CoChat

Bioimpedance spectroscopy technique: intra-, extracellular, and total body water

ARMSTRONG, LAWRENCE E., KENEFICK, ROBERT W., CASTELLANI, JOHN W., RIEBE, DEBORAH, KAVOURAS, STAVROS A., KUZNICKI, JAMES T., MARESH, CARL M. · 1997 · Medicine & Science in Sports & Exercise
Cited by 91

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to test the validity of a multiple frequency bioimpedance spectroscopy (BIS) technique that estimates extracellular fluid volume (ECV), intracellular fluid volume (ICV), and total body water (TBW). Thirteen healthy males (mean +/- SD: age, 23 +/- 3 yr; body mass, 80.6 +/- 14.7 kg) had their TBW and ECV measured by ingesting dilution tracers (7.27 g deuterium oxide, 1.70 g sodium bromide; blood samples at 0 and 4 h). ICV was calculated as TBW minus ECV. Impedance was measured (50-500 kHz) at rest, on a nonconducting surface, with a BIS analyzer. Electrode placement, posture, exercise, food/fluid intake, and ambient temperature were controlled. Dilution measures (TBW, 51.00 +/- 9.30; ECV, 19.88 +/- 3.14; ICV, 31.12 +/- 6.80 L) and BIS volumes (TBW, 50.03 +/- 7.67; ECV, 20.95 +/- 3.33; ICV, 29.04 +/- 4.51 L) were significantly different for ECV (P < 0.01) and ICV (P < 0.05); some individual differences were large. The correlation coefficients of dilution versus BIS volumes (r = 0.93 to 0.96) were significant at P < 0.0001; SEEs were: TBW, 2.23 L; ECV, 1.26 L; and ICV, 1.71 L. We concluded that BIS is valid for between-subject comparisons of body fluid compartments, is appropriate in clinical settings where change in ECV/ICV ratio is important, and should be used by comparing the required level of accuracy to the inherent technique error/variance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199712000-00017

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 91

Metadata

Authors
ARMSTRONG, L. E., KENEFICK, R. W., CASTELLANI, J. W., RIEBE, D., KAVOURAS, S. A., KUZNICKI, J. T., & MARESH, C. M.
Venue
Medicine & Science in Sports & Exercise
Published
1997-12
Volume
29
Issue
12
Pages
1657-1663
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2055869024
Cited by
91
References
3
FWCI
0.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioimpedance spectroscopy technique: intra-, extracellular, and total body water. https://app.cochat.ai/papers/10.1097/00005768-199712000-00017
The paper
ARMSTRONG, L. E., KENEFICK, R. W., CASTELLANI, J. W., RIEBE, D., KAVOURAS, S. A., KUZNICKI, J. T., & MARESH, C. M. (1997). Bioimpedance spectroscopy technique: intra-, extracellular, and total body water. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199712000-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.