] and newly investigated zinc [30]-based materials have been investigated as promising candidates for temporary implant materials.”
BackgroundEddy Jai Poinern, G., Brundavanam, S., & Fawcett, D. (2013) · American Journal of Biomedical Engineering · doi:10.5923/j.ajbe.20120206.02 · Cited by 361
Wang, H. X., Guan, S. K., Wang, X., Ren, C. X., & Wang, L. G. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.009 · Cited by 359 · cited 1×
“Pits or cracks caused by rapid corrosion may result in sudden catastrophic and premature cracking causing eventually failure of the implants, even at the initial stage after implantation [40, 41].”
BackgroundSurface design of biodegradable magnesium alloys — A review
Wu, G., Ibrahim, J. M., & Chu, P. K. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2012.10.009 · Cited by 358 · cited 2×
“Hence, a biodegradable dynamic interface should be considered in order to endow the implants with desirable corrosion resistance and surface biocompatibility as well as maintain the mechanical strength of the substrate during service stage [65].”
BackgroundTonino, A., Davidson, C., Klopper, P., & Linclau, L. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b1.1270486 · Cited by 338 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundSafety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
Waksman, R., Pakala, R., Kuchulakanti, P. K., Baffour, R., Hellinga, D., Seabron, R., Tio, F. O., Wittchow, E., Hartwig, S., Harder, C., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20727 · Cited by 330 · cited 1×
“Although the definite mechanism of the relationship between corrosion process and local inflammation is generally unknown for biodegradable metals, some previous results have shown that fast corroding magnesium alloys respond with a mild foreign body reaction [49, 50].”
ResultJanning, C., Willbold, E., Vogt, C., Nellesen, J., Meyer-Lindenberg, A., Windhagen, H., Thorey, F., & Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.12.037 · Cited by 321 · cited 1×
“Moreover, the major corrosion product Mg(OH)2 has been proved to be closely related to the enhanced bone formation and temporarily decreased bone resorption [37].”
BackgroundIn vitro degradation, hemolysis and MC3T3-E1 cell adhesion of biodegradable Mg–Zn alloy
Zhang, S., Li, J., Song, Y., Zhao, C., Zhang, X., Xie, C., Zhang, Y., Tao, H., He, Y., Jiang, Y., et al. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2009.03.001 · Cited by 318
Mg–Zr–Sr alloys as biodegradable implant materials
Li, Y., Wen, C., Mushahary, D., Sravanthi, R., Harishankar, N., Pande, G., & Hodgson, P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.028 · Cited by 309 · cited 1×
“Magnesium and its alloys with no treatment usually cause severe hemolysis due to their rapid degradation [46].”
BackgroundPreparation and characterization of a new biomedical magnesium–calcium alloy
Wan, Y., Xiong, G., Luo, H., He, F., Huang, Y., & Zhou, X. (2008) · Materials & Design · doi:10.1016/j.matdes.2008.04.017 · Cited by 280 · cited 1×
“Mg–Ca [51, 52], Mg–Zn [53, 54], Mg–Sr [55] and Mg–Ag [56, 57] alloys have been developed by adding single nutrient element or antibacterial element.”
BackgroundLiang, J., Srinivasan, P. B., Blawert, C., & Dietzel, W. (2009) · Corrosion Science · doi:10.1016/j.corsci.2009.06.034 · Cited by 267
Caicedo, M. S., Desai, R., McAllister, K., Reddy, A., Jacobs, J. J., & Hallab, N. J. (2009) · Journal of Orthopaedic Research · doi:10.1002/jor.20826 · Cited by 257 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundTsigkou, O., Jones, J. R., Polak, J. M., & Stevens, M. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.03.019 · Cited by 251 · cited 1×
“Biodegradable non-metal materials, such as polymers [23, 24], ceramics [25] or bioactive glasses [26], have been widely investigated as substitute of these non-degradable metallic implants.”
BackgroundAntibacterial biodegradable Mg-Ag alloys
Institute for Material Research, H.-Z. G., Tie, D., Feyerabend, F., Müller, W.-D., Schade, R., Liefeith, K., Kainer, K., & Willumeit, R. (2013) · European Cells and Materials · doi:10.22203/ecm.v025a20 · Cited by 250 · cited 1×
“Mg–Ca [51, 52], Mg–Zn [53, 54], Mg–Sr [55] and Mg–Ag [56, 57] alloys have been developed by adding single nutrient element or antibacterial element.”
