The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Pulmonary Toxicity of Single-Wall Carbon Nanotubes in Mice 7 and 90 Days After Intratracheal Instillation
Abstract
Nanomaterials are part of an industrial revolution to develop lightweight but strong materials for a variety of purposes. Single-wall carbon nanotubes are an important member of this class of materials. They structurally resemble rolled-up graphite sheets, usually with one end capped; individually they are about 1 nm in diameter and several microns long, but they often pack tightly together to form rods or ropes of microscopic sizes. Carbon nanotubes possess unique electrical, mechanical, and thermal properties and have many potential applications in the electronics, computer, and aerospace industries. Unprocessed nanotubes are very light and could become airborne and potentially reach the lungs. Because the toxicity of nanotubes in the lung is not known, their pulmonary toxicity was investigated. The three products studied were made by different methods and contained different types and amounts of residual catalytic metals. Mice were intratracheally instilled with 0, 0.1, or 0.5 mg of carbon nanotubes, a carbon black negative control, or a quartz positive control and euthanized 7 d or 90 d after the single treatment for histopathological study of the lungs. All nanotube products induced dose-dependent epithelioid granulomas and, in some cases, interstitial inflammation in the animals of the 7-d groups. These lesions persisted and were more pronounced in the 90-d groups; the lungs of some animals also revealed peribronchial inflammation and necrosis that had extended into the alveolar septa. The lungs of mice treated with carbon black were normal, whereas those treated with high-dose quartz revealed mild to moderate inflammation. These results show that, for the test conditions described here and on an equal-weight basis, if carbon nanotubes reach the lungs, they are much more toxic than carbon black and can be more toxic than quartz, which is considered a serious occupational health hazard in chronic inhalation exposures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparative Pulmonary Toxicity Assessment of Single-wall Carbon Nanotubes in Rats
Warheit, D. B. (2003) · Toxicological Sciences · doi:10.1093/toxsci/kfg228 · Cited by 1,515
Large-scale purification of single-wall carbon nanotubes: process, product, and characterization
Rinzler, A. G., Liu, J., Dai, H., Nikolaev, P., Huffman, C. B., Rodríguez-Macías, F. J., Boul, P. J., Lu, A. H., Heymann, D., Colbert, D. T., et al. (1998) · Applied Physics A: Materials Science & Processing · doi:10.1007/s003390050734 · Cited by 1,340
Documentation of the Threshold Limit Values and Biological Exposure Indices
Acgih (2001) · Medical Entomology and Zoology · Cited by 845
Bates, D. V., Fish, B., Hatch, T. F., Mercer, T. T., & Morrow, P. E. (1966) · PubMed · Cited by 771
Maynard, A. D., Baron, P. A., Foley, M., Shvedova, A. A., Kisin, E. R., & Castranova, V. (2004) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287390490253688 · Cited by 763
Bronikowski, M. J., Willis, P. A., Colbert, D. T., Smith, K. A., & Smalley, R. E. (2001) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.1380721 · Cited by 671
Driscoll, K. E. (2000) · Toxicological Sciences · doi:10.1093/toxsci/55.1.24 · Cited by 578 · cited 2×
“For the present study, we used intratracheal instillation, an accepted route of exposure commonly used to screen dusts for potential pulmonary toxicity (Leong et al., 1998; Driscoll et al., 2000).”
