Effect of extracellular matrix topology on cell structure, function, and physiological responsiveness: hepatocytes cultured in a sandwich configuration
The DOI matches its Crossref record.
Abstract
Extracellular matrix (ECM) geometry is an important modulator of cell polarity and function. For example, 3‐dimensional matrices often more effectively induce differentiated cell function than traditional 2‐dimensional substrates. The effect of ECM topology can be investigated in a controlled fashion using a technique whereby cells cultured on a single surface are overlaid with a second layer of ECM, thereby creating a ”sandwich” configuration. Confluent monolayers of epithelial or endothelial cells overlaid in this fashion often reorganize into structures that are reminiscent of their native tissue. In the case of hepatocytes, the overlay causes a dramatic reorganization of the cytoskeleton, adoption of in vivo‐like morphology and polarity, and expression of a wide array of liver‐specific functions. In this short review, we use the sandwiched hepato‐ cyte culture system to illustrate the effect of ECM geometry on cellular function. Pertinent studies are summarized in the context of defining the parallels, strengths, and limitations of this culture system as an in vitro model to study the physiology and morphogenesis of liver tissue. We also explore some of its potential uses as a model to study liver pharmacology and toxicology, and for the development of liver preservation techniques and liver‐assist devices.—Berthiaume, F., Moghe, P. V., Toner, M., Yarmush, M. L. Effect of extracellular matrix topology on cell structure, function, and physiological responsiveness: hepatocytes cultured in a sandwich configuration. FASEB J . 10, 1471—1484 (1996)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
2D and 3D Cell Cultures - a Comparison of Different Types of Cancer Cell Cultures
Kapałczyńska, M., Kolenda, T., Przybyła, W., Zajączkowska, M., Teresiak, A., Filas, V., Ibbs, M., Bliźniak, R., Łuczewski, Ł., & Lamperska, K. (2016) · Archives of Medical Science · doi:10.5114/aoms.2016.63743 · Cited by 1,499
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
“3); however, when isolated and cultured on tissue culture plastic, they adhere and spread, losing many of their characteristic features (73).”
BackgroundResultSelf-citationMicroengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Self-citationLee, P. J., Hung, P. J., & Lee, L. P. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21360 · Cited by 509
Lu, H. H., Cooper, J. A., Manuel, S., Freeman, J. W., Attawia, M. A., Ko, F. K., & Laurencin, C. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.050 · Cited by 380
The application of nanofibrous scaffolds in neural tissue engineering
Cao, H., Liu, T., & Chew, S. Y. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.07.009 · Cited by 350
Multi-cell type human liver microtissues for hepatotoxicity testing
Messner, S., Agarkova, I., Moritz, W., & Kelm, J. M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0968-2 · Cited by 319
“However, such hepatocyte cultures are phenotypically and functionally not very stable over time which impedes their use for long-term toxicity testing (Berthiaume et al. 1996).”
Review Paper: A Review of the Cellular Response on Electrospun Nanofibers for Tissue Engineering
Nisbet, D. R., Forsythe, J. S., Shen, W., Finkelstein, D. I., & Horne, M. K. (2009) · Journal of Biomaterials Applications · doi:10.1177/0885328208099086 · Cited by 299
Microscale tissue engineering using gravity-enforced cell assembly
Kelm, J. M., & Fussenegger, M. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.02.002 · Cited by 297
Design of artificial extracellular matrices for tissue engineering
Kim, B.-S., Park, I.-K., Hoshiba, T., Jiang, H.-L., Choi, Y.-J., Akaike, T., & Cho, C.-S. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.10.001 · Cited by 296
Abrams, G. A., Goodman, S. L., Nealey, P. F., Franco, M., & Murphy, C. J. (2000) · Cell and Tissue Research · doi:10.1007/s004419900074 · Cited by 292
Revzin, A., Tompkins, R. G., & Toner, M. (2003) · Langmuir · doi:10.1021/la035129b · Cited by 258
Self-citationA microfluidically perfused three dimensional human liver model
Rennert, K., Steinborn, S., Gröger, M., Ungerböck, B., Jank, A.-M., Ehgartner, J., Nietzsche, S., Dinger, J., Kiehntopf, M., Funke, H., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.043 · Cited by 255
Development of a 3D cell printed construct considering angiogenesis for liver tissue engineering
Lee, J. W., Choi, Y.-J., Yong, W.-J., Pati, F., Shim, J.-H., Kang, K. S., Kang, I.-H., Park, J., & Cho, D.-W. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/015007 · Cited by 254
Treyer, A., & Müsch, A. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120009 · Cited by 252
“The role of ECM signaling in the hepatocyte differentiation process has also been appreciated in the longstanding efforts toward the development of a bioartificial liver that have led to constant improvements in culture conditions to maintain highly differentiated and polarized hepatocytes in either monolayers or sphe…”
Lauschke, V. M., Hendriks, D. F. G., Bell, C. C., Andersson, T. B., & Ingelman-Sundberg, M. (2016) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00150 · Cited by 241
Lee, J. S., Shin, J., Park, H.-M., Kim, Y.-G., Kim, B.-G., Oh, J.-W., & Cho, S.-W. (2014) · Biomacromolecules · doi:10.1021/bm4015039 · Cited by 236
Bokhari, M., Carnachan, R. J., Cameron, N. R., & Przyborski, S. A. (2007) · Journal of Anatomy · doi:10.1111/j.1469-7580.2007.00778.x · Cited by 227
“It is well known that culturing hepatocytes in conventional monolayer formats leads to cells adopting flat morphologies, with rare and short-lived bile canalicular-like structures (Awata et al. 1998; Berthiaume et al. 1996).”
