Passive leg raising predicts fluid responsiveness in the critically ill*
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN: Prospective study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: We investigated 71 mechanically ventilated patients considered for volume expansion. Thirty-one patients had spontaneous breathing activity and/or arrhythmias. INTERVENTIONS: We assessed hemodynamic status at baseline, after PLR, and after volume expansion (500 mL NaCl 0.9% infusion over 10 mins). MEASUREMENTS AND MAIN RESULTS: We recorded aortic blood flow using esophageal Doppler and arterial pulse pressure. We calculated the respiratory variation of pulse pressure in patients without arrhythmias. In 37 patients (responders), aortic blood flow increased by > or =15% after fluid infusion. A PLR increase of aortic blood flow > or =10% predicted fluid responsiveness with a sensitivity of 97% and a specificity of 94%. A PLR increase of pulse pressure > or =12% predicted volume responsiveness with significantly lower sensitivity (60%) and specificity (85%). In 30 patients without arrhythmias or spontaneous breathing, a respiratory variation in pulse pressure > or =12% was of similar predictive value as was PLR increases in aortic blood flow (sensitivity of 88% and specificity of 93%). In patients with spontaneous breathing activity, the specificity of respiratory variations in pulse pressure was poor (46%). CONCLUSIONS: The changes in aortic blood flow induced by PLR predict preload responsiveness in ventilated patients, whereas with arrhythmias and spontaneous breathing activity, respiratory variations of arterial pulse pressure poorly predict preload responsiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citationTotal arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462
Stetz, C. W., Miller, R. G., Kelly, G. E., & Raffin, T. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.6.1001 · Cited by 447
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Reuter, D. A., Felbinger, T. W., Schmidt, C., et al. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1211-z · Cited by 375
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Self-citationCariou, A., Monchi, M., Joly, L.-M., Bellenfant, F., Claessens, Y.-E., Thebert, D., Brunet, F., & Dhainaut, J.-F. (1998) · Critical Care Medicine · doi:10.1097/00003246-199812000-00043 · Cited by 291
Cited by
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationEASL Clinical Practical Guidelines on the management of acute (fulminant) liver failure
Wendon, J., Cordoba, J., Dhawan, A., Larsen, F. S., Manns, M., Nevens, F., Samuel, D., Simpson, K. J., Yaron, I., & Bernardi, M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.12.003 · Cited by 917
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
Self-citationPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Self-citationInternational Evidence-Based Recommendations for Focused Cardiac Ultrasound
Via, G., Hussain, A., Wells, M., Reardon, R., ElBarbary, M., Noble, V. E., Tsung, J. W., Neskovic, A. N., Price, S., Oren-Grinberg, A., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.05.001 · Cited by 587
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Fluid challenges in intensive care: the FENICE study: A global inception cohort study
on behalf of the FENICE Investigators and the ESICM Trial Group, Cecconi, M., Hofer, C., Teboul, J.-L., Pettila, V., Wilkman, E., Molnar, Z., Della Rocca, G., Aldecoa, C., Artigas, A., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3850-x · Cited by 573
Self-citationMurray, M. J., DeBlock, H., Erstad, B., Gray, A., Jacobi, J., Jordan, C., McGee, W., McManus, C., Meade, M., Nix, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002027 · Cited by 517
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482
Self-citationAntonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Levitov, A., Frankel, H. L., Blaivas, M., Kirkpatrick, A. W., Su, E., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001847 · Cited by 440
Passive leg raising: five rules, not a drop of fluid!
