Perioperative Blood Pressure Management
The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Intraoperative hypotension is common during noncardiac surgery and associated with myocardial injury, acute kidney injury, and death. Postoperative hypotension is also common and associated with myocardial injury and death, and largely missed by conventional monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KDIGO Clinical Practice Guidelines for Acute Kidney Injury
Khwaja, A. (2012) · Nephron Clinical Practice · doi:10.1159/000339789 · Cited by 8,014
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Fourth universal definition of myocardial infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., ESC Scientific Document Group, Thygesen, K., Alpert, J. S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy462 · Cited by 5,880
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000066 · Cited by 4,347
Effect of urinary extracts from salt-loaded man on urinary sodium excretion by the rat
Brown, P. R., Koutsaimanis, K. G., & de Wardener, H. E. (1972) · Kidney International · doi:10.1038/ki.1972.62 · Cited by 1,729
Walsh, M., Devereaux, P. J., Garg, A. X., Kurz, A., Turan, A., Rodseth, R. N., Cywinski, J., Thabane, L., & Sessler, D. I. (2013) · Anesthesiology · doi:10.1097/aln.0b013e3182a10e26 · Cited by 1,475 · cited 1×
“The association between organ injury and hypotension is a function of both severity and duration, with lower pressures requiring shorter exposures.(6,7,63) A systematic review of 42 studies summarized reported risks of myocardial injury, acute kidney injury, and death depending on the severity and duration of intraope…”
BackgroundSelf-citationCircadian variation of blood-pressure
Millar-Craig, M., Bishop, C., & Raftery, E. B. (1978) · The Lancet · doi:10.1016/s0140-6736(78)92998-7 · Cited by 1,293 · cited 1×
“Within individuals, circadian rhythms, as well as neural and hormonal changes, induce short-term fluctuations in blood pressure.(16,20) Single blood pressure measurements may therefore poorly reflect patients’ blood pressure profiles.”
BackgroundSalmasi, V., Maheshwari, K., Yang, D., Mascha, E. J., Singh, A., Sessler, D. I., & Kurz, A. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001432 · Cited by 1,104 · cited 5×
“With permission from Salmasi et al.(7)”
BackgroundInfluentialSelf-citationFutier, E., Lefrant, J.-Y., Guinot, P.-G., Godet, T., Lorne, E., Cuvillon, P., Bertran, S., Leone, M., Pastene, B., Piriou, V., et al. (2017) · JAMA · doi:10.1001/jama.2017.14172 · Cited by 917
Writing Committee for the VISION Study Investigators, Devereaux, P. J., Biccard, B. M., Sigamani, A., Xavier, D., Chan, M. T. V., Srinathan, S. K., Walsh, M., Abraham, V., Pearse, R., et al. (2017) · JAMA · doi:10.1001/jama.2017.4360 · Cited by 912 · cited 1×
“Mortality after myocardial injury not fulfilling the additional criteria required for a diagnosis of myocardial infarction is nearly as high as after myocardial infarction.(59,60) Baseline patient risk factors such as age and cardiovascular history are far more strongly associated with postoperative acute kidney injur…”
BackgroundSelf-citationIntraoperative hypotension and the risk of postoperative adverse outcomes: a systematic review
Wesselink, E. M., Kappen, T. H., Torn, H. M., Slooter, A. J. C., & van Klei, W. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.036 · Cited by 896 · cited 6×
“The risk of any end-organ injury was slightly increased when mean arterial pressures were sustained at less than 70 mmHg for just 10 min.(63) The risk was moderately increased with exposures to mean arterial pressures less than 65 to 60 mmHg for at least 5 min, or any exposure to mean arterial pressures less than 55 t…”
BackgroundInfluentialScheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854
Association of Intraoperative Hypotension with Acute Kidney Injury after Elective Noncardiac Surgery
Sun, L. Y., Wijeysundera, D. N., Tait, G. A., & Beattie, W. S. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000765 · Cited by 776
Bijker, J. B., van Klei, W. A., Kappen, T. H., van Wolfswinkel, L., Moons, K. G. M., & Kalkman, C. J. (2007) · Anesthesiology · doi:10.1097/01.anes.0000270724.40897.8e · Cited by 710 · cited 7×
“The most common definition was a 20% reduction in systolic blood pressure from baseline.(21) Applying these definitions to a retrospective cohort of more than 15,000 adults who had noncardiac surgery showed that the incidence of intraoperative hypotension varies substantially depending on the selected definition.”