BackgroundIn vitro degradation behavior and cytocompatibility of Mg–Zn–Zr alloys
Huan, Z. G., Leeflang, M. A., Zhou, J., Fratila-Apachitei, L. E., & Duszczyk, J. (2010) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-010-4111-8 · Cited by 234 · cited 1×
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc.”
A study on alkaline heat treated Mg–Ca alloy for the control of the biocorrosion rate
Gu, X. N., Zheng, W., Cheng, Y., & Zheng, Y. F. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.01.048 · Cited by 226 · cited 1×
“Apart from alkaline solution containing NaOH, three weak alkaline solutions (Na2HPO4, Na2CO3 and NaHCO3) were also applied for Mg–Ca alloy treatment [68].”
MethodCorrosion behavior of titanium nitride coated Ni–Ti shape memory surgical alloy
Starosvetsky, D., & Gotman, I. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00368-9 · Cited by 225 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundZhao, Y., Jamesh, M. I., Li, W. K., Wu, G., Wang, C., Zheng, Y., Yeung, K. W. K., & Chu, P. K. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.012 · Cited by 220 · cited 1×
“Corrosion resistance, in vitro biocompatibility and even antimicrobial properties were enhanced [123].”
BackgroundCharacteristics and cytocompatibility of biodegradable polymer film on magnesium by spin coating
Xu, L., & Yamamoto, A. (2012) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2011.12.009 · Cited by 217 · cited 2×
“(a) Surface morphologies of compact polymer coatings on magnesium substrate [101].”
BackgroundMethodGrowth and characterization of Mg(OH)2 film on magnesium alloy AZ31
Zhu, Y., Wu, G., Zhang, Y.-H., & Zhao, Q. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.02.017 · Cited by 210 · cited 2×
“(a) Surface and cross-sectional morphologies of Mg(OH)2 film by NaOH treatment for 3 h [66].”
BackgroundMethodWu, C., Fan, W., Zhou, Y., Luo, Y., Gelinsky, M., Chang, J., & Xiao, Y. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm30566f · Cited by 202
A corrosion model for bioabsorbable metallic stents
Grogan, J. A., O’Brien, B. J., Leen, S. B., & McHugh, P. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.05.032 · Cited by 200 · cited 1×
“For cardiovascular stent application, the biodegradability of the inserted stents is more meaningful because if the previous intervention treatment fails or symptoms relapse, a new stent can be implanted into the same site [20, 21].”
BackgroundFluoride treatment and in vitro corrosion behavior of an AZ31B magnesium alloy
Yan, T., Tan, L., Xiong, D., Liu, X., Zhang, B., & Yang, K. (2010) · Materials Science and Engineering: C · doi:10.1016/j.msec.2010.03.007 · Cited by 198 · cited 1×
“During the degradation process, the fluoride-treated magnesium alloy maintained better mechanical strength evaluated by three-point bending test, presenting a promise for application as biodegradable implants [71].”
BackgroundSelf-citationZreiqat, H., Valenzuela, S. M., Nissan, B. B., Roest, R., Knabe, C., Radlanski, R. J., Renz, H., & Evans, P. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.024 · Cited by 195 · cited 1×
“As bivalent ion, it takes part in apatite formation in bone matrix and is also used in a number of metabolic processes in human body [33].”
BackgroundZhang, X., Yuan, G., Mao, L., Niu, J., & Ding, W. (2012) · Materials Letters · doi:10.1016/j.matlet.2011.08.079 · Cited by 188 · cited 2×
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc. complex alloys have also been developed for better performance in mechanical properties and biocompatibility.”
Li, J., Song, Y., Zhang, S., Zhao, C., Zhang, F., Zhang, X., Cao, L., Fan, Q., & Tang, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.023 · Cited by 185 · cited 1×
“[88] found that the bone-like FHA also showed better cellular proliferation and differentiation than Mg–Zn substrate for human BMSCs (hBMSCs).”
BackgroundMetal release from stainless steel, Co–Cr–Mo–Ni–Fe and Ni–Ti alloys in vascular implants
Okazaki, Y., & Gotoh, E. (2008) · Corrosion Science · doi:10.1016/j.corsci.2008.09.002 · Cited by 181 · cited 1×
“The adverse effects including an increased risk of local inflammation may be caused by corrosion debris [17, 18] or toxic elements released into surrounding environment [19] in long-term existence of these implants.”
