Technological Distractions (Part 2): A Summary of Approaches to Manage Clinical Alarms With Intent to Reduce Alarm Fatigue
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Objective: Alarm fatigue is a widely recognized safety and quality problem where exposure to high rates of clinical alarms results in desensitization leading to dismissal of or slowed response to alarms. Nonactionable alarms are thought to be especially problematic. Despite these concerns, the number of clinical alarm signals has been increasing as an everincreasing number of medical technologies are added to the clinical care environment. Data Sources: PubMed, SCOPUS, Embase, and CINAHL. Study Selection: We performed a systematic review of the literature focused on clinical alarms. We asked a primary key question; “what interventions have been attempted and resulted in the success of reducing alarm fatigue?” and 3-secondary key questions; “what are the negative effects on patients/families; what are the balancing outcomes (unintended consequences of interventions); and what human factor approaches apply to making an effective alarm?” Data Extraction: Articles relevant to the Key Questions were selected through an iterative review process and relevant data was extracted using a standardized tool. Data Synthesis: We found 62 articles that had relevant and usable data for at least one key question. We found that no study used/developed a clear definition of “alarm fatigue.” For our primary key question 1, the relevant studies focused on three main areas: quality improvement/bundled activities; intervention comparisons; and analysis of algorithm-based false and total alarm suppression. All sought to reduce the number of total alarms and/or false alarms to improve the positive predictive value. Most studies were successful to varying degrees. None measured alarm fatigue directly. Conclusions: There is no agreed upon valid metric(s) for alarm fatigue, and the current methods are mostly indirect. Assuming that reducing the number of alarms and/or improving positive predictive value can reduce alarm fatigue, there are promising avenues to address patient safety and quality problem. Further investment is warranted not only in interventions that may reduce alarm fatigue but also in defining how to best measure it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
What is ‘quality of evidence’ and why is it important to clinicians?
Guyatt, G. H., Oxman, A. D., Kunz, R., Vist, G. E., Falck-Ytter, Y., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39490.551019.be · Cited by 3,250
Going from evidence to recommendations
Guyatt, G. H., Oxman, A. D., Kunz, R., Falck-Ytter, Y., Vist, G. E., Liberati, A., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39493.646875.ae · Cited by 1,810
Monitor Alarm Fatigue : An Integrative Review
Cvach, M. (2012) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-46.4.268 · Cited by 632
Self-citationMonitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 459
Self-citationDrew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438
Self-citationNoise in hospital intensive care units—a critical review of a critical topic
Konkani, A., & Oakley, B. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2011.09.003 · Cited by 242
Self-citationDevelopment of Heart and Respiratory Rate Percentile Curves for Hospitalized Children
Bonafide, C. P., Brady, P. W., Keren, R., Conway, P. H., Marsolo, K., & Daymont, C. (2013) · Pediatrics · doi:10.1542/peds.2012-2443 · Cited by 215
Self-citationImproving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context
Görges, M., Markewitz, B. A., & Westenskow, D. R. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819bdfbb · Cited by 211
Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform
Aboukhalil, A., Nielsen, L., Saeed, M., Mark, R. G., & Clifford, G. D. (2008) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.03.003 · Cited by 204
Paine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
Self-citationBonafide, C. P., Lin, R., Zander, M., Graham, C. S., Paine, C. W., Rock, W., Rich, A., Roberts, K. E., Fortino, M., Nadkarni, V. M., et al. (2015) · Journal of Hospital Medicine · doi:10.1002/jhm.2331 · Cited by 180
Self-citationReliability of Conventional and New Pulse Oximetry in Neonatal Patients
Hay, W. W., Rodden, D. J., Collins, S. M., Melara, D. L., Hale, K. A., & Fashaw, L. M. (2002) · Journal of Perinatology · doi:10.1038/sj.jp.7210740 · Cited by 171
Sleep Disruption due to Hospital Noises: A Prospective Evaluation
Buxton, O. M., Ellenbogen, J. M., Wang, W., Carballeira, A., O'Connor, S., Cooper, D., Gordhandas, A. J., McKinney, S. M., & Solet, J. M. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-12-201208070-00472 · Cited by 163
Signal quality and data fusion for false alarm reduction in the intensive care unit
Li, Q., & Clifford, G. D. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2012.07.015 · Cited by 126
A nurses’ alarm fatigue questionnaire: development and psychometric properties
Torabizadeh, C., Yousefinya, A., Zand, F., Rakhshan, M., & Fararouei, M. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9958-x · Cited by 126
Kane-Gill, S. L., O’Connor, M. F., Rothschild, J. M., Selby, N. M., McLean, B., Bonafide, C. P., Cvach, M. M., Hu, X., Konkani, A., Pelter, M. M., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002580 · Cited by 115
Self-citationCropp, A. J., Woods, L. A., Raney, D. J., & Bredle, D. L. (1994) · CHEST Journal · doi:10.1378/chest.105.4.1217 · Cited by 113
A National Online Survey on the Effectiveness of Clinical Alarms
Korniewicz, D. M., Clark, T., & David, Y. (2008) · American Journal of Critical Care · doi:10.4037/ajcc2008.17.1.36 · Cited by 112
Anesthesia Alarms in Context: An Observational Study
Seagull, F. J., & Sanderson, P. M. (2001) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872001775992453 · Cited by 98
Learnability and discriminability of melodic medical equipment alarms*
Sanderson, P. M., Wee, A., & Lacherez, P. F. (2006) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04502.x · Cited by 97
Attitudes and Practices Related to Clinical Alarms
Funk, M., Clark, J. T., Bauld, T. J., Ott, J. C., & Coss, P. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2014315 · Cited by 91
Overlapping Melodic Alarms Are Almost Indiscriminable
Lacherez, P. F., Seah, E. L., & Sanderson, P. M. (2007) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872007x215719 · Cited by 90
Alarm fatigue and its influence on staff performance
Deb, S., & Claudio, D. (2015) · IIE Transactions on Healthcare Systems Engineering · doi:10.1080/19488300.2015.1062065 · Cited by 89
A Team-Based Approach to Reducing Cardiac Monitor Alarms
Dandoy, C. E., Davies, S. M., Flesch, L., Hayward, M., Koons, C., Coleman, K. M., Jacobs, J., McKenna, L. A., Olomajeye, A., Olson, C., et al. (2014) · PEDIATRICS · doi:10.1542/peds.2014-1162 · Cited by 88
Novel Approach to Cardiac Alarm Management on Telemetry Units
Whalen, D. A., Covelle, P. M., Piepenbrink, J. C., Villanova, K. L., Cuneo, C. L., & Awtry, E. H. (2014) · Journal of Cardiovascular Nursing · doi:10.1097/jcn.0000000000000114 · Cited by 79
Daily Electrode Change and Effect on Cardiac Monitor Alarms: An Evidence-Based Practice Approach
Cvach, M. M., Biggs, M., Rothwell, K. J., & Charles-Hudson, C. (2013) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e31827993bc · Cited by 75
Self-citationChen, L., Dubrawski, A., Wang, D., Fiterau, M., Guillame-Bert, M., Bose, E., Kaynar, A. M., Wallace, D. J., Guttendorf, J., Clermont, G., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001660 · Cited by 75