BackgroundMethodInfluentialSessler, D. I., Bloomstone, J. A., Aronson, S., Berry, C., Gan, T. J., Kellum, J. A., Plumb, J., Mythen, M. G., Grocott, M. P. W., Edwards, M. R., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.013 · Cited by 687
Self-citationHatib, F., Jian, Z., Buddi, S., Lee, C., Settels, J., Sibert, K., Rinehart, J., & Cannesson, M. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002300 · Cited by 614 · cited 5×
“proposed a machine learning algorithm that predicts hypotension, defined as mean arterial pressure less than 65 mmHg for at least 1 min, 5 or more min in advance—thus giving clinicians an opportunity to intervene and perhaps prevent hypotension.(49,50) This “hypotension prediction index” indicates the probability of i…”
BackgroundMethodInfluentialMonk, T. G., Bronsert, M. R., Henderson, W. G., Mangione, M. P., Sum-Ping, S. T. J., Bentt, D. R., Nguyen, J. D., Richman, J. S., Meguid, R. A., & Hammermeister, K. E. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000756 · Cited by 610
Global burden of postoperative death
Nepogodiev, D., Martin, J., Biccard, B., Makupe, A., Bhangu, A., Nepogodiev, D., Martin, J., Biccard, B., Makupe, A., Ademuyiwa, A., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(18)33139-8 · Cited by 602
Predictors of Hypotension After Induction of General Anesthesia
Reich, D. L., Hossain, S., Krol, M., Baez, B., Patel, P., Bernstein, A., & Bodian, C. A. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000175214.38450.91 · Cited by 601 · cited 1×
“Hypotension during and after noncardiac surgery is multifactorial in origin, involving combinations of patient, pharmacologic, and procedural factors.(13,14) Intraoperative hypotension occurs despite frequent or even continuous intraoperative hemodynamic monitoring.”
BackgroundATMOSPHERIC OZONE AND FEMORAL FRACTURES
Burton, J. L., Ensell, F. J., Leach, J. F., & Hall, K. A. (1975) · The Lancet · doi:10.1016/s0140-6736(75)92450-2 · Cited by 587
Wijnberge, M., Geerts, B. F., Hol, L., Lemmers, N., Mulder, M. P., Berge, P., Schenk, J., Terwindt, L. E., Hollmann, M. W., Vlaar, A. P., et al. (2020) · JAMA · doi:10.1001/jama.2020.0592 · Cited by 586 · cited 1×
“52 In another small preliminary single-center trial in 68 noncardiac surgery patients, hypotension prediction index–guided blood pressure management markedly reduced the time-weighted average of a mean arterial pressure less than 65 mmHg, as well as the incidence and absolute and relative duration of hypotension compa…”
ResultHeat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Self-citationPerioperative Myocardial Injury After Noncardiac Surgery: Incidence, Mortality, and Characterization
Puelacher, C., Lurati Buse, G., Seeberger, D., Sazgary, L., Marbot, S., Lampart, A., Espinola, J., Kindler, C., Hammerer, A., Seeberger, E., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030114 · Cited by 505 · cited 1×
“Mortality after myocardial injury not fulfilling the additional criteria required for a diagnosis of myocardial infarction is nearly as high as after myocardial infarction.(59,60) Baseline patient risk factors such as age and cardiovascular history are far more strongly associated with postoperative acute kidney injur…”
BackgroundEpidemiology of Anesthesia-related Mortality in the United States, 1999–2005
Li, G., Warner, M., Lang, B. H., Huang, L., & Sun, L. S. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819b5bdc · Cited by 400
Mascha, E. J., Yang, D., Weiss, S., & Sessler, D. I. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000686 · Cited by 387 · cited 1×
“Blood pressure variability is only marginally associated with postoperative mortality.(10) Clinically important hypotension occurs not only during surgery but also between anesthetic induction and incision.”
BackgroundSelf-citationSanders, R. D., Hughes, F., Shaw, A., Thompson, A., Bader, A., Hoeft, A., Williams, D. A., Grocott, M. P. W., Mythen, M. G., Miller, T. E., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.018 · Cited by 346
Self-citationDoes Radial Artery Pressure Accurately Reflect Aortic Pressure?
