A Review of Current and Emerging Approaches to Address Failure-to-Rescue
The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Failure-to-Rescue, defined as hospital deaths after adverse events, is an established measure of patient safety and hospital quality. Until recently, approaches used to address failure-to-rescue have been focused primarily on improvement of response to a recognized patient crisis, with limited success in terms of patient outcomes. Less attention has been paid to improving the detection of the crisis. A wealth of retrospective data exist to support the observation that adverse events in general ward patients are preceded by a significant period (on the order of hours) of physiologic deterioration. Thus, the lack of early recognition of physiologic decline plays a major role in the failure-to-rescue problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hospital Nurse Staffing and Patient Mortality, Nurse Burnout, and Job Dissatisfaction
Aiken, L. H. (2002) · JAMA · doi:10.1001/jama.288.16.1987 · Cited by 5,226
Nurse-Staffing Levels and the Quality of Care in Hospitals
Needleman, J., Buerhaus, P., Mattke, S., Stewart, M., & Zelevinsky, K. (2002) · New England Journal of Medicine · doi:10.1056/nejmsa012247 · Cited by 2,241 · cited 2×
“identified problems by improving patient monitoring and prompting more timely interventions.(1,4,11,12) Furthermore, Pronovost et al.”
BackgroundRole of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Validation of a modified Early Warning Score in medical admissions
Subbe, C. P. (2001) · QJM · doi:10.1093/qjmed/94.10.521 · Cited by 1,762 · cited 2×
“An early attempt at validation of one scoring system was made in 2001 by Subbe et al.(27) The study investigated the relationship between a Modified Early Warning Score (MEWS) and increased risk of death or critical care admission.”
Welch, H. G., & Black, W. C. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djq099 · Cited by 1,599
Physician Staffing Patterns and Clinical Outcomes in Critically Ill Patients: A Systematic Review
Pronovost, P. J., Angus, D. C., Dorman, T., Robinson, K. A., Dremsizov, T. T., & Young, T. L. (2002) · JAMA · doi:10.1001/jama.288.17.2151 · Cited by 1,506
Variation in Hospital Mortality Associated with Inpatient Surgery
Ghaferi, A. A., Birkmeyer, J. D., & Dimick, J. B. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0903048 · Cited by 1,465 · cited 1×
“of the complication) and appropriate response (correct management and treatment).(5) Numerous studies have shown widespread problems in both of these areas, identifying”
BackgroundConfidential inquiry into quality of care before admission to intensive care
McQuillan, P., Pilkington, S., Allan, A., Taylor, B., Short, A., Morgan, G., Nielsen, M., Barrett, D., & Smith, G. (1998) · BMJ · doi:10.1136/bmj.316.7148.1853 · Cited by 1,463 · cited 1×
“Numerous studies have shown that warning signs of physiologic instability exist before cardiac arrests.(8,10,14,16,20,24,39,40) Most patients have a period of deterioration that precedes cardiopulmonary events by 6–8 h.”
BackgroundIntroduction of the medical emergency team (MET) system: a cluster-randomised controlled trial
(2005) · The Lancet · doi:10.1016/s0140-6736(05)66733-5 · Cited by 1,301
Han, Y. Y., Carcillo, J. A., Venkataraman, S. T., Clark, R. S. B., Watson, R. S., Nguyen, T. C., Bayir, H., & Orr, R. A. (2005) · Pediatrics · doi:10.1542/peds.2005-1287 · Cited by 1,149
Silber, J. H., Williams, S. V., Krakauer, H., & Schwartz, S. (1992) · Medical Care · doi:10.1097/00005650-199207000-00004 · Cited by 952 · cited 3×
“complication rates, may be more a measure of patient-related factors than quality of care.(1,3) FTR metrics are limited to”
BackgroundClinical Antecedents to In-Hospital Cardiopulmonary Arrest
Schein, R. M. H., Hazday, N., Pena, M., Ruben, B. H., & Sprung, C. L. (1990) · Chest · doi:10.1378/chest.98.6.1388 · Cited by 905 · cited 2×
“Hospitals have not been able to respond to these events early and adequately enough.(7,14,22,26,39,40) The notion of intervention during the time of deterioration, to actually prevent the adverse event, led to the idea of RRS and its executive arm, the RRT.”
