Abstract
Background: Pulse oximetry is ubiquitous in anesthesia and is generally a reliable noninvasive measure of arterial oxygen saturation. Concerns regarding the impact of skin pigmentation and race/ethnicity on the accuracy of pulse oximeter accuracy exist. The authors hypothesized a greater prevalence of occult hypoxemia (arterial oxygen saturation [Sa o 2 ] less than 88% despite oxygen saturation measured by pulse oximetry [Sp o2 ] greater than 92%) in patients undergoing anesthesia who self-reported a race/ethnicity other than White. Methods: Demographic and physiologic data, including self-reported race/ethnicity, were extracted from a departmental data warehouse for patients receiving an anesthetic that included at least one arterial blood gas between January 2008 and December 2019. Calculated Sa o 2 values were paired with concurrent Sp o2 values for each patient. Analysis to determine whether Black, Hispanic, Asian, or Other race/ethnicities were associated with occult hypoxemia relative to White race/ethnicity within the Sp o2 range of 92 to 100% was completed. Results: In total, 151,070 paired Sa o 2 –Sp o2 readings (70,722 White; 16,011 Black; 21,223 Hispanic; 8,121 Asian; 34,993 Other) from 46,253 unique patients were analyzed. The prevalence of occult hypoxemia was significantly higher in Black (339 of 16,011 [2.1%]) and Hispanic (383 of 21,223 [1.8%]) versus White (791 of 70,722 [1.1%]) paired Sa o 2 –Sp o2 readings ( P < 0.001 for both). In the multivariable analysis, Black (odds ratio, 1.44 [95% CI, 1.11 to 1.87]; P = 0.006) and Hispanic (odds ratio, 1.31 [95% CI, 1.03 to 1.68]; P = 0.031) race/ethnicity were associated with occult hypoxemia. Asian and Other race/ethnicity were not associated with occult hypoxemia. Conclusions: Self-reported Black and Hispanic race/ethnicity are associated with a greater prevalence of intraoperative occult hypoxemia in the Sp o2 range of 92 to 100% when compared with self-reported White race/ethnicity. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Racial bias in pulse oximetry measurement
Sjoding, M. W., Dickson, R. P., Iwashyna, T. J., Gay, S. E., & Valley, T. S. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2029240 · Cited by 1,114 · cited 11×
“We also performed a sensitivity analysis limited to the 92 to 96% Spo 2 range, as per Sjoding et al.(16) Results were consistent with our primary analysis.”
MethodResultInfluentialEffects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427 · cited 3×
“These findings demonstrated Sao 2 and Spo 2 discrepancies in Black patients at much higher Spo 2 values than previously described.(14,15) These are important and concerning findings, but may not be applicable to a population of patients undergoing anesthetic care.”
BackgroundResultFeiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400 · cited 3×
“These findings demonstrated Sao 2 and Spo 2 discrepancies in Black patients at much higher Spo 2 values than previously described.(14,15) These are important and concerning findings, but may not be applicable to a population of patients undergoing anesthetic care.”
BackgroundResultTaenzer, A. H., Pyke, J. B., McGrath, S. P., & Blike, G. T. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ca7a9b · Cited by 315
Jubran, A., & Tobin, M. J. (1990) · Chest · doi:10.1378/chest.97.6.1420 · Cited by 296
Ries, A. L., Prewitt, L. M., & Johnson, J. J. (1989) · Chest · doi:10.1378/chest.96.2.287 · Cited by 145
Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
Adler, J. N., Hughes, L. A., Vtvilecchia, R., & Jr., C. A. C. (1998) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1998.tb02772.x · Cited by 102
Cited by
Berg, K. M., Bray, J. E., Ng, K.-C., Liley, H. G., Greif, R., Carlson, J. N., Morley, P. T., Drennan, I. R., Smyth, M., Scholefield, B. R., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001179 · Cited by 159
A review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119
Singh, S., Bennett, M. R., Chen, C., Shin, S., Ghanbari, H., & Nelson, B. W. (2024) · Journal of Medical Internet Research · doi:10.2196/62769 · Cited by 53
Racial effects on Masimo pulse oximetry: a laboratory study
Barker, S. J., & Wilson, W. C. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00927-w · Cited by 36
Metadata
- Authors
- Burnett, G. W., Stannard, B., Wax, D. B., Lin, H.-M., Pyram-Vincent, C., DeMaria, S., & Levin, M. A.
- Venue
- Anesthesiology
- Published
- 2022-03-01
- Volume
- 136
- Issue
- 5
- Pages
- 688-696
- ISSN
- 0003-3022 (ISSN-L)
- 1528-1175
- OpenAlex
- W4214688181
- Cited by
- 57
- References
- 7
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-reported Race/Ethnicity and Intraoperative Occult Hypoxemia: A Retrospective Cohort Study. https://app.cochat.ai/papers/10.1097/aln.0000000000004153
- The paper
- Burnett, G. W., Stannard, B., Wax, D. B., Lin, H.-M., Pyram-Vincent, C., DeMaria, S., & Levin, M. A. (2022). Self-reported Race/Ethnicity and Intraoperative Occult Hypoxemia: A Retrospective Cohort Study. Anesthesiology. https://doi.org/10.1097/aln.0000000000004153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.