BackgroundA layer-by-layer approach to natural polymer-derived bioactive coatings on magnesium alloys
Kunjukunju, S., Roy, A., Ramanathan, M., Lee, B., Candiello, J. E., & Kumta, P. N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.05.013 · Cited by 172 · cited 2×
“Furthermore, surface functionalization of these coatings by chemical crosslinking and fibronectin immobilization was conducted to control the cellular activity of these multilayered films [42].”
BackgroundIshizaki, T., & Sakamoto, M. (2011) · Langmuir · doi:10.1021/la1051029 · Cited by 169 · cited 2×
“[69] only used ultrapure water to fabricate Mg(OH)2 coating on AZ31 alloy.”
BackgroundMethodSurface immobilized bisphosphonate improves stainless-steel screw fixation in rats
Tengvall, P., Skoglund, B., Askendal, A., & Aspenberg, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.049 · Cited by 158 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundOkuma, T. (2001) · Nutrition · doi:10.1016/s0899-9007(01)00551-2 · Cited by 158
Thomann, M., Krause, C., Angrisani, N., Bormann, D., Hassel, T., Windhagen, H. J., & Meyer‐Lindenberg, A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32639 · Cited by 153
Tomozawa, M., & Hiromoto, S. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.04.087 · Cited by 146 · cited 1×
“[95] formed HA coatings uniformly on pure Mg by a hydrothermal treatment using a C10H12N2O8Na2Ca (Ca-EDTA) solution.”
MethodBiofunctionalized anti-corrosive silane coatings for magnesium alloys
Liu, X., Yue, Z., Romeo, T., Weber, J., Scheuermann, T., Moulton, S. E., & Wallace, G. G. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.12.025 · Cited by 141 · cited 1×
“[103] fabricated biofunctionalized anti-corrosive silane coatings on magnesium alloys using bistriethoxysilylethane and 3-amino-propyltrimethoxysilane.”
MethodSelf-citationBioactive calcium phosphate coating formed on micro-arc oxidized magnesium by chemical deposition
Liu, G. Y., Hu, J., Ding, Z. K., & Wang, C. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.09.050 · Cited by 136 · cited 2×
“[111] formed a calcium phosphate coating on its surface by chemical method to construct MAO/Ca–P composite coatings (Fig.”
BackgroundMethodCorrosion behavior of ZrN/Zr coated biomedical AZ91 magnesium alloy
Xin, Y., Liu, C., Huo, K., Tang, G., Tian, X., & Chu, P. K.-H. (2009) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2009.02.074 · Cited by 132 · cited 1×
“Inorganic coatings have been applied to improve the corrosion resistance of magnesium and its alloys, such as DLC coatings [81, 82], TiO2 coatings [83] and ZrN/Zr bilayered coating [84].”
BackgroundMeng, E., Guan, S.-X., Wang, H. X., Wang, L. G., Zhu, S., Hu, J., Ren, C. X., Gao, J., & Feng, Y. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2010.12.073 · Cited by 131 · cited 1×
“Moreover, compared with traditional cathodic electrodeposition coating, the pulse electrodeposition coating could more effectively induce the precipitation of Mg2þ, Ca2þ and PO4 3 [91].”
BackgroundAdjustment of the ratio of Ca/P in the ceramic coating on Mg alloy by plasma electrolytic oxidation
Yao, Z., Li, L., & Jiang, Z. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2009.02.082 · Cited by 128 · cited 1×
“By simply adjusting the compositions of electrolytes, Ca–P containing coating [77, 78] and ZrO2 containing coating [79] were also successfully fabricated.”
MethodEffects of Ni and Mo on the microstructure and some other properties of Co–Cr dental alloys
Matković, T., Matković, P., & Malina, J. (2003) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2003.07.004 · Cited by 126
Kim, S., Jo, J.-H., Lee, S., Kang, M., Kim, H., Estrin, Y., Lee, J., Lee, J., & Koh, Y. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34718 · Cited by 124 · cited 2×
“Preliminary in vivo experiments showed that the biodegradation of Mg implant was significantly retarded by this HA coating [96].”