BackgroundBuist, M. D. (2002) · BMJ · doi:10.1136/bmj.324.7334.387 · Cited by 815
Kause, J., Smith, G., Prytherch, D., Parr, M., Flabouris, A., & Hillman, K. (2004) · Resuscitation · doi:10.1016/j.resuscitation.2004.05.016 · Cited by 665
FRANKLIN, C., & MATHEW, J. (1994) · Critical Care Medicine · doi:10.1097/00003246-199402000-00014 · Cited by 618
Bellomo, R., Goldsmith, D., Uchino, S., Buckmaster, J., Hart, G., Opdam, H., Silvester, W., Doolan, L., & Gutteridge, G. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000119428.02968.9e · Cited by 510
Buist, M., Bernard, S., Nguyen, T. V., Moore, G., & Anderson, J. (2004) · Resuscitation · doi:10.1016/j.resuscitation.2004.03.005 · Cited by 501
Gao, H., McDonnell, A., Harrison, D. A., Moore, T., Adam, S., Daly, K., Esmonde, L., Goldhill, D. R., Parry, G. J., Rashidian, A., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0532-3 · Cited by 466
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 459 · cited 3×
“Frequent nuisance alarms lead to desensitization of personnel and discounting of alarms.(52) Thus, the implementation of surveillance monitoring requires a different approach to alarm variables than condition monitoring on alarm parameters in terms of static alarm settings as well as notification delay.”
BackgroundInfluentialPhysiological values and procedures in the 24 h before ICU admission from the ward
Goldhill, D. R., White, S. A., & Sumner, A. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00837.x · Cited by 447 · cited 2×
“Hospitals have not been able to respond to these events early and adequately enough.(7,14,22,26,39,40) The notion of intervention during the time of deterioration, to actually prevent the adverse event, led to the idea of RRS and its executive arm, the RRT.”
BackgroundAntecedents to hospital deaths
Hillman, K. M., Bristow, P. J., Chey, T., Daffurn, K., Jacques, T., Norman, S. L., Bishop, G. F., & Simmons, G. (2001) · Internal Medicine Journal · doi:10.1046/j.1445-5994.2001.00077.x · Cited by 440 · cited 1×
“Numerous studies have shown that warning signs of physiologic instability exist before cardiac arrests.(8,10,14,16,20,24,39,40) Most patients have a period of deterioration that precedes cardiopulmonary events by 6–8 h.”
BackgroundBuist, M. D., Burton, P. R., Bernard, S. A., Waxman, B. P., & Anderson, J. (1999) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb123492.x · Cited by 437 · cited 3×
“Hospitals have not been able to respond to these events early and adequately enough.(7,14,22,26,39,40) The notion of intervention during the time of deterioration, to actually prevent the adverse event, led to the idea of RRS and its executive arm, the RRT.”
