Performance Characteristics of an Eight-Ring Whole Body PET Scanner
The DOI matches its Crossref record.
Abstract
The technical characteristics of the multislice whole-body positron emission tomographic scanner (model PC4096-15WB Scanditronix) and its performance parameters are described. Spatial resolution at the center of the field of view was found to be 4.9 mm in-plane and 4.6 mm (cross slices) and 6.0 mm (direct slices) in the axial direction. The sensitivity for true and scattered coincidences is approximately 5,000 cps for direct slices and 7,100 cps for cross slices. At an activity concentration of 37 kBq/ml the system deadtime was approximately 5%. By measuring a uniform phantom with a cold cylindrical insert (5.0 cm diameter), the scatter fraction was found to be approximately 5%. The mean global uniformity over all 15 slices was 6.5%, whereas the local uniformity was found to be 4.3%. No systematic nonuniformities were observed. Finally, various methods for attenuation correction (transmission scan, contour finding, ellipse) were utilized to test their effects on the resulting reconstructed images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rauch, S. L. (1996) · Archives of General Psychiatry · doi:10.1001/archpsyc.1996.01830050014003 · Cited by 1,056
Rauch, S. L. (1994) · Archives of General Psychiatry · doi:10.1001/archpsyc.1994.03950010062008 · Cited by 880
Topographical representations of mental images in primary visual cortex
Kosslyn, S. M., Thompson, W. L., Klm, I. J., & Alpert, N. M. (1995) · Nature · doi:10.1038/378496a0 · Cited by 701
Visual Mental Imagery Activates Topographically Organized Visual Cortex: PET Investigations
Kosslyn, S. M., Alpert, N. M., Thompson, W. L., Maljkovic, V., Weise, S. B., Chabris, C. F., Hamilton, S. E., Rauch, S. L., & Buonanno, F. S. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.3.263 · Cited by 641
Mental rotation of objects versus hands: Neural mechanisms revealed by positron emission tomography
Kosslyn, S. M., Digirolamo, G. J., Thompson, W. L., & Alpert, N. M. (1998) · Psychophysiology · doi:10.1017/s0048577298001516 · Cited by 590
Schacter, D. L., Alpert, N. M., Savage, C. R., Rauch, S. L., & Albert, M. S. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.1.321 · Cited by 552
Role of the Premotor Cortex in Recovery From Middle Cerebral Artery Infarction
Seitz, R. J., Höflich, P., Binkofski, F., Tellmann, L., Herzog, H., & Freund, H.-J. (1998) · Archives of Neurology · doi:10.1001/archneur.55.8.1081 · Cited by 379
Self-citationThe neural circuitry involved in the reading of German words and pseudowords: a PET study
Hagoort, P., Indefrey, P., Brown, C., Herzog, H., Steinmetz, H., & Seitz, R. J. (1999) · Journal of Cognitive Neuroscience · doi:10.1162/089892999563490 · Cited by 300
Self-citationA Positron Emission Tomographic Study of Simple Phobic Symptom Provocation
Rauch, S. L. (1995) · Archives of General Psychiatry · doi:10.1001/archpsyc.1995.03950130020003 · Cited by 298
Functional neuroanatomy of antisaccade eye movements investigated with positron emission tomography.
