Arterial and Venous Contributions to Near-infrared Cerebral Oximetry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Cerebral oximetry is a noninvasive bedside technology using near-infrared light to monitor cerebral oxygen saturation (Sco2) in an uncertain mixture of arteries, capillaries, and veins. The present study used frequency domain near-infrared spectroscopy to determine the ratio of arterial and venous blood monitored by cerebral oximetry during normoxia, hypoxia, and hypocapnia. Methods: Twenty anesthetized children aged < 8 yr with congenital heart disease of varying arterial oxygen saturation (Sao2) were studied during cardiac catheterization. Sco2, Sao2, and jugular bulb oxygen saturation (Sjo2) were measured by frequency domain near-infrared spectroscopy and blood oximetry at normocapnia room air, normocapnia 100% inspired O2, and hypocapnia room air. Results: Among subject conditions, Sao2 ranged from 68% to 100%, Sjo2 from 27% to 96%, and Sco2 from 29% to 92%. Sco2 was significantly related to Sao2 (y = 0. 85 x -17, r = 0.47), Sjo2 (y = 0.77 x +13, r = 0.70), and the combination (Sco2 = 0.46 Sao2 + 0.56 Sjo2 - 17, R = 0.71). The arterial and venous contribution to cerebral oximetry was 16 +/- 21% and 84 +/- 21%, respectively (where Sco2 = alpha Sao2 + beta Sjo2 with alpha and beta being arterial and venous contributions). The contribution was similar among conditions but differed significantly among subjects (range, approximately 40:60 to approximately 0:100, arterial:venous). Conclusions: Cerebral oximetry monitors an arterial/venous ratio of 16:84, similar in normoxia, hypoxia, and hypocapnia. Because of biologic variation in cerebral arterial/venous ratios, use of a fixed ratio is not a good method to validate the technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Cited by
Near-infrared spectroscopy as an index of brain and tissue oxygenation
Murkin, J. M., & Arango, M. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep299 · Cited by 877
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Davie, S. N., & Grocott, H. P. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824c00d7 · Cited by 383
Yao, F.-S. F., Tseng, C.-C. A., Ho, C.-Y. A., Levin, S. K., & Illner, P. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.007 · Cited by 351
TORTORIELLO, T. A., STAYER, S. A., MOTT, A. R., DEAN McKENZIE, E., FRASER, C. D., ANDROPOULOS, D. B., & CHANG, A. C. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01488.x · Cited by 269
Murphy, G. S., Szokol, J. W., Marymont, J. H., Greenberg, S. B., Avram, M. J., Vender, J. S., Vaughn, J., & Nisman, M. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e33bd9 · Cited by 261
Roche‐Labarbe, N., Carp, S. A., Surova, A., Patel, M., Boas, D. A., Grant, P. E., & Franceschini, M. A. (2010) · Human Brain Mapping · doi:10.1002/hbm.20868 · Cited by 236
“We worked from the assumption that: StO2 ¼ aSaO2 þ bSvO2, with a þ b ¼ 1 [Watzman et al., 2000] and a and b are constants.”
MethodNear-Infrared Spectroscopy Cerebral Oxygen Saturation Thresholds for Hypoxia–Ischemia in Piglets
Kurth, C. D., Levy, W. J., & McCann, J. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200203000-00011 · Cited by 236
“…the hemoglobin monitored by NIRS is located in the tissue circulation (venules, capillaries, and arterioles) and because cytochrome aa3 is located in neurons, oxygenation status monitoring can indicate cerebral hypoxia-ischemia (Nioka et al., 1990; Springett et al., 2001; Watzman et al., 2001).”
BackgroundSelf-citationNaulaers, G., Meyns, B., Miserez, M., Leunens, V., Van Huffel, S., Casaer, P., Weindling, M., & Devlieger, H. (2007) · Neonatology · doi:10.1159/000101063 · Cited by 218
Capillary-Oxygenation-Level-Dependent Near-Infrared Spectrometry in Frontal Lobe of Humans
Rasmussen, P., Dawson, E. A., Nybo, L., van Lieshout, J. J., Secher, N. H., & Gjedde, A. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600416 · Cited by 216
“Positron emission tomography reveals an increase in the arterial blood volume fraction when CBF increases (Ito et al, 2005) while NIRS, indirectly, shows that the arterial fraction decreases (Watzman et al, 2000).”
