Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Values of central venous pressure of 8-12 mm Hg and of pulmonary artery occlusion pressure of 12-15 mm Hg have been proposed as volume resuscitation targets in recent international guidelines on management of severe sepsis. By analyzing a large number of volume challenges, our aim was to test the significance of the recommended target values in terms of prediction of volume responsiveness. DESIGN: Retrospective study. SETTING: A 24-bed medical intensive care unit. PATIENTS: All consecutive septic patients monitored with a pulmonary artery catheter who underwent a volume challenge between 2001 and 2004. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: A total of 150 volume challenges in 96 patients were reviewed. In 65 instances, the volume challenge resulted in an increase in cardiac index of > or =15% (responders). The pre-infusion central venous pressure was similar in responders and nonresponders (8 +/- 4 vs. 9 +/- 4 mm Hg). The pre-infusion pulmonary artery occlusion pressure was slightly lower in responders (10 +/- 4 vs. 11 +/- 4 mm Hg, p < .05). However, the significance of pulmonary artery occlusion pressure to predict fluid responsiveness was poor and similar to that of central venous pressure, as indicated by low values of areas under the receiver operating characteristic curves (0.58 and 0.63, respectively). A central venous pressure of <8 mm Hg and a pulmonary artery occlusion pressure of <12 mm Hg predicted volume responsiveness with a positive predictive value of only 47% and 54%, respectively. With the knowledge of a low stroke volume index (<30 mL.m), their positive predictive values were still unsatisfactory: 61% and 69%, respectively. When the combination of central venous pressure and pulmonary artery occlusion pressure was considered instead of either pressure alone, the degree of prediction of volume responsiveness was not improved. CONCLUSION: Our study demonstrates that cardiac filling pressures are poor predictors of fluid responsiveness in septic patients. Therefore, their use as targets for volume resuscitation must be discouraged, at least after the early phase of sepsis has concluded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 1×
“These recommendations have been partly based on the results of a randomized study (3) that demonstrated the positive effect on outcome of early goaldirected therapy—targeting a central venous oxygen saturation of 70%—vs.”
BackgroundHanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Dellinger, R. P. (2004) · Critical Care Medicine · Cited by 1,848
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationKumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citation
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
“Although insertion of a PA catheter may provide useful information regarding volume status and cardiac function, these benefits may be confounded by differences in interpretation of the results (413, 414), poor correlation of PA occlusion pressures with clinical response (415), and lack of a PA catheter-based strategy…”
BackgroundSurviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002255 · Cited by 3,652
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
“Characteristics of the Studies Included in Meta-Analysis Author Year Patients No. of Patients Method Inclusion Criteria Mechanical Ventilation Other Comparator Challenge r-ΔSV Area Under the Receiver Operator Characteristic Curve ICU Calvin et al (23) 1981 Various 28 PAC SV N — 250 cc Colloid 0.16 — Reuse et al (24) 1…”
InfluentialA positive fluid balance is an independent prognostic factor in patients with sepsis
Acheampong, A., & Vincent, J.-L. (2015) · Critical Care · doi:10.1186/s13054-015-0970-1 · Cited by 493
Lichtenstein, D. A., Mezière, G. A., Lagoueyte, J.-F., Biderman, P., Goldstein, I., & Gepner, A. (2009) · Chest · doi:10.1378/chest.09-0001 · Cited by 401
Muller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Will This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Monnet, X., & Teboul, J.-L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0994-y · Cited by 317
Self-citationCannesson, M., Pestel, G., Ricks, C., Hoeft, A., & Perel, A. (2011) · Critical Care · doi:10.1186/cc10364 · Cited by 310
Surviving sepsis campaign: research priorities for sepsis and septic shock
Coopersmith, C. M., De Backer, D., Deutschman, C. S., Ferrer, R., Lat, I., Machado, F. R., Martin, G. S., Martin-Loeches, I., Nunnally, M. E., Antonelli, M., et al. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5175-z · Cited by 281
Bundled care for septic shock: An analysis of clinical trials*
Barochia, A. V., Cui, X., Vitberg, D., Suffredini, A. F., OʼGrady, N. P., Banks, S. M., Minneci, P., Kern, S. J., Danner, R. L., Natanson, C., et al. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cb0ddf · Cited by 279
Fluid management and goal-directed therapy as an adjunct to Enhanced Recovery After Surgery (ERAS)
Miller, T. E., Roche, A. M., & Mythen, M. (2015) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-014-0266-y · Cited by 257
Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions
De Backer, D., & Vincent, J.-L. (2018) · Critical Care · doi:10.1186/s13054-018-1959-3 · Cited by 255
Cecconi, M., Parsons, A. K., & Rhodes, A. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32834699cd · Cited by 244
Eskesen, T. G., Wetterslev, M., & Perner, A. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4168-4 · Cited by 225
“mechanically ventilated [12–50] with tidal volumes”
MethodFluid responsiveness: an evolution of our understanding
Marik, P. E., & Lemson, J. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aet590 · Cited by 201
How can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“Analogous to CVP, the prediction of fluid responsiveness by PAOP has been challenged [21], except for extreme values.”
BackgroundSelf-citationNadim, M. K., Kellum, J. A., Davenport, A., Wong, F., Davis, C., Pannu, N., Tolwani, A., Bellomo, R., & Genyk, Y. S. (2012) · Critical Care · doi:10.1186/cc11188 · Cited by 195
“Traditional methods based on clinical examination and static measurements of right atrial and pulmonary artery pressures are of questionable accuracy in predicting volume responsiveness and should be used with caution [49-53].”
MethodPredictors of Acute Kidney Injury in Septic Shock Patients: An Observational Cohort Study
Plataki, M., Kashani, K., Cabello-Garza, J., Maldonado, F., Kashyap, R., Kor, D. J., Gajic, O., & Cartin-Ceba, R. (2011) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05480610 · Cited by 193
“27 ScVO2, 70%, n (%), n 284 40 (53) 59 (44) 0.”
Biais, M., Nouette-Gaulain, K., Cottenceau, V., Revel, P., & Sztark, F. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen277 · Cited by 180
“Weight, kg 67 (14) Body mass index (kg m22) 23 ( 3 )”
BackgroundSepsis: Early Recognition and Optimized Treatment
Kim, H. I., & Park, S. (2019) · Tuberculosis and Respiratory Diseases · doi:10.4046/trd.2018.0041 · Cited by 178
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“…School, 1211 Geneva 14, Switzerland 5 Centre de Recherche en Nutrition Humaine Auvergne, UMR 1019 Nutrition Humaine, INRA, Clermont Université, Service de Nutrition Clinique, CHU de Clermont-Ferrand, 63009 Clermont-Ferrand, France 6 Intensive Care Division, Geneva University Hospitals,…”
InfluentialDellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000298158.12101.41 · Cited by 9
Osgood, R., Mohan, S., John, L., Stirling, E., & Stirling, S. (2021) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12204 · Cited by 8
Metadata
- Authors
- Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 64-68
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2150407122
- Cited by
- 695
- References
- 25
- FWCI
- 25.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.