Visual Acuity and Optical Parameters in Progressive-Power Lenses
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSES: The purposes of this study are to explore the effect of astigmatism and high-order aberrations of progressive-power lenses (PPLs) on visual acuity (VA) and to find a good optical metric for evaluating visual performance of PPLs. METHODS: A Hartmann-Shack (HS) wavefront sensor was used to measure PPLs and human eyes either independently or in combination. An additional channel permits the measurement of VA under the same optical conditions. Measurements were taken in six relevant locations of a PPL and in three eyes of different normal subjects. In every case, we obtained the wavefront aberration as Zernike polynomials expansions, the root mean square (RMS) error, and two metrics on point spread function (PSF): Strehl ratio and the common logarithm of the volume under the PSF normalized to one (Log_Vol_PSF). RESULTS: Aberration coupling of the PPL with the eye tends to equalize the retinal image quality between central and peripheral zones of the progressive lenses. In the corridor of the PPL, the combination of small amounts of coma, trefoil, and astigmatism (total RMS 0.1 mum) does not significantly affect VA. The continuous increase of astigmatism from corridor to outside zones reduces moderately the quality of vision. The highest correlations between optical metrics and VA were found for Log_Vol_PSF of the entire system eye plus PPL. CONCLUSIONS: Ocular aberrations reduce optical quality difference between corridor and peripheral zones of PPLs. In the same way, VA through the corridor is similar to that of eyes without a lens and it decreases slowly toward peripheral locations. VA through PPLs is well predicted by the logarithm of metrics directly related with image spread (Log_Vol_PSF or equivalent) of the complete system of the eye with the lens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metrics of optical quality derived from wave aberrations predict visual performance
Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.8 · Cited by 341
Assessing visual performance with progressive addition lenses
SELENOW, A., BAUER, E. A., ALI, S. R., SPENCER, L. W., & CIUFFREDA, K. J. (2002) · Optometry and Vision Science · doi:10.1097/00006324-200208000-00012 · Cited by 76 · cited 1×
“For typical intermediate office tasks, this kind of lens provides marginally diminished performance compared with single-vision lenses.(2) Clinical surveys of patient acceptance show a small percentage of progressive-power lenses (PPLs) wearers (around 10–15%) with adaptation problems that could be produced by differe…”
BackgroundComparison of aberrations in different types of progressive power lenses
Villegas, E. A., & Artal, P. (2004) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2004.00214.x · Cited by 32
Self-citation
Research works printed but not linked: 49
- Sullivan CM, 1989, Grating visual acuity testing as a means of psychophysical assessment of progressive addition lenses, Optom Vis Sci, 66, 565, 10.1097/00006324-198909000-00001 · doi:10.1097/00006324-198909000-00001
- Kris MJ, 1999, Practitioner trial of SOLA Percepta progressive lenses, Clin Exp Optom, 82, 187, 10.1111/j.1444-0938.1999.tb06641.x · doi:10.1111/j.1444-0938.1999.tb06641.x
- Boroyan HJ, 1995, Lined multifocal wearers prefer progressive addition lenses, J Am Optom Assoc, 66, 296
- Sullivan CM, 1989, Analysis of a progressive addition lens population, Ophthal Physiol Opt, 9, 163, 10.1111/j.1475-1313.1989.tb00837.x · DOI
- Fauquier C, 1995, Vision Science and Its Applications, OSA Technical Digest Series, 151
- Sullivan CM, 1988, Progressive addition and variable focus lenses: a review, Ophthal Physiol Opt, 8, 402, 10.1111/j.1475-1313.1988.tb01177.x · doi:10.1111/j.1475-1313.1988.tb01177.x
- Legge GE, 1987, Tolerance to visual defocus, J Opt Soc Am (A), 4, 851, 10.1364/JOSAA.4.000851 · doi:10.1364/josaa.4.000851
