Neuronal tissue polarization induced by repetitive transcranial magnetic stimulation?
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In a blinded cross-over design, 10 healthy controls received 900 monophasic and biphasic repetitive transcranial magnetic stimuli over the primary motor cortex. Stimulation frequency was 1 Hz, and stimulation intensity 90% of the individual resting motor threshold. Suprathreshold stimuli applied at 0.1 Hz before and after repetitive stimulation controlled for changes in corticospinal excitability. We found a lasting corticospinal inhibition that was significantly more pronounced after monophasic than after biphasic repetitive transcranial magnetic stimulation (motor evoked potential amplitude reduced by 35 +/- 20% vs 12 +/- 37%, mean+/- s.d.). We propose that the current flow in the coil plays a significant role in optimising after effects, and asymmetric current flow may be particularly efficient in building up tissue polarization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Self-citationSustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Self-citationDepression of motor cortex excitability by low-frequency transcranial magnetic stimulation
Chen, R., Classen, J., Gerloff, C., Celnik, P., Wassermann, E. M., Hallett, M., & Cohen, L. G. (1997) · Neurology · doi:10.1212/wnl.48.5.1398 · Cited by 2,128
Transcranial magnetic stimulation and the human brain
Hallett, M. (2000) · Nature · doi:10.1038/35018000 · Cited by 1,603
Therapeutic application of repetitive transcranial magnetic stimulation: a review
Wassermann, E. M., & Lisanby, S. H. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(01)00585-5 · Cited by 601
Deleterious effects of prolonged electrical excitation of striate cortex in macaques
Bartlett, J. R., Doty, Sr., Lee, B. B., Negrão, N., & Overman, Jr. (2008) · Brain, Behavior and Evolution · doi:10.1159/000125575 · Cited by 52
Cited by
Lefaucheur, J.-P., André-Obadia, N., Antal, A., Ayache, S. S., Baeken, C., Benninger, D. H., Cantello, R. M., Cincotta, M., de Carvalho, M., De Ridder, D., et al. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.021 · Cited by 2,119
Self-citationRossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
“conventional biphasic and monophasic pulses (Antal et al., 2002; Arai et al., 2007, 2005; Hosono et al., 2008; Sommer et al., 2002; Taylor and Loo, 2007; Tings et al., 2005), whereas more recent studies have used cTMS (Sommer et al.”
Self-citationA comprehensive review of the effects of rTMS on motor cortical excitability and inhibition
Fitzgerald, P. B., Fountain, S., & Daskalakis, Z. J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.06.712 · Cited by 1,024
Siebner, H. R., Lang, N., Rizzo, V., Nitsche, M. A., Paulus, W., Lemon, R. N., & Rothwell, J. C. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.5316-03.2004 · Cited by 711
Self-citationRadman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702
Metadata
- Authors
- Sommer, M., Lang, N., Tergau, F., & Paulus, W.
- Venue
- Neuroreport
- Published
- 2002-05
- Volume
- 13
- Issue
- 6
- Pages
- 809-811
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2047573372
- Cited by
- 98
- References
- 6
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neuronal tissue polarization induced by repetitive transcranial magnetic stimulation? https://app.cochat.ai/papers/10.1097/00001756-200205070-00015
- The paper
- Sommer, M., Lang, N., Tergau, F., & Paulus, W. (2002). Neuronal tissue polarization induced by repetitive transcranial magnetic stimulation? Neuroreport. https://doi.org/10.1097/00001756-200205070-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.