Protective Mechanical Ventilation during General Anesthesia for Open Abdominal Surgery Improves Postoperative Pulmonary Function
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Background: The impact of intraoperative ventilation on postoperative pulmonary complications is not defined. The authors aimed at determining the effectiveness of protective mechanical ventilation during open abdominal surgery on a modified Clinical Pulmonary Infection Score as primary outcome and postoperative pulmonary function. Methods: Prospective randomized, open-label, clinical trial performed in 56 patients scheduled to undergo elective open abdominal surgery lasting more than 2 h. Patients were assigned by envelopes to mechanical ventilation with tidal volume of 9 ml/kg ideal body weight and zero-positive end-expiratory pressure (standard ventilation strategy) or tidal volumes of 7 ml/kg ideal body weight, 10 cm H 2 O positive end-expiratory pressure, and recruitment maneuvers (protective ventilation strategy). Modified Clinical Pulmonary Infection Score, gas exchange, and pulmonary functional tests were measured preoperatively, as well as at days 1, 3, and 5 after surgery. Results: Patients ventilated protectively showed better pulmonary functional tests up to day 5, fewer alterations on chest x-ray up to day 3 and higher arterial oxygenation in air at days 1, 3, and 5 (mmHg; mean ± SD): 77.1 ± 13.0 versus 64.9 ± 11.3 ( P = 0.0006), 80.5 ± 10.1 versus 69.7 ± 9.3 ( P = 0.0002), and 82.1 ± 10.7 versus 78.5 ± 21.7 ( P = 0.44) respectively. The modified Clinical Pulmonary Infection Score was lower in the protective ventilation strategy at days 1 and 3. The percentage of patients in hospital at day 28 after surgery was not different between groups (7 vs. 15% respectively, P = 0.42). Conclusion: A protective ventilation strategy during abdominal surgery lasting more than 2 h improved respiratory function and reduced the modified Clinical Pulmonary Infection Score without affecting length of hospital stay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
(1993) · PubMed · Cited by 3,827
Vincent, J.-L., de Mendonca, A., Cantraine, F., Moreno, R., Takala, J., Suter, P. M., Sprung, C. L., Colardyn, F., & Blecher, S. (1998) · Critical Care Medicine · doi:10.1097/00003246-199811000-00016 · Cited by 3,463
Horan, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Grace Emori, T. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80201-9 · Cited by 2,609
Trends in Hospital Volume and Operative Mortality for High-Risk Surgery
Finks, J. F., Osborne, N. H., & Birkmeyer, J. D. (2011) · New England Journal of Medicine · doi:10.1056/nejmsa1010705 · Cited by 1,355
Horan, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Emori, T. G. (1992) · Infection Control and Hospital Epidemiology · doi:10.2307/30148464 · Cited by 1,167
Smetana, G. W., Lawrence, V. A., & Cornell, J. E. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-8-200604180-00009 · Cited by 1,047
Horlocker, T. (2003) · Regional Anesthesia and Pain Medicine · doi:10.1053/rapm.2003.50046 · Cited by 921
Gajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
Cited by
Postoperative pulmonary complications
Miskovic, A., & Lumb, A. B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex002 · Cited by 1,123
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Self-citationNeto, A. S., Hemmes, S. N. T., Barbas, C. S. V., Beiderlinden, M., Fernandez-Bustamante, A., Futier, E., Gajic, O., El-Tahan, M. R., Ghamdi, A. A. A., Günay, E., et al. (2016) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(16)00057-6 · Cited by 615
Self-citationYoung, C. C., Harris, E. M., Vacchiano, C., Bodnar, S., Bukowy, B., Elliott, R. R. D., Migliarese, J., Ragains, C., Trethewey, B., Woodward, A., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.08.017 · Cited by 435
Self-citationGüldner, A., Kiss, T., Serpa Neto, A., Hemmes, S. N. T., Canet, J., Spieth, P. M., Rocco, P. R. M., Schultz, M. J., Pelosi, P., & Gama de Abreu, M. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000754 · Cited by 432
Self-citationAbbott, T. E. F., Fowler, A. J., Pelosi, P., Gama de Abreu, M., Møller, A. M., Canet, J., Creagh-Brown, B., Mythen, M., Gin, T., Lalu, M. M., et al. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.007 · Cited by 424
