CoChat

A randomized, controlled trial of the role of weaning predictors in clinical decision making*

Tanios, Maged A., Nevins, Michael L., Hendra, Katherine P., Cardinal, Pierre, Allan, Jill E., Naumova, Elena N., Epstein, Scott K. · 2006 · Critical Care Medicine
Cited by 168

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Weaning predictors are often incorporated in protocols to predict weaning outcome for patients on mechanical ventilation. The predictors are used as a decision point in protocols to determine whether a patient may advance to a spontaneous breathing trial. The impact of including predictors in a weaning protocol has not been previously studied. We designed a study to determine the effect of including a weaning predictor (frequency-tidal volume ratio, or f/Vt) in a weaning protocol. DESIGN: Randomized, blinded controlled trial. SETTING: Academic teaching hospitals. PATIENTS: Three hundred and four patients admitted to intensive care units at three academic teaching hospitals. INTERVENTIONS: Patients were screened daily for measures of oxygenation, cough and secretions, adequate mental status, and hemodynamic stability. Patients were randomized to two groups; in one group the f/Vt was measured but not used in the decision to wean (n = 151), but in the other group, f/Vt was measured and used, using a threshold of 105 breaths/min/L (n = 153). Patients passing the screen received a 2-hr spontaneous breathing trial. Patients passing the spontaneous breathing trial were eligible for an extubation attempt. MEASUREMENTS AND MAIN RESULTS: Groups were similar with regard to gender, age, and Acute Physiology and Chronic Health Evaluation II score. The median duration for weaning time was significantly shorter in the group where the weaning predictor was not used (2.0 vs. 3.0 days, p = .04). There was no difference with regard to the extubation failure, in-hospital mortality rate, tracheostomy, or unplanned extubation. CONCLUSIONS: Including a weaning predictor (f/Vt) in a protocol prolonged weaning time. In addition, the predictor did not confer survival benefit or reduce the incidence of extubation failure or tracheostomy. The results of this study indicate that f/Vt should not be used routinely in weaning decision making.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000236546.98861.25

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Tanios, M. A., Nevins, M. L., Hendra, K. P., Cardinal, P., Allan, J. E., Naumova, E. N., & Epstein, S. K.
Venue
Critical Care Medicine
Published
2006-10
Volume
34
Issue
10
Pages
2530-2535
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2143549823
Cited by
168
References
19
FWCI
7.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.