Porous Hydroxyapatite and Tricalcium Phosphate Cylinders with Two Different Pore Size Ranges Implanted in the Cancellous Bone of Rabbits: A Comparative Histomorphometric and Histologic Study of Bony Ingrowth and Implant Substitution
The DOI matches its Crossref record.
Abstract
To investigate the histophysiology of implant degradation, hydroxyapatite and tricalcium phosphate cylinders with a diameter of 3 mm were implanted in the cancellous bone of the distal femur and the proximal tibia of 15 New Zealand White rabbits for up to six months. All implants had a homogeneous pore distribution and a porosity of 60%. Ceramics with a pore size range of 50-100 micron and 200-400 micron were compared. Morphometric analysis showed that up to 85.4% of the originally implanted tricalcium phosphate was degraded after six months, whereas the volume reduction of the hydroxyapatite was only 5.4% after the same period. Within the first months bone and tissue ingrowth and implant resorption occurred at a higher rate in the smaller-pored tricalcium phosphate than in the larger-pored material. Hydroxyapatite cylinders with small pores were totally infiltrated by bone or bone marrow after four months, whereas in the larger-pored hydroxyapatite implants tissue did not penetrate all pores after six months and the amount of bone within the implant was small. Scanning electron microscopy of the material before implantation revealed the existence of numerous pore interconnections with diameters of about 20 micron in the smaller-pored ceramics. Such interconnections were rare in the larger-pored implants. The pore interconnections seem to promote vascular and tissue ingrowth and consequently the initial rate of implant resorption. Implant resorption is an active process and involves two different cell types. Acid phosphatase-positive osteoclast-like cells suggesting active resorption adhere directly to the surface, especially in tricalcium phosphate implants. Clusters of macrophages tightly packed with granular material are found in the pores and along the perimeter of all implant cylinders. They may play an active role in the intracellular degradation of small detached ceramic particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone grafts and biomaterials substitutes for bone defect repair: A review
Wang, W., & Yeung, K. W. K. (2017) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.05.007 · Cited by 1,938
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
Calcium orthophosphates in medicine: from ceramics to calcium phosphate cements
Bohner, M. (2000) · Injury · doi:10.1016/s0020-1383(00)80022-4 · Cited by 982
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
β-tricalcium phosphate for bone substitution: Synthesis and properties
Bohner, M., Santoni, B. L. G., & Döbelin, N. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.06.022 · Cited by 762
Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone
Yaszemski, M. J., Payne, R. G., Hayes, W. C., Langer, R., & Mikos, A. G. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85762-0 · Cited by 729
Pore Size of Porous Hydroxyapatite as the Cell-Substratum Controls BMP-Induced Osteogenesis
Tsuruga, E., Takita, H., Itoh, H., Wakisaka, Y., & Kuboki, Y. (1997) · Journal of Biochemistry · doi:10.1093/oxfordjournals.jbchem.a021589 · Cited by 706
Biodegradation and bioresorption of calcium phosphate ceramics
LeGeros, R. Z. (1993) · Clinical Materials · doi:10.1016/0267-6605(93)90049-d · Cited by 647
Osteoconduction at porous hydroxyapatite with various pore configurations
Chang, B.-S., Lee, >. K. >.-K., Hong, K.-S., Youn, H.-J., Ryu, H.-S., Chung, S.-S., & Park, K.-W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00030-2 · Cited by 635
Stem cell technology and bioceramics: From cell to gene engineering
Ohgushi, H., & Caplan, A. I. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:6<913::aid-jbm22>3.0.co;2-0 · Cited by 566
Ramay, H. R., & Zhang, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00171-6 · Cited by 544
Role of interconnections in porous bioceramics on bone recolonization in vitro and in vivo
LU, J. X., FLAUTRE, B., ANSELME, K., HARDOUIN, P., GALLUR, A., DESCAMPS, M., & THIERRY, B. (1999) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008973120918 · Cited by 530
Review of bone graft and bone substitutes with an emphasis on fracture surgeries
Sohn, H.-S., & Oh, J.-K. (2019) · Biomaterials Research · doi:10.1186/s40824-019-0157-y · Cited by 526
Biphasic calcium phosphate ceramics for bone reconstruction: A review of biological response
Bouler, J. M., Pilet, P., Gauthier, O., & Verron, E. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.076 · Cited by 500
Biphasic calcium phosphate nanocomposite porous scaffolds for load-bearing bone tissue engineering
Ramay, H. R. R., & Zhang, M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.023 · Cited by 471
Lam, C. X. F., Savalani, M. M., Teoh, S.-H., & Hutmacher, D. W. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034108 · Cited by 444
Bone reconstruction: from bioceramics to tissue engineering
El-Ghannam, A. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.1.87 · Cited by 415
Bone repair in the twenty–first century: biology, chemistry or engineering?