BackgroundMethodResultInfluentialTabbutt, S., Ramamoorthy, C., Montenegro, L. M., Durning, S. M., Kurth, C. D., Steven, J. M., Godinez, R. I., Spray, T. L., Wernovsky, G., & Nicolson, S. C. (2001) · Circulation · doi:10.1161/hc37t1.094818 · Cited by 208
Self-citationMarino, B. S., Tabbutt, S., MacLaren, G., Hazinski, M. F., Adatia, I., Atkins, D. L., Checchia, P. A., DeCaen, A., Fink, E. L., Hoffman, G. M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000524 · Cited by 203
Cerebral Oximetry for Cardiac and Vascular Surgery
Edmonds, H. L., Ganzel, B. L., & Austin, E. H. (2004) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/108925320400800208 · Cited by 203
Alderliesten, T., Dix, L., Baerts, W., Caicedo, A., van Huffel, S., Naulaers, G., Groenendaal, F., van Bel, F., & Lemmers, P. (2016) · Pediatric Research · doi:10.1038/pr.2015.186 · Cited by 199
Cerebral Oxygen Metabolism in Neonates with Congenital Heart Disease Quantified by MRI and Optics
Jain, V., Buckley, E. M., Licht, D. J., Lynch, J. M., Schwab, P. J., Naim, M. Y., Lavin, N. A., Nicolson, S. C., Montenegro, L. M., Yodh, A. G., et al. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.214 · Cited by 198
Self-citationDurduran, T., Zhou, C., Buckley, E. M., Kim, M. N., Yu, G., Choe, R., Gaynor, J. W., Spray, T. L., Durning, S. M., Mason, S. E., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3425884 · Cited by 196
Self-citationYu, Y., Zhang, K., Zhang, L., Zong, H., Meng, L., & Han, R. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010947.pub2 · Cited by 179
Assessment of Infant Brain Development With Frequency-Domain Near-Infrared Spectroscopy
Franceschini, M. A., Thaker, S., Themelis, G., Krishnamoorthy, K. K., Bortfeld, H., Diamond, S. G., Boas, D. A., Arvin, K., & Grant, P. E. (2007) · Pediatric Research · doi:10.1203/pdr.0b013e318045be99 · Cited by 177
“with a b 1 and b constant with age (26).”
BackgroundCerebral oxygen saturation before congenital heart surgery
Kurth, C. D., Steven, J. L., Montenegro, L. M., Watzman, H. M., Gaynor, J. W., Spray, T. L., & Nicolson, S. C. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02632-7 · Cited by 173
“Cerebral oximetry views a “weighted average” of the tissue circulation, with approximately 85% of the signal originating from venules [11].”
BackgroundSelf-citationThavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165
Neurological Monitoring for Congenital Heart Surgery
Andropoulos, D. B., Stayer, S. A., Diaz, L. K., & Ramamoorthy, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000134808.52676.4d · Cited by 163
“The INVOS 5100 pediatric sensor tends to read significantly higher (by 14% 8%) than the NIRO 300 4 cm interoptode sensor (pediatric equivalent) (31).”
BackgroundMethodHyttel-Sorensen, S., Sorensen, L. C., Riera, J., & Greisen, G. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003047 · Cited by 92
Weber, F., & Scoones, G. P. (2019) · Pediatric Anesthesia · doi:10.1111/pan.13726 · Cited by 53
Metadata
- Authors
- Watzman, H. M., Kurth, C. D., Montenegro, L. M., Rome, J., Steven, J. M., & Nicolson, S. C.
- Venue
- Anesthesiology
- Published
- 2000-10-01
- Volume
- 93
- Issue
- 4
- Pages
- 947-953
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2011305231
- Cited by
- 451
- References
- 1
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.