BackgroundMicrofluidic organ-on-a-chip models of human liver tissue
Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.041 · Cited by 204
Biology on a Chip: Microfabrication for Studying the Behavior of Cultured Cells
Li, N., Tourovskaia, A., & Folch, A. (2003) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v31.i56.20 · Cited by 186
Galactose-carrying polymers as extracellular matrices for liver tissue engineering
Cho, C. S., Seo, S. J., Park, I. K., Kim, S. H., Kim, T. H., Hoshiba, T., Harada, I., & Akaike, T. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.06.008 · Cited by 174
Nie, C., Ma, L., Xia, Y., He, C., Deng, J., Wang, L., Cheng, C., Sun, S., & Zhao, C. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.11.005 · Cited by 168
In Vitro Models for Non-Alcoholic Fatty Liver Disease: Emerging Platforms and Their Applications
Ramos, M. J., Bandiera, L., Menolascina, F., & Fallowfield, J. A. (2022) · iScience · doi:10.1016/j.isci.2021.103549 · Cited by 127
Cuvellier, M., Ezan, F., Oliveira, H., Rose, S., Fricain, J.-C., Langouët, S., Legagneux, V., & Baffet, G. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120611 · Cited by 126
Challenges and Opportunities in the Design of Liver-on-Chip Microdevices
Ehrlich, A., Duche, D., Ouedraogo, G., & Nahmias, Y. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052305 · Cited by 125
In Vitro and In Vivo Models of Non-Alcoholic Fatty Liver Disease: A Critical Appraisal
Soret, P.-A., Magusto, J., Housset, C., & Gautheron, J. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm10010036 · Cited by 121
“Moreover, the metabolic activities (e.g., cytochrome P activity) of PHHs were reduced gradually across culture time in line with what has been observed in the liver of NAFLD patients [59].”
BackgroundInfluentialLong-Term Culture and Coculture of Primary Rat and Human Hepatocytes
Shulman, M., & Nahmias, Y. (2012) · Methods in Molecular Biology · doi:10.1007/978-1-62703-125-7_17 · Cited by 117
“While hepatocytes entrapped in collagen matrix show a cuboidal morphology (21), spheroids are round, and form closely associated aggregates, which are not found in the mature liver.”
BackgroundBrown, J. H., Das, P., DiVito, M. D., Ivancic, D., Tan, L. P., & Wertheim, J. A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.02.009 · Cited by 114
3D Cultivation Techniques for Primary Human Hepatocytes
Bachmann, A., Moll, M., Gottwald, E., Nies, C., Zantl, R., Wagner, H., Burkhardt, B., Sánchez, J., Ladurner, R., Thasler, W., et al. (2015) · Microarrays · doi:10.3390/microarrays4010064 · Cited by 59
“The interaction of hepatocytes with a three-dimensional environment preserves their function as well as the expression of specific transporters, cell-cell communication via tight and gap junctions, and the formation of bile canaliculi [8,35].”
BackgroundFiegel, H. C., Havers, J., Kneser, U., Smith, M. K., Moeller, T., Kluth, D., Mooney, D. J., Rogiers, X., & Kaufmann, P. M. (2004) · Tissue Engineering · doi:10.1089/107632704322791817 · Cited by 59
Deharde, D., Schneider, C., Hiller, T., Fischer, N., Kegel, V., Lübberstedt, M., Freyer, N., Hengstler, J. G., Andersson, T. B., Seehofer, D., et al. (2016) · Archives of Toxicology · doi:10.1007/s00204-016-1758-z · Cited by 65
Basement membrane properties and their recapitulation in organ-on-chip applications
Salimbeigi, G., Vrana, N. E., Ghaemmaghami, A. M., Huri, P. Y., & McGuinness, G. B. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100301 · Cited by 57
Fukuda, J., Okamura, K., Nakazawa, K., Ijima, H., Yamashita, Y., Shimada, M., Shirabe, K., Tsujita, E., Sugimachi, K., & Funatsu, K. (2003) · Cell Transplantation · doi:10.3727/000000003783985151 · Cited by 54
Lee, H.-J., Son, M. J., Ahn, J., Oh, S. J., Lee, M., Kim, A., Jeung, Y.-J., Kim, H.-G., Won, M., Lim, J. H., et al. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.09.041 · Cited by 47
Roles of Spheroid Formation of Hepatocytes in Liver Tissue Engineering
Jiang, H.-L., Kim, Y.-K., Cho, K.-H., Jang, Y.-C., Choi, Y.-J., Chung, J.-H., & Cho, C.-S. (2010) · International Journal of Stem Cells · doi:10.15283/ijsc.2010.3.2.69 · Cited by 22
“Many researches have been focused on the design of ECM topology for the spheroid formation of hepatocytes because the topology of ECM affects cell morphology and this structure resembles the tight cell-cell contact in native liver and tight junctions (8).”
BackgroundCross-species comparison of CAR-mediated procarcinogenic key events in a 3D liver microtissue model
Plummer, S., Beaumont, B., Wallace, S., Ball, G., Wright, J., McInnes, L., Currie, R., Peffer, R., & Cowie, D. (2019) · Toxicology Reports · doi:10.1016/j.toxrep.2019.09.010 · Cited by 20
Fan, J. Y., Dama, G., Liu, Y. L., Guo, W. Y., & Lin, J. T. (2023) · Molecular Biology · doi:10.1134/s0026893323040039 · Cited by 2
Metadata
- Authors
- Berthiaume, F., Moghe, P. V., Toner, M., & Yarmush, M. L.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 10
- Issue
- 13
- Pages
- 1471-1484
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W1848082114
- Cited by
- 401
- References
- 0
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.