- Campbell FW, 1965, Optical and retinal factors affecting visual resolution, J Physiol (Lond), 181, 576, 10.1113/jphysiol.1965.sp007784 · DOI · Paper page
- Woods RL, 1996, Monocular diplopia caused by ocular aberrations and hyperopic defocus, Vision Res, 36, 3597, 10.1016/0042-6989(96)00092-2 · doi:10.1016/0042-6989(96)00092-2
- Charman WN, 1976, The optical quality of the monochromatic retinal image as a function of focus, Br J Physiol Opt, 31, 119
- Miller AD, 1997, Effect of small focal errors on vision, Optom Vis Sci, 74, 521, 10.1097/00006324-199707000-00020 · doi:10.1097/00006324-199707000-00020
- Artal P, 1995, Through focus image quality of eyes implanted with monofocal and multifocal intraocular lenses, Opt Eng, 34, 772, 10.1117/12.191818 · doi:10.1117/12.191818
- Villegas EA, 2002, Correlation between optical and psychophysical parameters as a function of defocus, Optom Vis Sci, 79, 60
- Campbell FW, 1957, The depth of field of the human eye, Opt Acta, 4, 157, 10.1080/713826091 · DOI
- Tucker J, 1975, The depth‐of‐focus of the human eye for Snellen letters, Am J Optom Physiol Opt, 52, 3, 10.1097/00006324-197501000-00002 · DOI · Paper page
- Atchison DA, 1997, Subjective depth‐of‐focus of the eye, Optom Vis Sci, 74, 511, 10.1097/00006324-199707000-00019 · doi:10.1097/00006324-199707000-00019
- Marcos S, 1999, The depth‐of‐field of the human eye from objective and subjective measurements, Vision Res, 39, 2039, 10.1016/S0042-6989(98)00317-4 · doi:10.1016/s0042-6989(98)00317-4
- Mouroulis P, 1992, Visual instrument image quality metrics and the effects of coma and astigmatism, J Opt Soc Am (A), 9, 34, 10.1364/JOSAA.9.000034 · DOI
- Minkwitz G, 1963, [On the surface astigmatism of a fixed symmetrical aspheric surface.], Opt Acta (Lond), 10, 223
- Volk D, 1962, The omnifocal lens for presbyopia, Arch Ophthalmol, 68, 776, 10.1001/archopht.1962.00960030780012 · doi:10.1001/archopht.1962.00960030780012
- Boudoncle B, 1990, Proceedings of the International Lens Design Conference, Monterey, CA, June 11–14, 1990, 194
- Fowler CW, 1989, A comparison of three methods for the measurement of progressive addition lenses, Ophthal Physiol Opt, 9, 81, 10.1111/j.1475-1313.1989.tb00813.x · DOI
- Spiers T, 2000, Optical Fourier filtering for whole lens assessment of progressive power lenses, Ophthal Physiol Opt, 20, 281, 10.1046/j.1475-1313.2000.00541.x · doi:10.1046/j.1475-1313.2000.00541.x
- Burns D, 1995, Blur due to pupil area when using progressive addition spectacles, Ophthal Physiol Opt, 15, 273, 10.1046/j.1475-1313.1995.9500010b.x · DOI
- Maitenaz B, 1967, Image retienne donnée par une verre correcteur de puissance progressive, Revue d'Optique, 46, 233
- Villegas EA, 2003, Spatially resolved wavefront aberrations of ophthalmic progressive‐power lenses in normal viewing conditions, Optom Vis Sci, 80, 106, 10.1097/00006324-200302000-00006 · doi:10.1097/00006324-200302000-00006 · Paper page
- Liang J, 1994, Objective measurement of wave aberrations of the human eye with the use of a Hartmann‐Shack wave‐front sensor, J Opt Soc Am (A), 11, 1949, 10.1364/JOSAA.11.001949 · DOI · Paper page
- Liang J, 1997, Aberrations and retinal image quality of the normal human eye, J Opt Soc Am (A), 14, 2873, 10.1364/JOSAA.14.002873 · DOI · Paper page
- Prieto PM, 2000, Analysis of the performance of the Hartmann‐Shack sensor in the human eye, J Opt Soc Am (A), 17, 1388, 10.1364/JOSAA.17.001388 · DOI · Paper page
- 1993, Standard for the Safe Use of Lasers: ANSI Z136.1
- Thibos LN, 2000, Vision Science and Its Applications, OSA Trends in Optics and Photonics Series, 232
- Chateau N, 1996, Infrared pupillometry in presbyopes fitted with soft contact lenses, Optom Vis Sci, 73, 733, 10.1097/00006324-199612000-00003 · doi:10.1097/00006324-199612000-00003
- BlendowskeR VillegasEA ArtalP.An analytical model describing aberrations in the progression corridor of progressive addition lenses. Optom Vis Sci (in press).