BackgroundWang, H., Guan, S., Wang, Y.-S., Liu, H., Wang, H., Wang, L., Ren, C., Zhu, S., & Chen, K. (2011) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2011.06.040 · Cited by 120
Bogdanski, D., Köller, M., Müller, D., Muhr, G., Bram, M., Buchkremer, H. P., Stöver, D., Choi, J.-S., & Epple, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00200-4 · Cited by 120 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundBiodegradable poly(lactide-co-glycolide) coatings on magnesium alloys for orthopedic applications
Ostrowski, N. J., Lee, B., Roy, A., Ramanathan, M., & Kumta, P. N. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4773-5 · Cited by 120 · cited 1×
“[102] fabricated coatings of varying thickness on magnesium alloy substrates.”
BackgroundWu, Q., Zhu, S., Wang, L., Liu, Q., Yue, G.-C., Wang, J., & Guan, S. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.12.011 · Cited by 119 · cited 1×
“For cardiovascular stent application, the biodegradability of the inserted stents is more meaningful because if the previous intervention treatment fails or symptoms relapse, a new stent can be implanted into the same site [20, 21].”
BackgroundIn vitro corrosion and biocompatibility study of phytic acid modified WE43 magnesium alloy
Ye, C. H., Zheng, Y., Wang, S. Q., Xi, T., & Li, Y. D. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.11.087 · Cited by 116 · cited 1×
“[73] used phytic acid (PA) to fabricate a conversion coating on WE43 alloy by simple immersion treatment.”
MethodLiu, C., Xin, Y., Tian, X., & Chu, P. K.-H. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.05.048 · Cited by 115
The preparation, cytocompatibility, and in vitro biodegradation study of pure β-TCP on magnesium
Geng, F., Tan, L., Jin, X., Yang, J., & Yang, K. (2009) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-008-3669-x · Cited by 113 · cited 2×
“Pure b-tricalcium phosphate (b-TCP) was also investigated by this method [94].”
BackgroundMethodWong, H. M., Zhao, Y., Tam, V., Wu, S., Chu, P. K.-H., Zheng, Y., To, M. K.-T., Leung, F. K. L., Luk, K. D. K., Cheung, K., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.052 · Cited by 111 · cited 1×
“Just because of the protection of the modified Al2O3 layer, the plasmatreated implant degraded more slowly and simultaneously stimulated bone formation in vivo in a minimal invasive way without causing post-operative complications [121].”
BackgroundBakhsheshi‐Rad, H. R., Idris, M. H., & Kadir, M. R. A. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2013.02.007 · Cited by 111
Controlling the biodegradation rate of magnesium using biomimetic apatite coating
Zhang, Y., Zhang, G., & Wei, M. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31228 · Cited by 111 · cited 1×
“The corrosion rate of the magnesium implants could be closely tailored by adjusting the apatite coating thickness [97].”
BackgroundBiodegradation kinetics of modified magnesium-based materials in cell culture medium
Carboneras, M., García-Alonso, M. C., & Escudero, M. L. (2011) · Corrosion Science · doi:10.1016/j.corsci.2011.01.014 · Cited by 110 · cited 1×
“The formed MgF2 coating on their surface slowed down the degradation rate of all the alloys, especially for cast Mg and AZ31, retarding the corrosion process in cell culture medium for at least a week [70].”
BackgroundLu, P., Cao, L., Liu, Y., Xu, X., & Wu, X. (2011) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31744 · Cited by 108 · cited 1×
“Moreover, the MAO/PLLA composite coating endowed magnesium substrate with good hemocompatibility [110].”
BackgroundIn vitro degradation of AZ31 magnesium alloy coated with nano TiO2 film by sol–gel method
Hu, J., Zhang, C., Cui, B., Bai, K., Guan, S., Wang, L., & Zhu, S. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.03.148 · Cited by 107
In vitro mechanical and corrosion properties of biodegradable Mg-Ag alloys
Tie, D., Feyerabend, F., Hort, N., Höche, D., Kainer, K. U., Willumeit‐Römer, R., & Müeller, W. D. (2013) · Materials and Corrosion · doi:10.1002/maco.201206903 · Cited by 102 · cited 1×
“Mg–Ca [51, 52], Mg–Zn [53, 54], Mg–Sr [55] and Mg–Ag [56, 57] alloys have been developed by adding single nutrient element or antibacterial element.”