Use of Pagers With an Alarm Escalation System to Reduce Cardiac Monitor Alarm Signals
Cvach, M. M., Frank, R. J., Doyle, P. A., & Khouri-Stevens, Z. (2013) · Journal of Nursing Care Quality · doi:10.1097/ncq.0b013e3182a61887 · Cited by 69
Self-citationBorowski, M., Siebig, S., Wrede, C. E., & Imhoff, M. (2011) · Computational and Mathematical Methods in Medicine · doi:10.1155/2011/143480 · Cited by 66
Fernandes, C. O., Miles, S., de Lucena, C. J. P., & Cowan, D. (2019) · Journal of Medical Internet Research · doi:10.2196/15406 · Cited by 61
Alarm Fatigue: Use of an Evidence-Based Alarm Management Strategy
Turmell, J. W., Coke, L., Catinella, R., Hosford, T., & Majeski, A. (2017) · Journal of Nursing Care Quality · doi:10.1097/ncq.0000000000000223 · Cited by 59
Voepel‐Lewis, T., Parker, M. L., Burke, C. N., Hemberg, J., Perlin, L., Kai, S., & Ramachandran, S. K. (2013) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2013.02.006 · Cited by 55
Varpio, L., Kuziemsky, C. E., MACDONALD, C., & King, W. J. (2011) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e31823eb581 · Cited by 49
Data-Driven Implementation of Alarm Reduction Interventions in a Cardiovascular Surgical ICU
Allan, S. H., Doyle, P. A., Sapirstein, A., & Cvach, M. M. (2016) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2016.11.004 · Cited by 47
Self-citationReducing False Intracranial Pressure Alarms Using Morphological Waveform Features
Scalzo, F., Liebeskind, D. S., & Hu, X. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2210042 · Cited by 45
Self-citationPredictive combinations of monitor alarms preceding in-hospital code blue events
Hu, X., Sapo, M., Nenov, V., Barry, T., Kim, S., Do, D. H., Boyle, N., & Martin, N. A. (2012) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.03.001 · Cited by 45
Self-citationAlarm limit settings for early warning systems to identify at risk patients
Burgess, L. P. A., Herdman, T. H., Berg, B. W., Feaster, W. W., & Hebsur, S. (2009) · Journal of Advanced Nursing · doi:10.1111/j.1365-2648.2009.05048.x · Cited by 42
Effect of Altering Alarm Settings: A Randomized Controlled Study
Cvach, M. M., Rothwell, K. J., Cullen, A. M., Nayden, M. G., Cvach, N., & Pham, J. C. (2015) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-49.3.214 · Cited by 41
Self-citationInfluence of pulse oximeter lower alarm limit on the incidence of hypoxaemia in the recovery room
Leyssius, A. T. V. R., & Kalkman, C. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/79.4.460 · Cited by 33
Salas-Boni, R., Bai, Y., Harris, P. R. E., Drew, B. J., & Hu, X. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.07.016 · Cited by 33
Self-citationReduction of clinically irrelevant alarms in patient monitoring by adaptive time delays
Schmid, F., Goepfert, M. S., Franz, F., Laule, D., Reiter, B., Goetz, A. E., & Reuter, D. A. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9808-2 · Cited by 33
Atyeo, J., & Sanderson, P. M. (2015) · Anaesthesia · doi:10.1111/anae.13020 · Cited by 31
Rayo, M. F., Mansfield, J. A., Eiferman, D. S., Mignery, T., White, S., & Moffatt, S. D. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004137 · Cited by 31
Differences in Alarm Events Between Disposable and Reusable Electrocardiography Lead Wires
Albert, N. M., Murray, T., Bena, J., Slifcak, E., Roach, J. D., Spence, J., & Burkle, A. (2014) · American Journal of Critical Care · doi:10.4037/ajcc2015663 · Cited by 30
Clinical Trial of an Educational Program to Decrease Monitor Alarms in a Medical Intensive Care Unit
Brantley, A., Collins-Brown, S., Kirkland, J., Knapp, M., Pressley, J., Higgins, M. K., & McMurtry, J. P. (2016) · AACN Advanced Critical Care · doi:10.4037/aacnacc2016110 · Cited by 29
Major reduction in alarm frequency with a new pulse oximeter