O'Driscoll, G. A., Alpert, N. M., Matthysse, S. W., Levy, D. L., Rauch, S. L., & Holzman, P. S. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.925 · Cited by 274
Anger in healthy men: a PET study using script-driven imagery
Dougherty, D. D., Shin, L. M., Alpert, N. M., Pitman, R. K., Orr, S. P., Lasko, M., Macklin, M. L., Fischman, A. J., & Rauch, S. L. (1999) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00063-3 · Cited by 258
Jansson, T., Westlin, J. E., Ahlström, H., Lilja, A., Långström, B., & Bergh, J. (1995) · Journal of Clinical Oncology · doi:10.1200/jco.1995.13.6.1470 · Cited by 257
Imagining rotation by endogenous versus exogenous forces: Distinct neural mechanisms
Kosslyn, S. M., Thompson, W. L., Wraga, M., & Alpert, N. M. (2001) · Neuroreport · doi:10.1097/00001756-200108080-00046 · Cited by 248
From PET detectors to PET scanners
Humm, J. L., Rosenfeld, A., & Del Guerra, A. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1266-2 · Cited by 245
A PET investigation of implicit and explicit sequence learning
Rauch, S. L., Savage, C. R., Brown, H. D., Curran, T., Alpert, N. M., Kendrick, A., Fischman, A. J., & Kosslyn, S. M. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030403 · Cited by 241
The Role of Diaschisis in Stroke Recovery
Seitz, R. J., Azari, N. P., Knorr, U., Binkofski, F., Herzog, H., & Freund, H.-J. (1999) · Stroke · doi:10.1161/01.str.30.9.1844 · Cited by 225
Self-citationRegional Differences in the CBF and BOLD Responses to Hypercapnia: A Combined PET and fMRI Study
Rostrup, E., Law, I., Blinkenberg, M., Larsson, H. B. W., Born, A. P., Holm, S., & Paulson, O. B. (2000) · NeuroImage · doi:10.1006/nimg.1999.0526 · Cited by 216
Identifying objects seen from different viewpoints A PET investigation
Kosslyn, S. M., Alpert, N. M., Thompson, W. L., Chabris, C. F., Rauch, S. L., & Anderson, A. K. (1994) · Brain · doi:10.1093/brain/117.5.1055 · Cited by 214
“The PET machine was a GE Scanditronix PC4096 15- slice whole-body tomograph, which we used in its stationary mode {see Rota-Kops et al., 1990).”
Ryu, J.-S., Choi, N. C., Fischman, A. J., Lynch, T. J., & Mathisen, D. J. (2002) · Lung Cancer · doi:10.1016/s0169-5002(01)00332-4 · Cited by 200
“5 mm separation and sensitivity of 5000 cps/ Ci/cc [14].”
Background(1993) · PubMed · Cited by 197
Stephan, K. M. (1999) · Brain · doi:10.1093/brain/122.2.351 · Cited by 190
Krause, B. J., Schmidt, D., Mottaghy, F. M., Taylor, J., Halsband, U., Herzog, H., Tellmann, L., & Müller-Gärtner, H.-W. (1999) · Brain · doi:10.1093/brain/122.2.255 · Cited by 173
Self-citationDougherty, D. D., Rauch, S. L., Deckersbach, T., Marci, C., Loh, R., Shin, L. M., Alpert, N. M., Fischman, A. J., & Fava, M. (2004) · Archives of General Psychiatry · doi:10.1001/archpsyc.61.8.795 · Cited by 161
“A 15-slice whole-body tomograph (model PC4096; Scanditronix/General Electric Medical Systems, Milwaukee, Wis) was used in its stationary mode to acquire the PET data.(62) The slice geometry consists of contiguous slices with center-to-center distance of 6.”
Method11C-Metomidate PET imaging of adrenocortical cancer
Khan, T. S., Sundin, A., Juhlin, C., Långström, B., Bergström, M., & Eriksson, B. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1025-9 · Cited by 107
Striatal glucose consumption in chorea-free subjects at risk of Huntington's disease
Kuwert, T., Boecker, H., Titz, H., Herzog, H., Wang, B. C., Nayak, U., Feinendegen, L. E., Lange, H. W., & Aulich, A. (1993) · Journal of Neurology · doi:10.1007/bf00870669 · Cited by 99
Self-citationFischman, A. J., Alpert, N. M., Livni, E., Ray, S., Sinclair, I., Callahan, R. J., Correia, J. A., Webb, D., Strauss, H. W., & Rubin, R. H. (1993) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.37.6.1270 · Cited by 93
“All projection data were corrected for nonuniformity of detector response, dead time, random coincidences, and scattered radiation (26).”
Metadata
- Authors
- Kops, E. R., Herzog, H., Schmid, A., Holte, S., & Feinendegen, L. E.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1990-05
- Volume
- 14
- Issue
- 3
- Pages
- 437-445
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2061938237
- Cited by
- 194
- References
- 0
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.