BackgroundUse of medical emergency team responses to reduce hospital cardiopulmonary arrests
DeVita, M. A. (2004) · Quality and Safety in Health Care · doi:10.1136/qhc.13.4.251 · Cited by 420
The Tension between Needing to Improve Care and Knowing How to Do It
Auerbach, A. D., Landefeld, C. S., & Shojania, K. G. (2007) · New England Journal of Medicine · doi:10.1056/nejmsb070738 · Cited by 411
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Priestley, G., Watson, W., Rashidian, A., Mozley, C., Russell, D., Wilson, J., Cope, J., Hart, D., Kay, D., Cowley, K., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2268-7 · Cited by 374
DeVita, M. A., Smith, G. B., Adam, S. K., Adams-Pizarro, I., Buist, M., Bellomo, R., Bonello, R., Cerchiari, E., Farlow, B., Goldsmith, D., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2009.12.008 · Cited by 366
Bristow, P. J., HIiiman, K. M., Daffum, K., Norman, S. L., Bishop, G. F., Chey, T., Jacques, T. C., & Simmons, E. G. (2000) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2000.tb125627.x · Cited by 354
McGaughey, J., Alderdice, F., Fowler, R., Kapila, A., Mayhew, A., & Moutray, M. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005529.pub2 · Cited by 348
Carayon, P., & Gürses, A. P. (2005) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2004.12.003 · Cited by 343
Physiological abnormalities in early warning scores are related to mortality in adult inpatients †
Goldhill, D. R., & McNarry, A. F. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh113 · Cited by 325
Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Blike, G. T. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181ca7a9b · Cited by 315 · cited 3×
“2) was shown.(61) In an accompanying editorial,(67) Abenstein and”
BackgroundMethodInfluentialSelf-citationSilber, J. H. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530040045039 · Cited by 314
Poor prognosis for existing monitors in the intensive care unit
Tsien, C. L., & Fackler, J. C. (1997) · Critical Care Medicine · doi:10.1097/00003246-199704000-00010 · Cited by 309
The alarm problem and directed attention in dynamic fault management
WOODS, D. D. (1995) · Ergonomics · doi:10.1080/00140139508925274 · Cited by 276
Interruptions in healthcare: Theoretical views
Grundgeiger, T., & Sanderson, P. (2009) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2008.10.001 · Cited by 262
Rapid response systems: A systematic review*
Winters, B. D., Pham, J. C., Hunt, E. A., Guallar, E., Berenholtz, S., & Pronovost, P. J. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000262388.85669.68 · Cited by 257 · cited 2×
“The results of these previous intervention efforts have been mixed, and only weak evidence indicates that they benefit patients.(15,16) Early recognition has been identified as the primary determinant of the success of intervention with RRTs.”
BackgroundResultQu, H., & Gotman, J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.552241 · Cited by 248
Laine, C. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500030072035 · Cited by 235 · cited 1×
“Unanticipated consequences such as new problems,(78,79) failure, or uncertainty to reach the desired goal have been common when complex systems have altered with the goal of improving them.(80,81) The outcomes of most interest are rare (mortality, codes, rescue events, and ICU transfers); the criteria for some outcome…”
BackgroundCan some in-hospital cardio-respiratory arrests be prevented? A prospective survey
Smith, A. F., & Wood, J. (1998) · Resuscitation · doi:10.1016/s0300-9572(98)00056-2 · Cited by 227 · cited 2×
“Hospitals have not been able to respond to these events early and adequately enough.(7,14,22,26,39,40) The notion of intervention during the time of deterioration, to actually prevent the adverse event, led to the idea of RRS and its executive arm, the RRT.”
BackgroundTracking Progress in Patient Safety: An Elusive Target
Pronovost, P. J., Miller, M. R., & Wachter, R. M. (2006) · JAMA · doi:10.1001/jama.296.6.696 · Cited by 189 · cited 1×
“Measurable outcome variables depend on many factors, such as patients, providers, and organizations and their interplay, which remain poorly understood.(76,77) Unanticipated consequences such as new problems,(78,79) failure, or uncertainty to reach the desired goal have been common when complex systems have altered wi…”