Pauca, A. L., Wallenhaupt, S. L., Kon, N. D., & Tucker, W. Y. (1992) · Chest · doi:10.1378/chest.102.4.1193 · Cited by 341 · cited 1×
“Radial systolic blood pressure may overestimate central systolic blood pressure due to pulse pressure amplification during propagation of the pulse wave from the heart to the periphery.(32) However, radial blood pressure underestimates central blood pressure in septic patients treated with vasopressors,(33,34) patient…”
BackgroundMyles, P. S., Boney, O., Botti, M., Cyna, A. M., Gan, T. J., Jensen, M. P., Kehlet, H., Kurz, A., De Oliveira, G. S., Peyton, P., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.12.037 · Cited by 340
Self-citationAssociation between complications and death within 30 days after noncardiac surgery
The Vascular Events in Noncardiac Surgery Patients Cohort Evaluation (VISION) Study Investigators, Spence, J., LeManach, Y., Chan, M. T. V., Wang, C. Y., Sigamani, A., Xavier, D., Pearse, R., Alonso-Coello, P., Garutti, I., et al. (2019) · Canadian Medical Association Journal · doi:10.1503/cmaj.190221 · Cited by 337 · cited 1×
“Postoperative deaths are most strongly associated with complications, including myocardial and acute kidney injury.(2) The risk for postoperative myocardial and acute kidney injury is largely determined by baseline factors.”
BackgroundSelf-citationPost-induction hypotension and early intraoperative hypotension associated with general anaesthesia
Südfeld, S., Brechnitz, S., Wagner, J. Y., Reese, P. C., Pinnschmidt, H. O., Reuter, D. A., & Saugel, B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex127 · Cited by 329 · cited 1×
“Clinically important hypotension occurs not only during surgery but also between anesthetic induction and incision.(65) Although the preincision period is short compared to the entire intraoperative duration, in one study it accounted for a third of all hypotension observed throughout the entire anesthetic and was ind…”
BackgroundSelf-citationSessler, D. I., Meyhoff, C. S., Zimmerman, N. M., Mao, G., Leslie, K., Vásquez, S. M., Balaji, P., Alvarez-Garcia, J., Cavalcanti, A. B., Parlow, J. L., et al. (2018) · Anesthesiology · doi:10.1097/aln.0000000000001985 · Cited by 313 · cited 1×
“Postoperative hypotension is common, often prolonged, and associated with myocardial injury and death.(9,67) Postoperative hypotension on general care wards is largely missed by conventional intermittent blood pressure monitoring.”
BackgroundSelf-citationMaheshwari, K. K., Turan, A., Mao, G., Yang, D., Niazi, A. K., Agarwal, D., Sessler, D. I., & Kurz, A. M. (2018) · Anaesthesia · doi:10.1111/anae.14416 · Cited by 284 · cited 1×
“Although the preincision period is short compared to the entire intraoperative duration, in one study it accounted for a third of all hypotension observed throughout the entire anesthetic and was independently associated with major complications.(66) Hypotension occurring before surgical incision is presumably largely…”
BackgroundSelf-citationAccuracy of Cuff-Measured Blood Pressure
Picone, D. S., Schultz, M. G., Otahal, P., Aakhus, S., Al-Jumaily, A. M., Black, J. A., Bos, W. J., Chambers, J. B., Chen, C.-H., Cheng, H.-M., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.05.064 · Cited by 277 · cited 1×
“Additionally, oscillometric monitors use different proprietary algorithms to assess blood pressure from cuff oscillations, and the agreement between oscillometric and intraarterial blood pressure measurements is highly variable.(26) Oscillometric methods exhibit poor measurement performance at blood pressure extremes.”
MethodPreoperative Risk and the Association between Hypotension and Postoperative Acute Kidney Injury
Mathis, M. R., Naik, B. I., Freundlich, R. E., Shanks, A. M., Heung, M., Kim, M., Burns, M. L., Colquhoun, D. A., Rangrass, G., Janda, A., et al. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003063 · Cited by 245
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224 · cited 1×
“Specifically, oscillometric methods overestimate low and underestimate high blood pressures, thus potentially missing both hypotension and hypertension.(27,28) Direct continuous intraarterial blood pressure measurement using an arterial catheter remains the clinical reference method.”
