Spontaneous Effort During Mechanical Ventilation: Maximal Injury With Less Positive End-Expiratory Pressure*
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Objectives: We recently described how spontaneous effort during mechanical ventilation can cause “pendelluft,” that is, displacement of gas from nondependent (more recruited) lung to dependent (less recruited) lung during early inspiration. Such transfer depends on the coexistence of more recruited (source) liquid-like lung regions together with less recruited (target) solid-like lung regions. Pendelluft may improve gas exchange, but because of tidal recruitment, it may also contribute to injury. We hypothesize that higher positive end-expiratory pressure levels decrease the propensity to pendelluft and that with lower positive end-expiratory pressure levels, pendelluft is associated with improved gas exchange but increased tidal recruitment. Design: Crossover design. Setting: University animal research laboratory. Subjects: Anesthetized landrace pigs. Interventions: Surfactant depletion was achieved by saline lavage in anesthetized pigs, and ventilator-induced lung injury was produced by ventilation with high tidal volume and low positive end-expiratory pressure. Ventilation was continued in each of four conditions: positive end-expiratory pressure (low or optimized positive end-expiratory pressure after recruitment) and spontaneous breathing (present or absent). Tidal recruitment was assessed using dynamic CT and regional ventilation/perfusion using electric impedance tomography. Esophageal pressure was measured using an esophageal balloon manometer. Measurements and Results: Among the four conditions, spontaneous breathing at low positive end-expiratory pressure not only caused the largest degree of pendelluft, which was associated with improved ventilation/perfusion matching and oxygenation, but also generated the greatest tidal recruitment. At low positive end-expiratory pressure, paralysis worsened oxygenation but reduced tidal recruitment. Optimized positive end-expiratory pressure decreased the magnitude of spontaneous efforts (measured by esophageal pressure) despite using less sedation, from –5.6 ± 1.3 to –2.0 ± 0.7 cm H 2 O, while concomitantly reducing pendelluft and tidal recruitment. No pendelluft was observed in the absence of spontaneous effort. Conclusions: Spontaneous effort at low positive end-expiratory pressure improved oxygenation but promoted tidal recruitment associated with pendelluft. Optimized positive end-expiratory pressure (set after lung recruitment) may reverse the harmful effects of spontaneous breathing by reducing inspiratory effort, pendelluft, and tidal recruitment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Driving pressure and survival in the acute respiratory distress syndrome.
Amato, M. B. P., Meade, M. O., Slutsky, A. S., Brochard, L., Costa, E. L. V., Schoenfeld, D. A., Stewart, T. E., Briel, M., Talmor, D., Mercat, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmsa1410639 · Cited by 2,801 · cited 1×
“Because driving pressure (not P plat ) is the most significant prognostic factor during mechanical ventilation in ARDS in patients without inspiratory efforts (32), it might be important to monitor (and minimize) ∆P L (not absolute P L ) to avoid worsening lung injury in patients taking spontaneous breaths.”
BackgroundSelf-citationNeuromuscular Blockers in Early Acute Respiratory Distress Syndrome
Papazian, L., Forel, J.-M., Gacouin, A., Penot-Ragon, C., Perrin, G., Loundou, A., Jaber, S., Arnal, J.-M., Perez, D., Seghboyan, J.-M., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1005372 · Cited by 2,432
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297 · cited 7×
“Minimization of pendelluft, by adequate lung recruitment or by minimizing spontaneous respiratory effort, may lessen the burden of VILI and potentially improve outcome.”
MethodInfluentialRapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Levine, S., Nguyen, T., Taylor, N., Friscia, M. E., Budak, M. T., Rothenberg, P., Zhu, J., Sachdeva, R., Sonnad, S., Kaiser, L. R., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070447 · Cited by 1,577 · cited 1×
“Spontaneous breathing is traditionally encouraged in patients receiving mechanical ventilation (1, 2), and the putative advantages include improved gas exchange (1–4) and lessened propensity to deconditioning of the respiratory muscles, especially the diaphragm (5).”
BackgroundA simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076 · cited 1×
“An esophageal balloon catheter (SmartCath, CareFusion, Yorba Linda, CA) was inserted to measure the esophageal pressure (P es ), and its position was validated as described previously (17).”
MethodPUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638 · cited 1×
“Spontaneous breathing is traditionally encouraged in patients receiving mechanical ventilation (1, 2), and the putative advantages include improved gas exchange (1–4) and lessened propensity to deconditioning of the respiratory muscles, especially the diaphragm (5).”