BackgroundMethodNanometre-size tubes of carbon
Ajayan, P. M., & Ebbesen, T. W. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/10/001 · Cited by 496
Comparative Biology of the Normal Lung
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-01154-4 · Cited by 355
Deposition and Retention Models for Internal Dosimetry of the Human Respiratory Tract
(1966) · Health Physics · doi:10.1097/00004032-196602000-00005 · Cited by 312
Cited by
Items 201–219 of 219
Pulmonary fibrotic response to aspiration of multi-walled carbon nanotubes
Mercer, R. R., Hubbs, A. F., Scabilloni, J. F., Wang, L., Battelli, L. A., Friend, S., Castranova, V., & Porter, D. W. (2011) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-8-21 · Cited by 259
Aschberger, K., Johnston, H. J., Stone, V., Aitken, R. J., Hankin, S. M., Peters, S. A. K., Tran, C. L., & Christensen, F. M. (2010) · Critical Reviews in Toxicology · doi:10.3109/10408444.2010.506638 · Cited by 255
Nanoparticle-induced pulmonary toxicity
Li, J. J., Muralikrishnan, S., Ng, C.-T., Yung, L.-Y. L., & Bay, B.-H. (2010) · Experimental Biology and Medicine · doi:10.1258/ebm.2010.010021 · Cited by 254
Bello, D., Wardle, B. L., Yamamoto, N., Guzman deVilloria, R., Garcia, E. J., Hart, A. J., Ahn, K., Ellenbecker, M. J., & Hallock, M. (2009) · Journal of Nanoparticle Research · doi:10.1007/s11051-008-9499-4 · Cited by 252
Perturbational profiling of nanomaterial biologic activity
Shaw, S. Y., Westly, E. C., Pittet, M. J., Subramanian, A., Schreiber, S. L., & Weissleder, R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0802878105 · Cited by 248
Sanchez, V. C., Pietruska, J. R., Miselis, N. R., Hurt, R. H., & Kane, A. B. (2009) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.41 · Cited by 186
Bioavailability of Nickel in Single‐Wall Carbon Nanotubes
Liu, X., Gurel, V., Morris, D., Murray, D. W., Zhitkovich, A., Kane, A. B., & Hurt, R. H. (2007) · Advanced Materials · doi:10.1002/adma.200602696 · Cited by 169
Inhalation Exposure to Carbon Nanotubes (CNT) and Carbon Nanofibers (CNF): Methodology and Dosimetry
Oberdörster, G., Castranova, V., Asgharian, B., & Sayre, P. (2015) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2015.1051611 · Cited by 150
Hazards and Risks of Engineered Nanoparticles for the Environment and Human Health
Hristozov, D., & Malsch, I. (2009) · Sustainability · doi:10.3390/su1041161 · Cited by 149
Targeted removal of bioavailable metal as a detoxification strategy for carbon nanotubes
Liu, X., Guo, L., Morris, D., Kane, A. B., & Hurt, R. H. (2008) · Carbon · doi:10.1016/j.carbon.2007.12.018 · Cited by 135
Toxicity of Carbon Nanotubes as Anti-Tumor Drug Carriers
Yan, H., Xue, Z., Xie, J., Dong, Y., Ma, Z., Sun, X., Kebebe Borga, D., Liu, Z., & Li, J. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s220087 · Cited by 113
What is currently known about the health risks related to carbon nanotube exposures?
Warheit, D. B. (2006) · Carbon · doi:10.1016/j.carbon.2005.10.013 · Cited by 112
Kuempel, E. D., Jaurand, M.-C., Møller, P., Morimoto, Y., Kobayashi, N., Pinkerton, K. E., Sargent, L. M., Vermeulen, R. C. H., Fubini, B., & Kane, A. B. (2017) · Critical Reviews in Toxicology · doi:10.1080/10408444.2016.1206061 · Cited by 89
Oxidatively damaged DNA in animals exposed to particles
Møller, P., Danielsen, P. H., Jantzen, K., Roursgaard, M., & Loft, S. (2013) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.756456 · Cited by 73
Lynch, I. (2007) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/j.physa.2006.06.008 · Cited by 50
Potential Uses of Carbon Nanotubes in The Medical Field: How Worried Should Patients Be?
Boczkowski, J., & Lanone, S. (2007) · Nanomedicine · doi:10.2217/17435889.2.4.407 · Cited by 39
A feasible way to use carbon nanotubes to deliver drug molecules: transdermal application
Ilbasmis – Tamer, S., & Degim, I. T. (2012) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2012.696607 · Cited by 26
The Significance and Insignificance of Carbon Nanotube-Induced Inflammation
Boyles, M., Stoehr, L., Schlinkert, P., Himly, M., & Duschl, A. (2014) · Fibers · doi:10.3390/fib2010045 · Cited by 22
“[44] was considerably greater than the highest dose administered by Kobayashi et al.”
BackgroundMethodInfluentialFortini, R., Meyer-Plath, A., Kehren, D., Gernert, U., Jácome, L. A., & Sturm, H. (2020) · Fibers · doi:10.3390/fib8050031 · Cited by 18
“Early studies revealed that some types of CNTs may indeed cause strong inflammation and necrosis in the lungs of mice exposed to different amounts of CNTs [11,12].”
Background
Metadata
- Authors
- Lam, C.-W.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-12-22
- Volume
- 77
- Issue
- 1
- Pages
- 126-134
- ISSN
- 1096-0929 (ISSN-L)
- OpenAlex
- W2151609134
- Cited by
- 1,991
- References
- 24
- FWCI
- 45.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.