MethodDavies, S. J., Vistisen, S. T., Jian, Z., Hatib, F., & Scheeren, T. W. L. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004121 · Cited by 219 · cited 1×
“In another validation study in 255 patients having major surgery, the hypotension prediction index predicted intraoperative hypotension up to 15 min before the event with a sensitivity and specificity of 81% each.(51) Naturally, the hypotension prediction index algorithm cannot predict hypotension consequent to clinic…”
BackgroundHow to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S. (2020) · Critical Care · doi:10.1186/s13054-020-02859-w · Cited by 214 · cited 1×
“, “damping”) is adequate.(38) Continuous invasive blood pressure monitoring detects twice as many hypotensive minutes, and triggers a third more vasopressor boluses than intermittent oscillometric blood pressure measurements in patients having major noncardiac surgery.”
BackgroundSelf-citationMyocardial injury after non-cardiac surgery: diagnosis and management
Devereaux, P. J., & Szczeklik, W. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz301 · Cited by 205 · cited 1×
“”(61) Although most myocardial injury patients have underlying coronary artery disease, the etiology of myocardial injury after noncardiac surgery seems to predominantly result from oxygen supply–demand mismatch rather than thrombosis.(61,62) Myocardial injury after noncardiac surgery is common, with a reported incide…”
BackgroundDorman, T., Breslow, M. J., Lipsett, P. A., Rosenberg, J. M., Balser, J. R., Almog, Y., & Rosenfeld, B. A. (1998) · Critical Care Medicine · doi:10.1097/00003246-199810000-00014 · Cited by 189
Maheshwari, K., Shimada, T., Yang, D., Khanna, S., Cywinski, J. B., Irefin, S. A., Ayad, S., Turan, A., Ruetzler, K., Qiu, Y., et al. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003557 · Cited by 187 · cited 1×
“However, in another trial of 214 patients having moderate- to high-risk inpatient noncardiac surgery, no reduction in the amount of hypotension was observed in patients randomized to management with hypotension prediction index-guided hemodynamic and fluid management.(54)”
ResultSelf-citationAhuja, S., Mascha, E. J., Yang, D., Maheshwari, K., Cohen, B., Khanna, A. K., Ruetzler, K., Turan, A., & Sessler, D. I. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003048 · Cited by 186 · cited 2×
“For systolic blood pressure, harm begins to accrue below about 90 mmHg, whereas the threshold is about 65 mmHg for mean arterial pressure.(5) Blood pressure variability is only marginally associated with postoperative mortality.”
BackgroundSelf-citationInvasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Wax, D. B., Lin, H.-M., & Leibowitz, A. B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182330286 · Cited by 178 · cited 1×
“Specifically, oscillometric methods overestimate low and underestimate high blood pressures, thus potentially missing both hypotension and hypertension.(27,28) Direct continuous intraarterial blood pressure measurement using an arterial catheter remains the clinical reference method.”
MethodA Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery
Maheshwari, K., Khanna, S., Bajracharya, G. R., Makarova, N., Riter, Q., Raza, S., Cywinski, J. B., Argalious, M., Kurz, A., & Sessler, D. I. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003482 · Cited by 173 · cited 2×
“In pilot randomized trials, continuous noninvasive finger cuff blood pressure monitoring reduced intraoperative hypotension compared to intermittent oscillometric blood pressure monitoring.(24,42) Other blood pressure monitoring methods—such as the hydraulic coupling method,(43) applanation tonometry,(44) the pulse wa…”
BackgroundMethodSelf-citationSurgical and Patient Risk Factors for Severe Arterial Line Complications in Adults
Nuttall, G., Burckhardt, J., Hadley, A., Kane, S., Kor, D., Marienau, M. S., Schroeder, D. R., Handlogten, K., Wilson, G., & Oliver, W. C. (2016) · Anesthesiology · doi:10.1097/aln.0000000000000967 · Cited by 162
Saugel, B., Dueck, R., & Wagner, J. Y. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.001 · Cited by 162 · cited 3×
“Finger cuff devices from various manufacturers use different methods to account for changes in vascular tone, to obtain the finger blood pressure signal, and to estimate brachial blood pressure from finger blood pressure (either by using proprietary scaling algorithms or by calibrating finger blood pressure to oscillo…”
MethodSelf-citationSaugel, B., Hoppe, P., Nicklas, J. Y., Kouz, K., Körner, A., Hempel, J. C., Vos, J. J., Schön, G., & Scheeren, T. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.03.013 · Cited by 154
Self-citationSchneck, E., Schulte, D., Habig, L., Ruhrmann, S., Edinger, F., Markmann, M., Habicher, M., Rickert, M., Koch, C., & Sander, M. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00433-6 · Cited by 145
Predictors of Intraoperative Hypotension and Bradycardia
Cheung, C. C., Martyn, A., Campbell, N. R. C., Frost, S. D., Gilbert, K., Michota, F. A., Seal, D. D., Ghali, W. A., & Khan, N. A. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2014.11.030 · Cited by 134 · cited 1×
“With permission from Turan et al.15 Copyright © 2020, the American Society of Anesthesiologists, Inc. Unauthorized reproduction of this article is prohibited.”