BackgroundBehavioural implications of alarm mistrust as a function of task workload
Bliss, J. P., & Dunn, M. C. (2000) · Ergonomics · doi:10.1080/001401300421743 · Cited by 172
Incidence and characteristics of preventable iatrogenic cardiac arrests
Bedell, S. E. (1991) · JAMA · doi:10.1001/jama.265.21.2815 · Cited by 172
Jacques, T. C., Harrison, G. A., McLaws, M., & Kilborn, G. (2006) · Resuscitation · doi:10.1016/j.resuscitation.2005.08.015 · Cited by 152
The 100,000 Lives Campaign: A Scientific and Policy Review
Wachter, R. M., & Pronovost, P. J. (2006) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(06)32080-6 · Cited by 151 · cited 1×
“Unanticipated consequences such as new problems,(78,79) failure, or uncertainty to reach the desired goal have been common when complex systems have altered with the goal of improving them.(80,81) The outcomes of most interest are rare (mortality, codes, rescue events, and ICU transfers); the criteria for some outcome…”
BackgroundMedical patients at high risk for catastrophic deterioration
Sax, F. L., & Charlson, M. E. (1987) · Critical Care Medicine · doi:10.1097/00003246-198705000-00012 · Cited by 146
Watkinson, P., Barber, V. S., Price, J. D., Hann, A., Tarassenko, L., & Young, D. (2006) · Anaesthesia · doi:10.1111/j.1365-2044.2006.04818.x · Cited by 134
Effects of rapid response systems on clinical outcomes: Systematic review and meta‐analysis
Ranji, S. R., Auerbach, A. D., Hurd, C., O’Rourke, K., & Shojania, K. G. (2007) · Journal of Hospital Medicine · doi:10.1002/jhm.238 · Cited by 127
Mature rapid response system and potentially avoidable cardiopulmonary arrests in hospital
Galhotra, S., DeVita, M. A., Simmons, R. L., & Dew, M. A. (2007) · BMJ Quality & Safety · doi:10.1136/qshc.2007.022210 · Cited by 112
Calzavacca, P., Licari, E., Tee, A. K. H., Egi, M., Haase, M., Haase‐Fielitz, A., & Bellomo, R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1229-y · Cited by 102 · cited 4×
“To address the issue of late responses, RRTs were introduced in recognition of the fact that patients show signs of deterioration in the 6–8 h before a cardiac or respiratory arrest.14 The results of these previous intervention efforts have been mixed, and only weak evidence indicates that they benefit patients.15,16…”
BackgroundInfluentialThe median filter as a preprocessor for a patient monitor limit alarm system in intensive care
Mäkivirta, A., Koski, E. M. J., Kari, A., & Sukuvaara, T. (1991) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(91)90039-v · Cited by 99 · cited 1×
“5 per hr per patient.(62) Together, alarm thresholds and notification delay represent points of control that an institution can use to bring an appropriate balance of sensitivity and specificity to surveillance monitoring systems.”
BackgroundImpact of patient monitoring on the diurnal pattern of medical emergency team activation*
Galhotra, S., DeVita, M. A., Simmons, R. L., & Schmid, A. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000218418.16472.8b · Cited by 91
Becker, K., Thull, B., Käsmacher, H., Stemmer, J., Rau, G., Kalff, G., & Zimmermann, H.-J. (1997) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(97)00020-1 · Cited by 82
Tee, A. K. H., Calzavacca, P., Licari, E., Goldsmith, D., & Bellomo, R. (2007) · Critical Care · doi:10.1186/cc6199 · Cited by 81 · cited 2×
“In a recent review of research related to the adoption of medical emergency teams, Tee et al.51 stated: “As the MET call criteria depend heavily on physiologic alteration of signs, poor monitoring equipment, methods and recognition by staff may be a major stumbling block in improving outcomes and RRS performance.””
BackgroundOverdiagnosis and mammography screening
Welch, H. G. (2009) · BMJ · doi:10.1136/bmj.b1425 · Cited by 79
Rethinking Rapid Response Teams
Litvak, E., & Pronovost, P. J. (2010) · JAMA · doi:10.1001/jama.2010.1385 · Cited by 77 · cited 1×
“PS systems build on previous attempts to improve patient evaluation and deterioration detection and have shown promise in addressing aspects of the FTR problem.(19) However, PS systems research remains an underexplored area in the field of FTR.”
