Bioimpedance spectroscopy technique: intra-, extracellular, and total body water
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to test the validity of a multiple frequency bioimpedance spectroscopy (BIS) technique that estimates extracellular fluid volume (ECV), intracellular fluid volume (ICV), and total body water (TBW). Thirteen healthy males (mean +/- SD: age, 23 +/- 3 yr; body mass, 80.6 +/- 14.7 kg) had their TBW and ECV measured by ingesting dilution tracers (7.27 g deuterium oxide, 1.70 g sodium bromide; blood samples at 0 and 4 h). ICV was calculated as TBW minus ECV. Impedance was measured (50-500 kHz) at rest, on a nonconducting surface, with a BIS analyzer. Electrode placement, posture, exercise, food/fluid intake, and ambient temperature were controlled. Dilution measures (TBW, 51.00 +/- 9.30; ECV, 19.88 +/- 3.14; ICV, 31.12 +/- 6.80 L) and BIS volumes (TBW, 50.03 +/- 7.67; ECV, 20.95 +/- 3.33; ICV, 29.04 +/- 4.51 L) were significantly different for ECV (P < 0.01) and ICV (P < 0.05); some individual differences were large. The correlation coefficients of dilution versus BIS volumes (r = 0.93 to 0.96) were significant at P < 0.0001; SEEs were: TBW, 2.23 L; ECV, 1.26 L; and ICV, 1.71 L. We concluded that BIS is valid for between-subject comparisons of body fluid compartments, is appropriate in clinical settings where change in ECV/ICV ratio is important, and should be used by comparing the required level of accuracy to the inherent technique error/variance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311
Cited by
Assessment methods in human body composition
Lee, S. Y., & Gallagher, D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e32830b5f23 · Cited by 694
“In normal-weight persons, there is reasonable evidence to conclude that BIS can accurately measure TBW and ECW [10,11].”
BackgroundInfluentialAssessing Hydration Status: The Elusive Gold Standard
Armstrong, L. E. (2007) · Journal of the American College of Nutrition · doi:10.1080/07315724.2007.10719661 · Cited by 643
Self-citationDehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
“However, despite small mean differences and large correlation coefficients, the error variance is always large (13, 98, 170) and well in excess of 2 L for TBW (or ∼ 5% of TBW).”
Self-citationSawka, M. N., Cheuvront, S. N., & Carter, R. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00152.x · Cited by 336
Kavouras, S. A. (2002) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/00075197-200209000-00010 · Cited by 322
Self-citationMild dehydration impairs cognitive performance and mood of men
Ganio, M. S., Armstrong, L. E., Casa, D. J., McDermott, B. P., Lee, E. C., Yamamoto, L. M., Marzano, S., Lopez, R. M., Jimenez, L., Le Bellego, L., et al. (2011) · British Journal of Nutrition · doi:10.1017/s0007114511002005 · Cited by 316
“For EU trials, body weight was stable (20·01 (SD 0·03) %); this difference was equivalent to only 5 ml of water in a total body water of 50·45 litres((30)).”
BackgroundSelf-citationHydration Assessment Techniques
Armstrong, L. E. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00153.x · Cited by 292
Self-citationContemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Moon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Casa, D. J., Clarkson, P. M., & Roberts, W. O. (2005) · Current Sports Medicine Reports · doi:10.1097/01.csmr.0000306194.67241.76 · Cited by 236
“[19]”
Water Intake, Water Balance, and the Elusive Daily Water Requirement
Armstrong, L. E., & Johnson, E. C. (2018) · Nutrients · doi:10.3390/nu10121928 · Cited by 235
“No hydration assessment technique measures intracellular water content or concentration directly [27].”
BackgroundSelf-citationThe Validity of Bioelectrical Impedance Models in Clinical Populations
Buchholz, A. C., Bartok, C., & Schoeller, D. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019005433 · Cited by 229
Gibson, A. L., Holmes, J. C., Desautels, R. L., Edmonds, L. B., & Nuudi, L. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.2.332 · Cited by 212
“Nevertheless, to increase the accuracy of BIA results, it is imperative that the participants receive and follow standard pretest guidelines (12).”
BackgroundMethodBioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass
Earthman, C., Traughber, D., Dobratz, J., & Howell, W. (2007) · Nutrition in Clinical Practice · doi:10.1177/0115426507022004389 · Cited by 209
Mild Dehydration Affects Mood in Healthy Young Women,
Armstrong, L. E., Ganio, M. S., Casa, D. J., Lee, E. C., McDermott, B. P., Klau, J. F., Jimenez, L., Le Bellego, L., Chevillotte, E., & Lieberman, H. R. (2012) · The Journal of Nutrition · doi:10.3945/jn.111.142000 · Cited by 197
Self-citationAssessment of hydration status in a large population
Baron, S., Courbebaisse, M., Lepicard, E. M., & Friedlander, G. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003213 · Cited by 166
“The difference between TBW and ECW contents yields intracellular water (ICW) content((74)).”
BackgroundCreatine supplementation during resistance training in college football athletes
BEMBEN, M. G., BEMBEN, D. A., LOFTISS, D. D., & KNEHANS, A. W. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200110000-00009 · Cited by 130
Creatine Supplementation Increases Total Body Water Without Altering Fluid Distribution.
(2003) · PubMed Central · Cited by 106
Silva, A. M., Matias, C. N., Nunes, C. L., Santos, D. A., Marini, E., Lukaski, H. C., & Sardinha, L. B. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0355-z · Cited by 99
Hypertrophy-type Resistance Training Improves Phase Angle in Young Adult Men and Women
Ribeiro, A., Avelar, A., dos Santos, L., Silva, A., Gobbo, L., Schoenfeld, B., Sardinha, L., & Cyrino, E. (2016) · International Journal of Sports Medicine · doi:10.1055/s-0042-102788 · Cited by 48
The effects of creatine supplementation on selected factors of tennis specific training
Pluim, B. M., Ferrauti, A., Broekhof, F., Deutekom, M., Gotzmann, A., Kuipers, H., & Weber, K. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.022558 · Cited by 39
Cholewa, J. M., Rossi, F. E., MacDonald, C., Hewins, A., Gallo, S., Micenski, A., Norton, L., & Campbell, B. I. (2018) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002048 · Cited by 32
“Bioelectrical impedanc e spectroscopy has been shown to be a valid tool for assessment of TBW and its various co mpartments in young women (4,17,21,22,27).”
MethodTinsley, G. M. (2021) · British Journal of Nutrition · doi:10.1017/s0007114520003578 · Cited by 29
“BIS TBW volume estimates have compared favourably with dilution techniques in prior validation work(14,15).”
MethodMagnesium-creatine supplementation effects on body water
Brilla, L. R., Giroux, M. S., Taylor, A., & Knutzen, K. M. (2003) · Metabolism · doi:10.1016/s0026-0495(03)00188-4 · Cited by 22
Metadata
- Authors
- ARMSTRONG, L. E., KENEFICK, R. W., CASTELLANI, J. W., RIEBE, D., KAVOURAS, S. A., KUZNICKI, J. T., & MARESH, C. M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-12
- Volume
- 29
- Issue
- 12
- Pages
- 1657-1663
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2055869024
- Cited by
- 91
- References
- 4
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.