MethodPostoperative Hypotension after Noncardiac Surgery and the Association with Myocardial Injury
Liem, V. G. B., Hoeks, S. E., Mol, K. H. J. M., Potters, J.-W., Grüne, F., Stolker, R. J., & van Lier, F. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003368 · Cited by 134
McEvoy, M. D., Gupta, R., Koepke, E. J., Feldheiser, A., Michard, F., Levett, D. Z. H., Thacker, J. K. M., Hamilton, M. A., Grocott, M. P. W., Mythen, M. G., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.019 · Cited by 127
Self-citationMeng, L., Wang, Y., Zhang, L., & McDonagh, D. L. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000003569 · Cited by 125 · cited 2×
“Autoregulatory mechanisms promote near-constant blood flow across various organ systems within certain blood pressure limits.(16,17) The brain and kidneys are especially protected by robust autoregulation.”
BackgroundAckland, G. L., Brudney, C. S., Cecconi, M., İnce, C., Irwin, M. G., Lacey, J., Pinsky, M. R., Grocott, M. P., Mythen, M. G., Edwards, M., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.011 · Cited by 120
Self-citationRuetzler, K., Khanna, A. K., & Sessler, D. I. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004567 · Cited by 111 · cited 1×
“”(61) Although most myocardial injury patients have underlying coronary artery disease, the etiology of myocardial injury after noncardiac surgery seems to predominantly result from oxygen supply–demand mismatch rather than thrombosis.(61,62) Myocardial injury after noncardiac surgery is common, with a reported incide…”
BackgroundSelf-citationSaugel, B., Reese, P. C., Sessler, D. I., Burfeindt, C., Nicklas, J. Y., Pinnschmidt, H. O., Reuter, D. A., & Südfeld, S. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002703 · Cited by 106 · cited 2×
“Ambulatory blood pressures presumably best reflect the patients’ normal blood pressure.(16,18,64) However, the optimal timing, setting, and technique for ambulatory blood pressure monitoring remain unclear.”
BackgroundSelf-citationKhanna, A. K., Maheshwari, K. K., Mao, G., Liu, L., Perez-Protto, S. E., Chodavarapu, P., Schacham, Y. N., & Sessler, D. I. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003763 · Cited by 106 · cited 1×
“In patients admitted to the intensive care unit after noncardiac surgery, postoperative hypotension is associated with acute kidney injury and a composite of myocardial injury and death.(68) Postoperative hypotension may thus be a potentially modifiable risk factor for organ injury.”
BackgroundSelf-citationNoninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
Dueck, R., Gödje, O. L., & Clopton, P. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9336-2 · Cited by 87
McIlroy, D. R., Bellomo, R., Billings, F. T., Karkouti, K., Prowle, J. R., Shaw, A., & Myles, P. S. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.08.010 · Cited by 87 · cited 1×
“Sessler serum creatinine increase within any 48-h window within the observation period.(56) Myocardial infarction is defined by fourth Universal Definition of Myocardial Infarction.”