BackgroundThe Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Spontaneous Effort Causes Occult Pendelluft during Mechanical Ventilation
Yoshida, T., Torsani, V., Gomes, S., De Santis, R. R., Beraldo, M. A., Costa, E. L. V., Tucci, M. R., Zin, W. A., Kavanagh, B. P., & Amato, M. B. P. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201303-0539oc · Cited by 575 · cited 6×
“Finally, we recently described how spontaneous effort during mechanical ventilation may cause “pendelluft,” that is, displacement of gas from nondependent (more recruited, liquid-like regions) to dependent lung (less recruited, solid-like regions) during early inspiration (12) as a consequence of strong contractions o…”
BackgroundInfluentialSelf-citationReversibility of Lung Collapse and Hypoxemia in Early Acute Respiratory Distress Syndrome
Borges, J. B., Okamoto, V. N., Matos, G. F. J., Caramez, M. P. R., Arantes, P. R., Barros, F., Souza, C. E., Victorino, J. A., Kacmarek, R. M., Barbas, C. S. V., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200506-976oc · Cited by 516 · cited 1×
“In patients with ARDS, elevated levels of positive end-expiratory pressure (PEEP) results in increased end-expiratory lung volume (16) and the diaphragm radius of curvature, and may therefore minimize the negative swings in P pl generated by spontaneous effort.”
BackgroundSelf-citationCosta, E. L. V., Borges, J. B., Melo, A., Suarez-Sipmann, F., Toufen, C., Bohm, S. H., & Amato, M. B. P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1447-y · Cited by 506 · cited 1×
“, < 3% of recollapsed lung units) as estimated by an electric impedance tomography (EIT)– based PEEP titration algorithm previously described (18, 19).”
MethodSelf-citation
Cited by
Acute respiratory distress syndrome
Meyer, N. J., Gattinoni, L., & Calfee, C. S. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00439-6 · Cited by 1,144
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Yoshida, T., Fujino, Y., Amato, M. B. P., & Kavanagh, B. P. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0748cp · Cited by 346
Self-citationGrieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
Self-citationThe future of mechanical ventilation: lessons from the present and the past
Gattinoni, L., Marini, J. J., Collino, F., Maiolo, G., Rapetti, F., Tonetti, T., Vasques, F., & Quintel, M. (2017) · Critical Care · doi:10.1186/s13054-017-1750-x · Cited by 279
Zhou, Y., Jin, X., Lv, Y., Wang, P., Yang, Y., Liang, G., Wang, B., & Kang, Y. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4912-z · Cited by 250
Grieco, D. L., Menga, L. S., Eleuteri, D., & Antonelli, M. (2019) · Minerva Anestesiologica · doi:10.23736/s0375-9393.19.13418-9 · Cited by 249
High Positive End-Expiratory Pressure Renders Spontaneous Effort Noninjurious
Morais, C. C. A., Koyama, Y., Yoshida, T., Plens, G. M., Gomes, S., Lima, C. A. S., Ramos, O. P. S., Pereira, S. M., Kawaguchi, N., Yamamoto, H., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201706-1244oc · Cited by 239
Self-citationGrieco, D. L., Menga, L. S., Raggi, V., Bongiovanni, F., Anzellotti, G. M., Tanzarella, E. S., Bocci, M. G., Mercurio, G., Dell’Anna, A. M., Eleuteri, D., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201904-0841oc · Cited by 192
Bertoni, M., Spadaro, S., & Goligher, E. C. (2020) · Critical Care · doi:10.1186/s13054-020-2777-y · Cited by 164
Volume-controlled Ventilation Does Not Prevent Injurious Inflation during Spontaneous Effort
Yoshida, T., Nakahashi, S., Nakamura, M. A. M., Koyama, Y., Roldan, R., Torsani, V., De Santis, R. R., Gomes, S., Uchiyama, A., Amato, M. B. P., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201610-1972oc · Cited by 162
“After establishing acute lung injury, EIT signals were recorded at the sixth intercostal space during pressure-controlled and volume-controlled ventilation with spontaneous breathing (VT, approximately 6 ml $ kg(21)), and they were analyzed with subdivision of the thorax into four (ventrodorsal) zones as previously de…”
BackgroundMethodSelf-citation
Metadata
- Authors
- Yoshida, T., Roldan, R., Beraldo, M. A., Torsani, V., Gomes, S., De Santis, R. R., Costa, E. L. V., Tucci, M. R., Lima, R. G., Kavanagh, B. P., & Amato, M. B. P.
- Venue
- Critical Care Medicine
- Published
- 2016-08
- Volume
- 44
- Issue
- 8
- Pages
- e678-e688
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2304090022
- Cited by
- 185
- References
- 21
- FWCI
- 17.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.