Hing, K. A. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2004.1466 · Cited by 400
Bioceramic Bone Graft Substitutes: Influence of Porosity and Chemistry
Hing, K. A. (2005) · International Journal of Applied Ceramic Technology · doi:10.1111/j.1744-7402.2005.02020.x · Cited by 365
Porous calcium polyphosphate scaffolds for bone substitute applications — in vitro characterization
Pilliar, R. M., Filiaggi, M. J., Wells, J. D., Grynpas, M. D., & Kandel, R. A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00261-1 · Cited by 359
Roohani-Esfahani, S.-I., Nouri-Khorasani, S., Lu, Z., Appleyard, R., & Zreiqat, H. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.058 · Cited by 342
In vitro and in vivo evaluation of akermanite bioceramics for bone regeneration
Huang, Y., Jin, X., Zhang, X., Sun, H., Tu, J., Tang, T., Chang, J., & Dai, K. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.077 · Cited by 327
Smart fibres, fabrics and clothing
Tao, X. (2001) · Woodhead Publishing Limited eBooks · doi:10.1533/9781855737600 · Cited by 326
Microporosity enhances bioactivity of synthetic bone graft substitutes
Hing, K. A., Annaz, B., Saeed, S., Revell, P. A., & Buckland, T. (2005) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-005-6988-1 · Cited by 325
Tissue responses of calcium phosphate cement: a study in dogs
Yuan, H., Li, Y., de Bruijn, J., de Groot, K., & Zhang, X. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00016-8 · Cited by 304
Biocompatibility and resorption of a brushite calcium phosphate cement
Theiss, F., Apelt, D., Brand, B., Kutter, A., Zlinszky, K., Bohner, M., Matter, S., Frei, C., Auer, J. A., & von Rechenberg, B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.056 · Cited by 304
Comparative performance of three ceramic bone graft substitutes
Hing, K. A., Wilson, L. F., & Buckland, T. (2007) · The Spine Journal · doi:10.1016/j.spinee.2006.07.017 · Cited by 287
In vivo behavior of calcium phosphate scaffolds with four different pore sizes
von Doernberg, M.-C., von Rechenberg, B., Bohner, M., Grünenfelder, S., van Lenthe, G. H., Müller, R., Gasser, B., Mathys, R., Baroud, G., & Auer, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.051 · Cited by 285
Dennis, J. E., Haynesworth, S. E., Young, R. G., & Caplan, A. I. (1992) · Cell Transplantation · doi:10.1177/096368979200100106 · Cited by 280
Advances in Porous Scaffold Design for Bone and Cartilage Tissue Engineering and Regeneration
Cheng, A., Schwartz, Z., Kahn, A., Li, X., Shao, Z., Sun, M., Ao, Y., Boyan, B. D., & Chen, H. (2019) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2018.0119 · Cited by 275
A new method to produce macropores in calcium phosphate cements
del Real, R. P., Wolke, J. G. C., Vallet-Regı́, M., & Jansen, J. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00101-1 · Cited by 265
Ohura, K., Bohner, M., Hardouin, P., Lema�tre, J., Pasquier, G., & Flautre, B. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199602)30:2<193::aid-jbm9>3.0.co;2-m · Cited by 256
Calcium phosphate bone graft substitutes: Failures and hopes
Bohner, M., Galea, L., & Doebelin, N. (2012) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2012.02.028 · Cited by 256
Feng, B., Jinkang, Z., Zhen, W., Jianxi, L., Jiang, C., Jian, L., Guolin, M., & Xin, D. (2011) · Biomedical Materials · doi:10.1088/1748-6041/6/1/015007 · Cited by 252
“In contrast to the conclusion, some researchers observed a faster bone ingrowth with small pores [30, 31].”