Bohnhorst, B., & Poets, C. F. (1998) · Intensive Care Medicine · doi:10.1007/s001340050566 · Cited by 29
A data mining approach to reduce the false alarm rate of patient monitors
Baumgartner, B., Rodel, K., & Knoll, A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347345 · Cited by 28
Semi-supervised detection of intracranial pressure alarms using waveform dynamics
Scalzo, F., & Hu, X. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/4/465 · Cited by 27
Self-citationPaterson, E., Sanderson, P. M., Paterson, N. A. B., Liu, D., & Loeb, R. G. (2016) · Anaesthesia · doi:10.1111/anae.13424 · Cited by 26
Novel Pulse Oximetry Sonifications for Neonatal Oxygen Saturation Monitoring: A Laboratory Study
Hinckfuss, K., Sanderson, P. M., Loeb, R. G., Liley, H. G., & Liu, D. (2015) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720815617406 · Cited by 24
An algorithm strategy for precise patient monitoring in a connected healthcare enterprise
Hu, X. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0107-z · Cited by 23
Self-citationComposing alarms: considering the musical aspects of auditory alarm design
Gillard, J., & Schutz, M. (2016) · Neurocase · doi:10.1080/13554794.2016.1253751 · Cited by 21
Harsha, P., Paul, J., Chong, M., Buckley, N., Tidy, A., Clarke, A., Buckley, D. N., Sirko, Z., Vanniyasingam, T., Walsh, J., et al. (2019) · JMIR Medical Informatics · doi:10.2196/14603 · Cited by 20
Bitan, Y., & O’Connor, M. F. (2012) · F1000Research · doi:10.12688/f1000research.1-45.v1 · Cited by 17
Self-citationWhat Are We Missing? Arrhythmia Detection in the Pediatric Intensive Care Unit
Rosman, E. C., Blaufox, A. D., Menco, A., Trope, R., & Seiden, H. (2013) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2013.01.053 · Cited by 17
Biot, L., Holzapfel, L., Becq, G., Mélot, C., & Baconnier, P. (2003) · Journal of Critical Care · doi:10.1016/j.jcrc.2003.10.004 · Cited by 15
Retrospective analysis of pulse oximeter alarm settings in an intensive care unit patient population
Lansdowne, K., Strauss, D. G., & Scully, C. G. (2016) · BMC Nursing · doi:10.1186/s12912-016-0149-3 · Cited by 14
Hemodynamic-impact-based prioritization of ventricular tachycardia alarms
Desai, K., Lexa, M., Matthews, B., & Genç, Ş. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944366 · Cited by 9
Development and experimental evaluation of an alarm concept for an integrated surgical workstation
Schomakers, E.-M., Janß, A., Dell’Anna, J., Ziefle, M., & Radermacher, K. (2016) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2015-0235 · Cited by 8
Colton, K., Dinardo, T., Hu, P., Xiong, W., Hu, E. Z., Reed, G., DuBose, J. J., Stansbury, L. G., Mackenzie, C. F., Chiu, W. C., et al. (2013) · Journal of Trauma Nursing · doi:10.1097/jtn.0000000000000010 · Cited by 6
Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance
Stefanescu, B. M., O’Shea, T. M., Haury, F., Carlo, W. A., & Slaughter, J. C. (2015) · Respiratory Care · doi:10.4187/respcare.04177 · Cited by 4
Cited by
Role of artificial intelligence in patient safety outcomes: systematic literature review
Choudhury, A., & Asan, O. (2020) · JMIR Medical Informatics · doi:10.2196/18599 · Cited by 440
Watson, J., Hutyra, C. A., Clancy, S. M., Chandiramani, A., Bedoya, A., Ilangovan, K., Nderitu, N., & Poon, E. G. (2020) · JAMIA Open · doi:10.1093/jamiaopen/ooz046 · Cited by 95
Metadata
- Authors
- Winters, B. D., Cvach, M. M., Bonafide, C. P., Hu, X., Konkani, A., O’Connor, M. F., Rothschild, J. M., Selby, N. M., Pelter, M. M., McLean, B., & Kane-Gill, S. L.
- Venue
- Critical Care Medicine
- Published
- 2018-01
- Volume
- 46
- Issue
- 1
- Pages
- 130-137
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2767837043
- Cited by
- 170
- References
- 65
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.