Passive leg raising predicts fluid responsiveness in the critically ill*
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN: Prospective study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: We investigated 71 mechanically ventilated patients considered for volume expansion. Thirty-one patients had spontaneous breathing activity and/or arrhythmias. INTERVENTIONS: We assessed hemodynamic status at baseline, after PLR, and after volume expansion (500 mL NaCl 0.9% infusion over 10 mins). MEASUREMENTS AND MAIN RESULTS: We recorded aortic blood flow using esophageal Doppler and arterial pulse pressure. We calculated the respiratory variation of pulse pressure in patients without arrhythmias. In 37 patients (responders), aortic blood flow increased by > or =15% after fluid infusion. A PLR increase of aortic blood flow > or =10% predicted fluid responsiveness with a sensitivity of 97% and a specificity of 94%. A PLR increase of pulse pressure > or =12% predicted volume responsiveness with significantly lower sensitivity (60%) and specificity (85%). In 30 patients without arrhythmias or spontaneous breathing, a respiratory variation in pulse pressure > or =12% was of similar predictive value as was PLR increases in aortic blood flow (sensitivity of 88% and specificity of 93%). In patients with spontaneous breathing activity, the specificity of respiratory variations in pulse pressure was poor (46%). CONCLUSIONS: The changes in aortic blood flow induced by PLR predict preload responsiveness in ventilated patients, whereas with arrhythmias and spontaneous breathing activity, respiratory variations of arterial pulse pressure poorly predict preload responsiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citationTotal arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462
Stetz, C. W., Miller, R. G., Kelly, G. E., & Raffin, T. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.6.1001 · Cited by 447
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Reuter, D. A., Felbinger, T. W., Schmidt, C., et al. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1211-z · Cited by 375
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Self-citationCariou, A., Monchi, M., Joly, L.-M., Bellenfant, F., Claessens, Y.-E., Thebert, D., Brunet, F., & Dhainaut, J.-F. (1998) · Critical Care Medicine · doi:10.1097/00003246-199812000-00043 · Cited by 291
Dark, P. M., & Singer, M. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2430-2 · Cited by 245
Noninvasive Monitoring of Cardiac Output in Critically Ill Patients Using Transesophageal Doppler
Valtier, B., Cholley, B., Belot, J.-P., Coussaye, J.-E. D. L., Matéo, J., & Payen, D. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9707031 · Cited by 235
Furukawa, T., Ogura, T., Katayama, Y., & Hiraoka, M. (1998) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1998.274.2.c500 · Cited by 214
Rutlen, D. L., Wackers, F. J., & Zaret, B. L. (1981) · Circulation · doi:10.1161/01.cir.64.1.146 · Cited by 167
Clinical Usefulness of Respiratory Variations in Arterial Pressure
Magder, S. A. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200211-1360cc · Cited by 157
Wave Reflections and the Arterial Pulse
O’Rourke, M. F. (1984) · Archives of Internal Medicine · doi:10.1001/archinte.1984.00350140192026 · Cited by 127
Reich, D. L., Konstadt, S. N., Raissi, S. S., HUBBARD, M. L., & Thys, D. M. (1989) · Critical Care Medicine · doi:10.1097/00003246-198904000-00003 · Cited by 115
Passive Leg Raising Does Not Produce a Significant or Sustained Autotransfusion Effect
Gaffney, F. A., Bastian, B. C., Thal, E. R., Atkins, J. M., & Blomqvist, C. G. (1982) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-198203000-00003 · Cited by 97
Changes in cardiac output after acute blood loss and position change in man
WONG, D. H., O'Connor, D. T., Tremper, K. K., Zaccari, J., THOMPSON, P., & Hill, D. W. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00002 · Cited by 78
Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler
Roeck, M., Jakob, S. M., Böhlen, T., Brander, L., Knuesel, R., & Takala, J. A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1720-4 · Cited by 61
THE CIRCULATORY RESPONSE TO A STANDARD POSTURAL CHANGE IN ISCHAeMIC HEART DISEASE
Thomas, M., & Shillingford, J. P. (1965) · Heart · doi:10.1136/hrt.27.1.17 · Cited by 57
Non-Invasive Cardiac Output Monitoring by Aortic Blood Flow Measurement With the Dynemo 3000
Boulnois, J.-L. G., & Pechoux, T. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009902517388 · Cited by 52
Cited by
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationEASL Clinical Practical Guidelines on the management of acute (fulminant) liver failure
Wendon, J., Cordoba, J., Dhawan, A., Larsen, F. S., Manns, M., Nevens, F., Samuel, D., Simpson, K. J., Yaron, I., & Bernardi, M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.12.003 · Cited by 917
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
Self-citationPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Self-citation
Metadata
- Authors
- Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2006-05
- Volume
- 34
- Issue
- 5
- Pages
- 1402-1407
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2170704093
- Cited by
- 952
- References
- 22
- FWCI
- 76.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.