Use of automated office blood pressure measurement to reduce the white coat response
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine the possibility of reducing the white coat response using an automated sphygmomanometer designed for office use, the BpTRU. Consecutive patients referred from physicians in the community to an ambulatory blood pressure (ABP) monitoring unit in an academic hospital were included in the study. PARTICIPANTS AND METHODS: A total of 309 patients referred for diagnosis or management of hypertension were studied. Differences between mean awake ABP and BP readings taken by the patient's own physician using a manual sphygmomanometer or the automated BpTRU device with the patient resting alone in the ABP monitoring unit were compared. RESULTS: BP recorded in the examining room using an automated device (132 +/- 19/75 +/- 12) was similar to the mean awake ABP (134 +/- 12/77 +/- 10) with both values being lower (P < 0.001) than the BP recorded on a routine visit to the patient's own family physician (152 +/- 18/87 +/- 11). The coefficient of correlation between the systolic/diastolic ABP and the automated office BP (r = 0.62/0.72) was higher (P < 0.001) than with the family physician's manual BP (r = 0.32/0.48). The prevalence of white coat hypertension in untreated patients (n = 146) was significantly (P < 0.001) lower with automated office BP (16%) compared with the routine family physician BP (55%). CONCLUSION: The white coat response associated with office BP measurements can be virtually eliminated by recording BP with the automated BpTRU device with patients resting alone in a quiet examining room.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Statistics Notes: Some examples of regression towards the mean
Bland, J. M., & Altman, D. G. (1994) · BMJ · doi:10.1136/bmj.309.6957.780 · Cited by 384
Quinn, R. R., Hemmelgarn, B. R., Padwal, R. S., Myers, M. G., Cloutier, L., Bolli, P., McKay, D. W., Khan, N. A., Hill, M. D., Mahon, J., et al. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70378-0 · Cited by 346
Self-citationWhite, W. B., & Anwar, Y. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200104000-00007 · Cited by 213
White coat hypertension is a cardiovascular risk factor: a 10-year follow-up study
Gustavsen, P. H., Høegholm, A., Bang, L. E., & Kristensen, K. S. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001643 · Cited by 192
Beckett, L., & Godwin, M. (2005) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-5-18 · Cited by 175
Shedding light on the Hawthorne studies
Sonnenfeld, J. A. (1985) · Journal of Organizational Behavior · doi:10.1002/job.4030060203 · Cited by 168 · cited 1×
“This phenomenon, known as the Hawthorne Effect [ 14 ], has been reported in numerous studies of physician behaviour, including a previous report from our centre comparing physicians’ routine BP readings with readings taken for research purposes [15].”
ResultPrevalence, Causes, and Consequences of Masked Hypertension: A Meta-analysis
Verberk, W. J., Kessels, A. G. H., & de Leeuw, P. W. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.221 · Cited by 164
Stergiou, G. S., Tzamouranis, D., Protogerou, A., Nasothimiou, E., & Kapralos, C. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283057af6 · Cited by 119 · cited 1×
“Recently, a third device, the Microlife WatchBP Office, has been evaluated for possible use in clinical practice [ 7 ].”
Method
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“Despite the associations between higher BP on both ABPM and HBPM with increased CVD risk, there are important conceptual differences between these 2 measurement methods (Table 10).4 These differences may explain why there is only a moderate correlation between BP on ABPM and HBPM in detecting and differentiating BP ph…”
MethodResultInfluentialSelf-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationDiabetes and hypertension: a position statement by the American Diabetes Association
de Boer, I. H., Bangalore, S., Benetos, A., Davis, A. M., Michos, E. D., Muntner, P., Rossing, P., Zoungas, S., & Bakris, G. (2017) · Diabetes Care · doi:10.2337/dci17-0026 · Cited by 714
“If the patient is alone when the readings are taken, the approach is also useful for diagnosing white-coat hypertension (20).”
BackgroundEffect of systolic and diastolic blood pressure on cardiovascular outcomes
Flint, A. C., Conell, C., Ren, X., Banki, N. M., Chan, S. L., Rao, V. A., Melles, R. B., & Bhatt, D. L. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1803180 · Cited by 684
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Association of office and ambulatory blood pressure with mortality and cardiovascular outcomes
Yang, W.-Y., Melgarejo, J. D., Thijs, L., Zhang, Z.-Y., Boggia, J., Wei, F.-F., Hansen, T. W., Asayama, K., Ohkubo, T., Jeppesen, J., et al. (2019) · JAMA · doi:10.1001/jama.2019.9811 · Cited by 491
Leung, A. A., Nerenberg, K., Daskalopoulou, S. S., McBrien, K., Zarnke, K. B., Dasgupta, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.066 · Cited by 461
Quinn, R. R., Hemmelgarn, B. R., Padwal, R. S., Myers, M. G., Cloutier, L., Bolli, P., McKay, D. W., Khan, N. A., Hill, M. D., Mahon, J., et al. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70378-0 · Cited by 346
Self-citationMyers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Self-citationMeasurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Self-citationRoerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Self-citationBlood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“Using AOBP devices may facilitate obtaining the average of multiple measurements during a visit.”
MethodInfluential(2022) · PubMed Central · doi:10.6515/acs.202205_38(3).20220321a · Cited by 117
Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement
Bhatt, H., Siddiqui, M., Judd, E., Oparil, S., & Calhoun, D. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.03.186 · Cited by 77
Egan, B. M., Laken, M. A., Donovan, J. L., & Woolson, R. F. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.151522 · Cited by 38
Office blood pressure measurement in the 21st century
Myers, M. G., Asmar, R., & Staessen, J. A. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13276 · Cited by 34
Self-citationRole of Aldosterone Blockade in Resistant Hypertension
Egan, B. M., & Li, J. (2014) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2014.04.004 · Cited by 33
Metadata
- Authors
- Myers, M. G., Valdivieso, M., & Kiss, A.
- Venue
- Journal of Hypertension
- Published
- 2009-02
- Volume
- 27
- Issue
- 2
- Pages
- 280-286
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2031151303
- Cited by
- 209
- References
- 24
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.