- Guirao A, 1999, Average optical performance of the human eye as a function of age in a normal population, Invest Ophthalmol Vis Sci, 40, 203
- Artal P, 2002, Contribution of the cornea and internal surfaces to the change of ocular aberrations with age, J Opt Soc Am (A), 19, 137, 10.1364/JOSAA.19.000137 · DOI · Paper page
- I Jspeert JK, 1990, The intraocular straylight function in 129 healthy volunteers; dependence on angle, age and pigmentation, Vision Res, 30, 699, 10.1016/0042-6989(90)90096-4 · DOI · Paper page
- Villegas EA, 2006, The effect of correcting small astigmatisms on visual acuity, Invest Ophthalmol Vis Sci, 47
- Atchison DA, 2005, Noticeable, troublesome and objectionable limits of blur, Vision Res, 45, 1967, 10.1016/j.visres.2005.01.022 · DOI
- Ciuffreda KJ, 2006, ‘Bothersome blur': a functional unit of blur perception, Vision Res, 46, 895, 10.1016/j.visres.2005.10.004 · DOI
- Applegate RA, 2003, Visual acuity as a function of Zernike mode and level of root mean square error, Optom Vis Sci, 80, 97, 10.1097/00006324-200302000-00005 · doi:10.1097/00006324-200302000-00005 · Paper page
- Fernandez EJ, 2002, Adaptive optics visual simulator, J Refract Surg, 18, S634, 10.3928/1081-597X-20020901-27 · DOI
- Artal P, 2004, Neural compensation for the eye's optical aberrations, J Vis, 4, 281, 10.1167/4.4.4 · DOI · Paper page
- Villegas EA, 2005, Is there neural adaptation to the aberrations in progressive power lenses, Invest Ophthalmol Vis Sci, 46
- Plainis S, 2005, The effect of ocular aberrations on steady‐state errors of accommodative response, J Vis, 5, 466, 10.1167/5.5.7 · DOI · Paper page
- Buehren T, 2006, Accommodation stimulus‐response function and retinal image quality, Vision Res, 46, 1633, 10.1016/j.visres.2005.06.009 · DOI
- Cheng H, 2004, A population study on changes in wave aberrations with accommodation, J Vis, 4, 272, 10.1167/4.4.3 · DOI
- Artal P, 2002, Are optical aberrations during accommodation a significant problem for refractive surgery, J Refract Surg, 18, S563, 10.3928/1081-597X-20020901-13 · doi:10.3928/1081-597x-20020901-13
- He JC, 2003, Change in corneal shape and corneal wave‐front aberrations with accommodation, J Vis, 3, 456
- Thibos LN, 2004, Accuracy and precision of objective refraction from wavefront aberrations, J Vis, 4, 329, 10.1167/4.4.9 · DOI · Paper page
Cited by
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00245.x · Cited by 114
Progress in the spectacle correction of presbyopia. Part 2: modern progressive lens technologies
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00246.x · Cited by 87
Visual performance with lenses correcting peripheral refractive errors
Atchison, D. A., Mathur, A., & Varnas, S. R. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000033 · Cited by 29
“However, power variations in these lenses are comparable to progressive lenses, which have been shown to be dominated by second-order aberrations like astigmatism with higher-order aberrations having a minimal impact on optical performance.(38,39)”
BackgroundOptical performance of progressive addition lenses (PALs) with astigmatic prescription
De Lestrange-Anginieur, E., & Kee, C. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-82697-0 · Cited by 9
Does visual acuity predict visual preference in progressive addition lenses?
Legras, R., Vincent, M., & Marin, G. (2023) · Journal of Optometry · doi:10.1016/j.optom.2022.04.003 · Cited by 7
Metadata
- Authors
- VILLEGAS, E. A., & ARTAL, P.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2006-09
- Volume
- 83
- Issue
- 9
- Pages
- 672-681
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2113650777
- Cited by
- 48
- References
- 3
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visual Acuity and Optical Parameters in Progressive-Power Lenses. https://app.cochat.ai/papers/10.1097/01.opx.0000232818.37832.ee
- The paper
- VILLEGAS, E. A., & ARTAL, P. (2006). Visual Acuity and Optical Parameters in Progressive-Power Lenses. Optometry and Vision Science. https://doi.org/10.1097/01.opx.0000232818.37832.ee
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.