BackgroundSchull, M. J., & Redelmeier, D. A. (2000) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2000.tb02038.x · Cited by 70 · cited 1×
“Several studies have shown limited utility for electrocardiogram monitoring of patients with low-risk electrocardiographic patterns,(35,36) and that an electrocardiogram is not necessarily highly reliable in identifying even patients currently undergoing cardiac arrest.(37) In spite of this finding, physicians Approac…”
BackgroundNurse Staffing and Quality of Care in Hospitals in the United States
Needleman, J., Buerhaus, P. I., Mattke, S., Stewart, M. T., & Zelevinsky, K. (2002) · Policy Politics & Nursing Practice · doi:10.1177/152715402237442 · Cited by 64
Fo, O., McCollegan, J., Ba, K., Yy, H., & Ra, O. (2011) · Cited by 61
A Bayesian model for triage decision support
Sadeghi, S., Barzi, A., Sadeghi, N., & King, B. R. (2005) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2005.07.028 · Cited by 61
Making ICU alarms meaningful: a comparison of traditional vs. trend-based algorithms.
Schoenberg, R., Sands Daniel, Z., & Safran, C. (1999) · PubMed · Cited by 54
The Sea of Uncertainty Surrounding Ductal Carcinoma In Situ--The Price of Screening Mammography
Welch, H. G., Woloshin, S., & Schwartz, L. M. (2008) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djn013 · Cited by 47
Saeed, M., & Mark, R. G. (2006) · PubMed Central · Cited by 46
Hollander, J. E., Valentine, S. M., McCuskey, C. F., & Brogan, G. X. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00057-x · Cited by 44
Is Telemetry Monitoring Necessary in Low-Risk Suspected Acute Chest Pain Syndromes?
Snider, A., Papaleo, M., BELDNER, S. J., Park, C., Katechis, D., Galinkin, D., & Fein, A. M. (2002) · CHEST Journal · doi:10.1378/chest.122.2.517 · Cited by 43
Larson, T. S., & Brady, W. J. (2008) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2007.12.003 · Cited by 42 · cited 2×
“oration in advance of adverse occurrences have not demonstrated significant clinical impact.(34,38,56)”
BackgroundOrganizational-Historical Analysis of the “Failure to Respond to Alarm” Problems
Xiao, Y., Seagull, F. J., Nieves-Khouw, F., Barczak, N., & Perkins, S. B. (2004) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2004.836781 · Cited by 40
Kho, A., Rotz, D., Alrahi, K., Cárdenas, W., Ramsey, K., Liebovitz, D., Noskin, G. A., & Watts, C. (2007) · PubMed · Cited by 38
Identifying level one patients
Morrice, A., & Simpson, H. J. (2006) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2006.07.001 · Cited by 13
Detection of hemodynamic changes in clinical monitoring by time-delay neural networks
Parmanto, B., Deneault, L. G., & Denault, A. Y. (2001) · International Journal of Medical Informatics · doi:10.1016/s1386-5056(01)00174-5 · Cited by 7
Towards Automated Sleep State Estimation using a Holter-Oximeter
Chua, C.-P., Garvey, J., Redmond, S. J., Heneghan, C., & McNicholas, W. T. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353210 · Cited by 4
Cited by
Halvorsen, S., Mehilli, J., Cassese, S., Hall, T. S., Abdelhamid, M., Barbato, E., De Hert, S., de Laval, I., Geisler, T., Hinterbuchner, L., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac270 · Cited by 1,141
Burke, J. R., Downey, C., & Almoudaris, A. M. (2022) · Journal of Patient Safety · doi:10.1097/pts.0000000000000720 · Cited by 180
“Previous approaches to the evaluation and prevention of FTR have been limited to manual vital sign checks.(54) The application of continuous monitoring has the perceived benefits of immediate detection but also implies improved data collection and storage through the use of automated systems.”
MethodLiaw, S. Y., Rashasegaran, A., Wong, L. F., Deneen, C. C., Cooper, S., Levett-Jones, T., Goh, H. S., & Ignacio, J. (2018) · Nurse Education Today · doi:10.1016/j.nedt.2017.12.009 · Cited by 65
Metadata
- Authors
- Taenzer, A. H., Pyke, J. B., McGrath, S. P., & Warner, D. S.
- Venue
- Anesthesiology
- Published
- 2011-08-01
- Volume
- 115
- Issue
- 2
- Pages
- 421-431
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2135037476
- Cited by
- 177
- References
- 71
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.