BackgroundWang, Y., Wei, M., & Gao, J. (2008) · Materials Science and Engineering C · doi:10.1016/j.msec.2008.09.051 · Cited by 101 · cited 12×
“(b) Surface morphologies of DCPD [92], b-TCP [94]”
BackgroundInfluentialIshizaki, T., Okido, M., Masuda, Y., Saito, N., & Sakamoto, M. (2011) · Langmuir · doi:10.1021/la200122x · Cited by 101 · cited 1×
“[107] used vapor phase method to fabricate alkanoic and phosphonic acid-derived self-assembled monolayers on magnesium alloy.”
Methodvan Steenberghe, D., Mars, G. D., Quirynen, M., Jacobs, R., & Naert, I. (2000) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2000.011003202.x · Cited by 100
Coen, N., Kadhim, M., Wright, E. G., Case, C. P., & Mothersill, C. E. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6600758 · Cited by 99 · cited 1×
“The adverse effects including an increased risk of local inflammation may be caused by corrosion debris [17, 18] or toxic elements released into surrounding environment [19] in long-term existence of these implants.”
BackgroundElectrochemical deposition of conducting polymer coatings on magnesium surfaces in ionic liquid
Luo, X., & Cui, X. T. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.09.006 · Cited by 98 · cited 1×
“Moreover, the PEDOT coatings could load the anti-inflammatory drug dexamethasone during the electrodeposition, which could be subsequently released upon electric stimulation [105].”
BackgroundLin, H., & Bumgardner, J. D. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.016 · Cited by 93 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundCorrosion protection of DLC coatings on magnesium alloy
Choi, J., Nakao, S., Kim, J., IKEYAMA, M., & Kato, T. (2007) · Diamond and Related Materials · doi:10.1016/j.diamond.2006.11.088 · Cited by 92 · cited 1×
“Inorganic coatings have been applied to improve the corrosion resistance of magnesium and its alloys, such as DLC coatings [81, 82], TiO2 coatings [83] and ZrN/Zr bilayered coating [84].”
Evaluation of the skin sensitizing potential of biodegradable magnesium alloys
Witte, F., Abeln, I.-D., Switzer, E., Kaese, V., Meyer‐Lindenberg, A., & Windhagen, H. J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31713 · Cited by 92 · cited 1×
“However, the previous report shows that magnesium alloys, such as AZ31, AZ91, WE43 and LAE442, will not cause allergenic reactions in an epicutaneous patch test in accordance with ISO standard [36].”
ResultSynthesis and characterization of Mg‐Ca‐Sr alloys for biodegradable orthopedic implant applications
Berglund, I. S., Brar, H. S., Dolgova, N. V., Acharya, A. P., Keselowsky, B. G., Sarntinoranont, M., & Manuel, M. V. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32721 · Cited by 92
Corrosion behaviors in physiological solution of cerium conversion coatings on AZ31 magnesium alloy
Cui, X., Yang, Y., Liu, E., Jin, G. D., Zhong, J., & Li, Q. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.04.141 · Cited by 91 · cited 1×
“[74] investigated the corrosion behavior of cerium conversion coating on AZ31 magnesium alloy in physiological solution.”
BackgroundLin, J.-K., Uan, J.-Y., Wu, C.-P., & Huang, H. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm03764h · Cited by 89
Corrosion resistance improvement of magnesium alloy using nitrogen plasma ion implantation
Tian, X. B., Wei, C. B., Yang, S. Q., Fu, R. K. Y., & Chu, P. K.-H. (2005) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.10.117 · Cited by 86 · cited 1×
“[113] conducted nitrogen plasma ion implantation on AZ31B alloy.”
MethodIskandar, M. E., Aslani, A., & Liu, H. H. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34530 · Cited by 83 · cited 1×
“Apart from these commonly used methods, cold spray process [99] and transonic particle acceleration process [100] have also been used to fabricated Ca–P-based coatings on magnesium and its alloys.”
MethodInfluence of interlayers on corrosion resistance of diamond-like carbon coating on magnesium alloy
Wu, G., Сун, Л., Dai, W., Song, L., & Wang, A. (2009) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2009.12.009 · Cited by 82 · cited 1×
“Inorganic coatings have been applied to improve the corrosion resistance of magnesium and its alloys, such as DLC coatings [81, 82], TiO2 coatings [83] and ZrN/Zr bilayered coating [84].”