Beyond ‘failure to rescue’: the time has come for continuous ward monitoring
Sessler, D. I., & Saugel, B. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.12.003 · Cited by 77 · cited 1×
“Untethered continuous ward vital sign monitors are now available and should be considered when practical.(69)”
BackgroundSelf-citationKim, W. Y., Jun, J. H., Huh, J. W., Hong, S. B., Lim, C., & Koh, Y. (2013) · Shock · doi:10.1097/shk.0000000000000064 · Cited by 76
Naylor, A. J., Sessler, D. I., Maheshwari, K. K., Khanna, A. K., Yang, D., Mascha, E. J., Suleiman, I., Reville, E. M., Cote, D. R., Hutcherson, M. T., et al. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004370 · Cited by 73 · cited 1×
“Continuous invasive blood pressure monitoring detects twice as many hypotensive minutes, and triggers a third more vasopressor boluses than intermittent oscillometric blood pressure measurements in patients having major noncardiac surgery.(39) Noninvasive finger cuff methods using the volume clamp method (also called…”
BackgroundSelf-citationMeidert, A. S., Nold, J. S., Hornung, R., Paulus, A. C., Zwißler, B., & Czerner, S. F. A. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000690 · Cited by 69 · cited 1×
“In pilot randomized trials, continuous noninvasive finger cuff blood pressure monitoring reduced intraoperative hypotension compared to intermittent oscillometric blood pressure monitoring.(24,42) Other blood pressure monitoring methods—such as the hydraulic coupling method,(43) applanation tonometry,(44) the pulse wa…”
MethodKim, S., Song, J., Park, J.-H., Kim, J., Park, Y., & Hwang, G. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318270a6d9 · Cited by 54
A comparison of radial, brachial, and aortic pressures after cardiopulmonary bypass
Gravlee, G. P., Wong, A. B., Adkins, T. G., Case, L. D., & Pauca, A. L. (1989) · Journal of Cardiothoracic Anesthesia · doi:10.1016/0888-6296(89)90006-9 · Cited by 53 · cited 1×
“However, radial blood pressure underestimates central blood pressure in septic patients treated with vasopressors,(33,34) patients having liver transplant surgery,(35) and cardiac surgery patients after cardiopulmonary bypass.(36,37) Invasive blood pressure monitoring is only reliable when the pressure transducer is c…”
BackgroundSaugel, B., Cecconi, M., & Hajjar, L. A. (2018) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2018.06.012 · Cited by 52 · cited 1×
“Finger cuff devices from various manufacturers use different methods to account for changes in vascular tone, to obtain the finger blood pressure signal, and to estimate brachial blood pressure from finger blood pressure (either by using proprietary scaling algorithms or by calibrating finger blood pressure to oscillo…”
MethodSelf-citationBrachial Arterial Pressure Monitoring during Cardiac Surgery Rarely Causes Complications
Singh, A., Bahadorani, B., Wakefield, B. J., Makarova, N., Kumar, P. A., Tong, M. Z.-Y., Sessler, D. I., & Duncan, A. E. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001626 · Cited by 49
Self-citationPredicting hypotension in perioperative and intensive care medicine
Saugel, B., Kouz, K., Hoppe, P., Maheshwari, K. K., & Scheeren, T. (2019) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2019.04.001 · Cited by 39
Self-citationNon-invasive arterial pressure monitoring revisited
Michard, F., Sessler, D. I., & Saugel, B. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5108-x · Cited by 32 · cited 1×
“Other blood pressure monitoring methods—such as the hydraulic coupling method,(43) applanation tonometry,(44) the pulse wave transit time method,(45) or the pulse decomposition method(46)—may prove to be important alternatives to conventional perioperative blood pressure monitoring methods, but all have inherent techn…”
BackgroundSelf-citationLee, M., Weinberg, L., Pearce, B., Scurrah, N., Story, D., Pillai, P., McCall, P., McNicol, L. P., & Peyton, P. J. (2015) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01049-9 · Cited by 31
A glimpse into the future of postoperative arterial blood pressure monitoring
Michard, F., Scheeren, T., & Saugel, B. (2020) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.04.065 · Cited by 21 · cited 1×
“Other blood pressure monitoring methods—such as the hydraulic coupling method,(43) applanation tonometry,(44) the pulse wave transit time method,(45) or the pulse decomposition method(46)—may prove to be important alternatives to conventional perioperative blood pressure monitoring methods, but all have inherent techn…”
BackgroundSelf-citationBriegel, J., Baehner, T., Kreitmeier, A., Conter, P., Fraccaroli, L., Meidert, A. S., Tholl, M., Papadakis, G., Deunert, A., Bauer, A., et al. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003472 · Cited by 20
Cited by
Saugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
Self-citationEffective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
Self-citation
Metadata
- Authors
- Saugel, B., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 2020-11-18
- Volume
- 134
- Issue
- 2
- Pages
- 250-261
- ISSN
- 0003-3022 (ISSN-L)
- 1528-1175
- OpenAlex
- W3102510608
- Cited by
- 191
- References
- 71
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.