Monnet, X., & Teboul, J.-L. (2015) · Critical Care · doi:10.1186/s13054-014-0708-5 · Cited by 425
Self-citationLamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Self-citationCavallaro, F., Sandroni, C., Marano, C., La Torre, G., Mannocci, A., De Waure, C., Bello, G., Maviglia, R., & Antonelli, M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1929-y · Cited by 386
Muller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Monnet, X., & Teboul, J.-L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0994-y · Cited by 317
Self-citationComparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Self-citationDiagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Passive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289
Self-citationFluid Response Evaluation in Sepsis Hypotension and Shock
Douglas, I. S., Alapat, P. M., Corl, K. A., Exline, M. C., Forni, L. G., Holder, A. L., Kaufman, D. A., Khan, A., Levy, M. M., Martin, G. S., et al. (2020) · Chest · doi:10.1016/j.chest.2020.04.025 · Cited by 271
A rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Yang, X., & Du, B. (2014) · Critical Care · doi:10.1186/s13054-014-0650-6 · Cited by 258
Cherpanath, T. G. V., Hirsch, A., Geerts, B. F., Lagrand, W. K., Leeflang, M. M., Schultz, M. J., & Groeneveld, A. B. J. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001556 · Cited by 253
Point-of-Care Ultrasonography for Primary Care Physicians and General Internists
Bhagra, A., Tierney, D. M., Sekiguchi, H., & Soni, N. J. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.08.023 · Cited by 244
Marik, P. E., Levitov, A., Young, A., & Andrews, L. (2013) · Chest · doi:10.1378/chest.12-1274 · Cited by 243
Can one predict fluid responsiveness in spontaneously breathing patients?
De Backer, D., & Pinsky, M. R. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0645-8 · Cited by 231
Self-citationJozwiak, M., Teboul, J.-L., Anguel, N., Persichini, R., Silva, S., Chemla, D., Richard, C., & Monnet, X. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201303-0593oc · Cited by 225
“Hemodynamic and IAP measurements were recorded when the maximal effect of PLR on cardiac index was reached (21).”
BackgroundMethodSelf-citationPréau, S., Saulnier, F., Dewavrin, F., Durocher, A., & Chagnon, J.-L. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181c8fe7a · Cited by 224
“They also found that the use of proximal substitutes of SV, such as aortic blood flow, may be more accurate markers of fluid responsiveness than the use of more distal markers such as radial PP (14).”
BackgroundMethodInfluentialEgi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*
Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318260c6c3 · Cited by 218
“The effects of a passive leg raising test on the pulse contour analysis– derived CI were assessed, as previously described (17, 18).”
MethodSelf-citationHemodynamic Evaluation and Monitoring in the ICU
Pinsky, M. R. (2007) · Chest · doi:10.1378/chest.07-0073 · Cited by 202
Self-citationArterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200
“In such cases, PPV cannot predict fluid responsiveness (51), since the respiratory changes in intrathoracic pressure are irregular, either in rate or in amplitude.”
BackgroundSelf-citationMedical and Surgical Treatment of Acute Right Ventricular Failure
Lahm, T., McCaslin, C. A., Wozniak, T. C., Ghumman, W., Fadl, Y. Y., Obeidat, O. S., Schwab, K., & Meldrum, D. R. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.046 · Cited by 194
“These hanges are more pronounced in patients whose RV operates n the steep portion of the Starling curve, making dynamic hanges in arterial waveform a sensitive indicator of RV re-load dependence (33,34).”
BackgroundMonnet, X., Vidal-Petiot, E., Osman, D., Hamzaoui, O., Durrbach, A., Goujard, C., Miceli, C., Bourée, P., & Richard, C. (2008) · Critical Care · doi:10.1186/cc6806 · Cited by 188
“Acute circulatory failure was defined as a systolic blood pressure of less than or equal to 90 mm Hg (or a decrease of greater than or equal to 50 mm Hg in previously hypertensive patients), the need for vasopressive agents (dopamine of greater than or equal to 5 μg/kg per minute or norepinephrine), or an elevated blo…”
BackgroundSelf-citationMonnet, X., Jabot, J., Maizel, J., Richard, C., & Teboul, J.-L. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206d2a3 · Cited by 185
“Since the hemodynamic effects of PLR vanish a few seconds after the patient is returned to the semirecumbent position (16), the dose of NE was adjusted a few seconds after the end of PLR1.”