BackgroundEffects of tantalum ion implantation on the corrosion behavior of AZ31 magnesium alloys
Wang, X., Zeng, X., Wu, G., Yao, S., & Lai, Y. (2006) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2006.07.074 · Cited by 74 · cited 1×
“[119] found that Ta ion implantation could also improve the corrosion resistance of AZ31 alloy.”
BackgroundWu, G., Xu, R., Feng, K., Wu, S., Wu, Z., Sun, G., Zheng, G., Li, G., & Chu, P. K.-H. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.04.112 · Cited by 71 · cited 1×
“in SBF of Al-PIII-treated pure Mg [117].”
Noorakma, A. W., Zuhailawati, H., Aishvarya, V., & Dhindaw, B. (2013) · Journal of materials engineering and performance (Print) · doi:10.1007/s11665-013-0589-9 · Cited by 70
Levy, G. K., & Aghion, E. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.01.009 · Cited by 68 · cited 1×
“[75] developed a diffusion coating of Nd on Mg-1.”
BackgroundVermes, C., Glant, T., Hallab, N., Fritz, E. A., Roebuck, K., & Jacobs, J. (2001) · Journal of Arthroplasty · doi:10.1054/arth.2001.28719 · Cited by 68 · cited 1×
“The adverse effects including an increased risk of local inflammation may be caused by corrosion debris [17, 18] or toxic elements released into surrounding environment [19] in long-term existence of these implants.”
BackgroundZhao, Y., Wu, G., Lu, Q., Wu, J. Y., Xu, R., Yeung, K., & Chu, P. K.-H. (2012) · Thin Solid Films · doi:10.1016/j.tsf.2012.05.046 · Cited by 66 · cited 1×
“tion curves of Ti and Ti–O dual ion implantation treated WE43 alloy [122].”
Surface-dimpled commercially pure titanium implant and bone ingrowth
Li, J., Liao, H., Fartash, B., Hermansson, L., & Johnsson, T. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00185-8 · Cited by 65 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundYang, X., Li, M., Lin, X. Y., Tan, L., Lan, G., Li, L., Yin, Q., Xia, H., Zhang, Y., & Yang, K. (2013) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2013.01.052 · Cited by 64
Anticorrosion and cytocompatibility behavior of MAO/PLLA modified magnesium alloy WE42
Guo, M., Cao, L., Lu, P., Liu, Y., & Xu, X. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4354-z · Cited by 64 · cited 2×
“WE42-MAO, WE42-MAO/PLLA and corrosion mass loss of WE42, WE42-MAO/PLLA [109].”
BackgroundRapid degradation of biomedical magnesium induced by zinc ion implantation
Wu, G., Li, G., Feng, K., Wu, S., Zhao, Y., & Chu, P. K.-H. (2010) · Materials Letters · doi:10.1016/j.matlet.2010.11.059 · Cited by 62 · cited 1×
“(b) XPS depth profile, polarization curve in SBF and corrosion in SBF for 18 h of Zn-PIII-treated pure Mg [116].”
BackgroundControllable degradation of biomedical magnesium by chromium and oxygen dual ion implantation
Xu, R., Wu, G., Yang, X., Hu, T., Lu, Q., & Chu, P. K.-H. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.04.043 · Cited by 57 · cited 1×
“The formed layer could successfully retarded the surface degradation of pure magnesium [124].”
BackgroundVaritimidis, S. E., Dimitroulias, A. P., Karachalios, T. S., Dailiana, Z. H., & Malizos, Κ. Ν. (2009) · Acta Orthopaedica · doi:10.1080/17453670902804877 · Cited by 55
Degradable magnesium‐based implant materials with anti‐inflammatory activity
Peng, Q., Li, K., Han, Z., Wang, E., Xu, Z., Liu, R., & Tian, Y. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34494 · Cited by 53 · cited 2×
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc. complex alloys have also been developed for better performance in mechanical properties and biocompatibility.”