BackgroundResultVidal, L., Kampleitner, C., Brennan, M. Á., Hoornaert, A., & Layrolle, P. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00061 · Cited by 239
Lin, L., Chow, K. L., & Leng, Y. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31994 · Cited by 237
“Osteopontin [27] 289, 636 F:50-CCAAGTAAGTCCAACGAAAG-30, R:50-GGTGATGTCCTCGTCTGTA-30 348 NM_001040060”
A review of bioceramic porous scaffolds for hard tissue applications: Effects of structural features
Jodati, H., Yılmaz, B., & Evis, Z. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.03.192 · Cited by 232
Ohgushi, H., Okumura, M., Tamai, S., Shors, E. C., & Caplan, A. I. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820241202 · Cited by 222
Silva, M. M. C. G., Cyster, L. A., Barry, J. J. A., Yang, X. B., Oreffo, R. O. C., Grant, D. M., Scotchford, C. A., Howdle, S. M., Shakesheff, K. M., & Rose, F. R. A. J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.010 · Cited by 222
In vivo evaluation of a bioactive scaffold for bone tissue engineering
Livingston, T., Ducheyne, P., & Garino, J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10157 · Cited by 216
Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes
Hing, K. A., Best, S. M., Tanner, K. E., Bonfield, W., & Revell, P. A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10050 · Cited by 216
Physical and chemical aspects of calcium phosphates used in spinal surgery
M., B. (2001) · European Spine Journal · doi:10.1007/s005860100276 · Cited by 211
Lam, C. X., Teoh, S. H., & Hutmacher, D. W. (2007) · Polymer International · doi:10.1002/pi.2195 · Cited by 209
Craniofacial Tissue Engineering
Alsberg, E., Hill, E. E., & Mooney, D. J. (2001) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411010120010501 · Cited by 193
Bone formation and resorption of highly purified β-tricalcium phosphate in the rat femoral condyle
Kondo, N., Ogose, A., Tokunaga, K., Ito, T., Arai, K., Kudo, N., Inoue, H., Irie, H., & Endo, N. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.026 · Cited by 192
Cyster, L. A., Grant, D. M., Howdle, S. M., Rose, F. R. A. J., Irvine, D. J., Freeman, D., Scotchford, C. A., & Shakesheff, K. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.017 · Cited by 188
Wilson, C. E., de Bruijn, J. D., van Blitterswijk, C. A., Verbout, A. J., & Dhert, W. J. A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20015 · Cited by 184
Mechanism of bone incorporation of β-TCP bone substitute in open wedge tibial osteotomy in patients
Gaasbeek, R. D. A., Toonen, H. G., van Heerwaarden, R. J., & Buma, P. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.056 · Cited by 183
Jensen, S. S., Bornstein, M. M., Dard, M., Bosshardt, D. D., & Buser, D. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31271 · Cited by 180
Shao, H., Ke, X., Liu, A., Sun, M., He, Y., Yang, X., Fu, J., Liu, Y., Zhang, L., Yang, G., et al. (2017) · Biofabrication · doi:10.1088/1758-5090/aa663c · Cited by 172
Tissue engineered bone-regeneration using degradable polymers: The formation of mineralized matrices
Laurencin, C. T., Attawia, M. A., Elgendy, H. E., & Herbert, K. M. (1996) · Bone · doi:10.1016/s8756-3282(96)00132-9 · Cited by 168
Chazono, M., Tanaka, T., Komaki, H., & Fujii, K. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30094 · Cited by 159
Xu, H. H. K., Quinn, J. B., Takagi, S., Chow, L. C., & Eichmiller, F. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011205)57:3<457::aid-jbm1189>3.0.co;2-x · Cited by 158
Synthesis and characterization of porous β-tricalcium phosphate blocks
Bohner, M., van Lenthe, G. H., Grünenfelder, S., Hirsiger, W., Evison, R., & Müller, R. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.026 · Cited by 158
Surface immobilized bisphosphonate improves stainless-steel screw fixation in rats
Tengvall, P., Skoglund, B., Askendal, A., & Aspenberg, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.049 · Cited by 158
Metadata
- Authors
- EGGLI, P. S., MOLLER, W., & SCHENK, R. K.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1988-07
- Volume
- 232
- Issue
- 232
- Pages
- 127-138
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2001619703
- Cited by
- 559
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.