BackgroundResultSelf-citationFluid Therapy for Critically Ill Adults With Sepsis: A Review
Zampieri, F. G., Bagshaw, S. M., & Semler, M. W. (2023) · JAMA · doi:10.1001/jama.2023.7560 · Cited by 184
Mahjoub, Y., Touzeau, J., Airapetian, N., Lorne, E., Hijazi, M., Zogheib, E., Tinturier, F., Slama, M., & Dupont, H. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181eb3c21 · Cited by 184
“Several studies have demonstrated the ability of PLR to discriminate between responders and nonresponders to VE in mechanically ventilated patients (2, 3), in spontaneously breathing patients (14, 15), and in patients with arrhythmia (2).”
BackgroundMethodInfluentialHamzaoui, O., Monnet, X., Richard, C., Osman, D., Chemla, D., & Teboul, J.-L. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.ob013e318161fec4 · Cited by 179
Self-citationLafanechère, A., Pène, F., Goulenok, C., Delahaye, A., Mallet, V, Choukroun, G., Chiche, J., Mira, J., & Cariou, A. (2006) · Critical Care · doi:10.1186/cc5044 · Cited by 178
“However, our data are consistent with recently published findings in which the authors employed similar volumes of fluids [25].”
ResultFougères, E., Teboul, J.-L., Richard, C., Osman, D., Chemla, D., & Monnet, X. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181c587fd · Cited by 176
“Measurements were obtained 1 min later (17), after all variables had stabilized.”
BackgroundMethodSelf-citationPottecher, J., Deruddre, S., Teboul, J.-L., Georger, J.-F., Laplace, C., Benhamou, D., Vicaut, E., & Duranteau, J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1966-6 · Cited by 170
“others [21, 24], the unchanged HR throughout our study makes unlikely the possibility of altered sympathetic tone that could have changed the distribution of blood flow within the macro- or microcirculation.”
BackgroundSelf-citationMonnet, X., Bataille, A., Magalhaes, E., Barrois, J., Le Corre, M., Gosset, C., Guerin, L., Richard, C., & Teboul, J.-L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2693-y · Cited by 159
Self-citationRecommendations for the Management of Crush Victims in Mass Disasters
Sever, M. S., Vanholder, R., the RDRTF of ISN Work Group on Recommendations for the Management of Crush Victims in Mass Disasters, Ashkenazi, I., Becker, G., Better, O., Covic, A., De Smet, M., Eckardt, K.-U., Eknoyan, G., et al. (2012) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfs156 · Cited by 158
“Thirst, dry mucosal membranes, impaired capillary refill time, dry axillae, furrowed tongue, decreased skin turgor over the forehead and sternum, increased heart rate, decreased blood pressure, orthostatic hypotension, and rise of blood pressure (or changes in arterial pressure wave form) with passive leg raising may…”
BackgroundResuscitation Guided by Volume Responsiveness Does Not Reduce Mortality in Sepsis: A Meta-Analysis
Ehrman, R. R., Gallien, J. Z., Smith, R. K., Akers, K. G., Malik, A. N., Harrison, N. E., Welch, R. D., Levy, P. D., & Sherwin, R. L. (2019) · Critical Care Explorations · doi:10.1097/cce.0000000000000015 · Cited by 35
“Alternatively, a passive leg raise (PLR), which increases preload by rapid return of blood from the lower extremities to the central circulation, is considered equivalent to an IVF challenge (8).”
BackgroundOsgood, R., Mohan, S., John, L., Stirling, E., & Stirling, S. (2021) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12204 · Cited by 8
Metadata
- Authors
- Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2006-05
- Volume
- 34
- Issue
- 5
- Pages
- 1402-1407
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2170704093
- Cited by
- 952
- References
- 22
- FWCI
- 76.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.