Zhang, Y., Li, L., Shi, Z., Wang, J., & Li, Z. (2012) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-012-0962-7 · Cited by 50 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundCorrosion properties of oxygen plasma immersion ion implantation treated magnesium
Wan, G., Maitz, M. F., Sun, H. L., Li, P. P., & Huang, N. (2007) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2006.02.088 · Cited by 47 · cited 1×
“[112] used oxygen plasma immersion ion implantation to control the degradation rate of magnesium substrate.”
MethodCalcium–phosphate coatings obtained biomimetically on magnesium substrates under low magnetic field
Yanovska, A., Кузнецов, В. Н., Stanislavov, A. S., Danilchenko, S. N., & Sukhodub, L. F. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.05.052 · Cited by 47 · cited 1×
“3c) and the magnetic field influenced the particle morphology and crystal texture of the precipitates [98].”
BackgroundFormation and electrochemical behavior of Al and O plasma-implanted biodegradable Mg-Y-RE alloy
Zhao, Y., Wu, G., Pan, H., Yeung, K., & Chu, P. K.-H. (2011) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2011.11.028 · Cited by 46 · cited 2×
“The modified layer improved the corrosion resistance of the substrate and localized corrosion became the dominant corrosion mechanism instead of general corrosion [120].”
BackgroundSanchez, A. G., Ballarre, J., Orellano, J. C., Duffó, G. S., & Ceré, S. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4770-8 · Cited by 44 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundYun, Y., Turitto, V. T., Daigle, K., Kovacs, P., Davidson, J. A., & Slack, S. M. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<77::aid-jbm9>3.0.co;2-m · Cited by 43 · cited 1×
“The early metallic materials used as biomedical implants consist of stainless steel [1, 2], Co–Cr-based alloys [3–6], titanium-based alloys [6–12], zirconium-based alloys [13, 14] and tantalum-based alloys [15, 16].”
BackgroundSebaa, M. A., Dhillon, S., & Liu, H. H. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4796-y · Cited by 39 · cited 2×
“(c) Surface morphologies of PEDOT conductive coatings fabricated on magnesium with different processes [104].”
BackgroundMethodAssociation of macrovascular complications of type 2 diabetes mellitus with serum magnesium levels
Agrawal, P., Arora, S., Singh, B. M., Manamalli, A., & Dolia, P. B. (2010) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2010.12.003 · Cited by 38 · cited 1×
“The inefficient of magnesium excretion will result in an increase of serum magnesium level, which may cause many dangerous complications [43].”
BackgroundBioactive Ca–P coating with self-sealing structure on pure magnesium
Gan, J., Tan, L., Yang, K., Hu, Z., Zhang, Q., Fan, X., Li, Y., & Li, W. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-4850-4 · Cited by 38 · cited 1×
“By simply adjusting the compositions of electrolytes, Ca–P containing coating [77, 78] and ZrO2 containing coating [79] were also successfully fabricated.”
MethodGrubač, Z., Metikoš‐Huković, M., Babić, R., Rončević, I. Š., Petravić, M., & Peter, R. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.01.028 · Cited by 35 · cited 1×
“[106] fabricated alkylphosphonate self-assembled films on AZ91D alloy.”
BackgroundComplement-mediated leukocyte adhesion on poly(etherurethane ureas) under shear stressin vitro
Kao, W. J., Sapatnekar, S., Hiltner, A., & Anderson, J. M. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199609)32:1<99::aid-jbm12>3.0.co;2-d · Cited by 31
Water plasma implantation/oxidation of magnesium alloys for corrosion resistance
Tian, X. B., Wei, C. B., Yang, S. Q., Fu, R. K. Y., & Chu, P. K.-H. (2005) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2005.08.035 · Cited by 30 · cited 1×
“[114] also applied water plasma ion implantation and oxidation for magnesium alloys to improve their corrosion resistance.”
MethodXu, R., Yang, X., Zhang, X., Wang, M., Li, P., Zhao, Y., Wu, G., & Chu, P. K.-H. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.09.060 · Cited by 29 · cited 4×
“After SBF incubation, some new apatite formed on the calcified coating surface.”
BackgroundInfluentialLalk, M., Reifenrath, J., Rittershaus, D., Bormann, D., & Meyer‐Lindenberg, A. (2010) · Materialwissenschaft und Werkstofftechnik · doi:10.1002/mawe.201000704 · Cited by 22
Xu, R., Wu, G., Yang, X., Zhang, X., Wu, Z., Sun, G., Li, G., & Chu, P. K.-H. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.05.036 · Cited by 22 · cited 1×
“(c) XPS depth profile and polarization curves in SBF and Na2SO4 of Cr–O dual ion implantation treated pure Mg [125].”