Self-citationSerpa Neto, A., Hemmes, S. N. T., Barbas, C. S. V., Beiderlinden, M., Biehl, M., Binnekade, J. M., Canet, J., Fernandez-Bustamante, A., Futier, E., Gajic, O., et al. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000706 · Cited by 348
Self-citationLadha, K., Vidal Melo, M. F., McLean, D. J., Wanderer, J. P., Grabitz, S. D., Kurth, T., & Eikermann, M. (2015) · BMJ · doi:10.1136/bmj.h3646 · Cited by 326
Grant, M. C., Crisafi, C., Alvarez, A., Arora, R. C., Brindle, M. E., Chatterjee, S., Ender, J., Fletcher, N., Gregory, A. J., Gunaydin, S., et al. (2024) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2023.12.006 · Cited by 324
(2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000646 · Cited by 314
Pereira, S. M., Tucci, M. R., Morais, C. C. A., Simões, C. M., Tonelotto, B. F. F., Pompeo, M. S., Kay, F. U., Pelosi, P., Vieira, J. E., & Amato, M. B. P. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002435 · Cited by 307
Self-citationNeto, A. S., Hemmes, S. N., Barbas, C. S., Beiderlinden, M., Fernandez-Bustamante, A., Futier, E., Hollmann, M. W., Jaber, S., Kozian, A., Licker, M., et al. (2014) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(14)70228-0 · Cited by 302
Self-citationWriting Group for the PReVENT Investigators, Simonis, F. D., Serpa Neto, A., Binnekade, J. M., Braber, A., Bruin, K. C. M., Determann, R. M., Goekoop, G.-J., Heidt, J., Horn, J., et al. (2018) · JAMA · doi:10.1001/jama.2018.14280 · Cited by 279
Self-citationFerrando, C., Soro, M., Unzueta, C., Suarez-Sipmann, F., Canet, J., Librero, J., Pozo, N., Peiró, S., Llombart, A., León, I., et al. (2018) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30024-9 · Cited by 257
Odor, P. M., Bampoe, S., Gilhooly, D., Creagh-Brown, B., & Moonesinghe, S. R. (2020) · BMJ · doi:10.1136/bmj.m540 · Cited by 249
Neto, A. S., Simonis, F. D., Barbas, C. S. V., Biehl, M., Determann, R. M., Elmer, J., Friedman, G., Gajic, O., Goldstein, J. N., Linko, R., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001189 · Cited by 246
“Furthermore, both entities may be influenced by mechanical ventilation (13).”
Self-citationCanet, J., Sabaté, S., Mazo, V., Gallart, L., de Abreu, M. G., Belda, J., Langeron, O., Hoeft, A., & Pelosi, P. (2015) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000223 · Cited by 218
Self-citationWorkgroup, F. T. P. Q. I. (. I., Thiele, R. H., Raghunathan, K., Brudney, C. S., Lobo, D. N., Martin, D., Senagore, A., Cannesson, M., Gan, T. J., Mythen, M. M. G., et al. (2016) · Perioperative Medicine · doi:10.1186/s13741-016-0049-9 · Cited by 197
“The concept of “lung protective ventilation” has expanded into the operating room environment and may improve outcomes in patients (Lellouche et al. 2012; Futier et al. 2013; Severgnini et al. 2013).”
BackgroundLow intraoperative tidal volume ventilation with minimal PEEP is associated with increased mortality
Levin, M. A., McCormick, P. J., Lin, H. M., Hosseinian, L., & Fischer, G. W. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aeu054 · Cited by 187
Management of One-lung Ventilation: Impact of Tidal Volume on Complications after Thoracic Surgery
Blank, R. S., Colquhoun, D. A., Durieux, M. E., Kozower, B. D., McMurry, T. L., Bender, S. P., & Naik, B. I. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001100 · Cited by 177
Predicting postoperative pulmonary complications: implications for outcomes and costs
Sabaté, S., Mazo, V., & Canet, J. (2014) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000045 · Cited by 172
Respiratory complications of anaesthesia
Mills, G. H. (2018) · Anaesthesia · doi:10.1111/anae.14137 · Cited by 163
“Intra-operative lung-protective ventilation during abdominal surgery, including low tidal volumes, PEEP and recruitment manoeuvres have also been shown to reduce postoperative Clinical Pulmonary Infection Scores (CPIS) [43].”
Background
Metadata
- Authors
- Severgnini, P., Selmo, G., Lanza, C., Chiesa, A., Frigerio, A., Bacuzzi, A., Dionigi, G., Novario, R., Gregoretti, C., de Abreu, M. G., Schultz, M. J., Jaber, S., Futier, E., Chiaranda, M., & Pelosi, P.
- Venue
- Anesthesiology
- Published
- 2013-06
- Volume
- 118
- Issue
- 6
- Pages
- 1307-1321
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2076991415
- Cited by
- 474
- References
- 42
- FWCI
- 41.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.