BackgroundIn vitro response of chondrocytes to a biodegradable Mg–Nd–Zn–Zr alloy
Liao, Y., Ouyang, Y., Niu, J., Zhang, J., Wang, Y., Zhaojing, Z., Yuan, G., He, Y., & Jiang, Y. (2012) · Materials Letters · doi:10.1016/j.matlet.2012.05.111 · Cited by 8 · cited 2×
“Mg–Zn–Zr [58], Mg–Zn–Ag [59], Mg–Ca–Sr [60], Mg–Zn–Mn [61] and Mg–Nb–Zn–Zr [62, 63], etc. complex alloys have also been developed for better performance in mechanical properties and biocompatibility.”
Research works printed but not linked: 13
- 1976, The Bone & Joint Journal, 58, 107
- 2008, 12, 63
- 2013, MATER CORROSION, 64, 1
- 2012, Journal of biomedical materials research. Part A, 101, 1898
- 2012, 66, 209
- 2012, 83, 206
- 2013, Journal of materials science. Materials in medicine, 24, 889
- 2010, 6, 1743, 10.1016/j.actbio.2009.12.009 · DOI · Paper page
- 2013, Journal of biomedical materials research. Part A, 101, 2340
- 2013, Journal of materials science. Materials in medicine, 24, 85
- 2011, J BIOMED MATER RES PART B APPL BIOMATER, 96, 101
- 2011, 65, 661
- 2011, 65, 2171
Cited by
Research and Development in Magnesium Alloys for Industrial and Biomedical Applications: A Review
Vignesh, R. V., Ramasamy, P., Kovukkal, M. D., & Myilsamy, G. (2019) · Metals and Materials International · doi:10.1007/s12540-019-00346-8 · Cited by 310
Biodegradable metallic bone implants
Shuai, C., Li, S., Peng, S., Feng, P., Lai, Y., & Gao, C. (2019) · Materials Chemistry Frontiers · doi:10.1039/c8qm00507a · Cited by 275
Applications of Metals for Bone Regeneration
Glenske, K., Donkiewicz, P., Köwitsch, A., Milosevic-Oljaca, N., Rider, P., Rofall, S., Franke, J., Jung, O., Smeets, R., Schnettler, R., et al. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19030826 · Cited by 247
Magnesium based implants for functional bone tissue regeneration – A review
Uppal, G., Thakur, A., Chauhan, A., & Bala, S. (2022) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.08.017 · Cited by 209
Surface treatments for controlling corrosion rate of biodegradable Mg and Mg-based alloy implants
Uddin, M. S., Hall, C., & Murphy, P. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/5/053501 · Cited by 189
“Furthermore, the detailed description of different types of ion implantation can be found in a comprehensive review performed by Tian and Liu [69].”
BackgroundInfluential
Metadata
- Authors
- Tian, P., & Liu, X.
- Affiliations
- Chinese Academy of Sciences (CN)
- Corresponding author
- Liu, X.
- ORCID
- Tian, P.
- Venue
- Regenerative Biomaterials
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-11-27
- Volume
- 2
- Issue
- 2
- Pages
- 135-151
- ISSN
- 2056-3418 (ISSN-L)
- 2056-3426
- PMC
- PMC4669019
- OpenAlex
- W1971085544
- Semantic Scholar
- 7eb87072668a371340f5c86266b38187c0e8fcb8
- Cited by
- 218
- References
- 124
- Citations by year
- 2026: 23 · 2025: 23 · 2024: 22 · 2023: 15 · 2022: 23 · 2021: 28 · 2020: 26 · 2019: 22 · 2018: 19 · 2017: 6 · 2016: 8 · 2015: 3
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Regenerative Biomaterials (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (973 Program, 2012CB933600, 81271704)
- National Key Research and Development Program of China (973 Program, 2012CB933600, 2012CB933600)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- magnesium alloys, biodegradable implants, surface modification, corrosion resistance, hemocompatibility, cytocompatibility, implant-tissue interface, temporary implants, orthopedic implants, cardiovascular stents, magnesium ion release, biodegradation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.