Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 254

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Continuous positive airway pressure treatment in sleep apnea patients with resistant hypertension: a randomized, controlled trial

Lozano, Lourdes, Tovar, José Luis, Sampol, Gabriel, Romero, Odile, Jurado, María José, Segarra, Alfons, Espinel, Eugènia, Ríos, José, Untoria, María Dolores, Lloberes, Patrícia · 2010 · Journal of Hypertension

Abstract

OBJECTIVES: This controlled trial assessed the effect of continuous positive airway pressure (CPAP) on blood pressure (BP) in patients with obstructive sleep apnea (OSA) and resistant hypertension (RH). METHODS: We evaluated 96 patients with resistant hypertension, defined as clinic BP at least 140/90 mmHg despite treatment with at least three drugs at adequate doses, including a diuretic. Patients underwent a polysomnography and a 24-h ambulatory BP monitoring (ABPM). They were classified as consulting room or ABPM-confirmed resistant hypertension, according to 24-h BP lower or higher than 125/80 mmHg. Patients with an apnea-hypopnea index at least 15 events/h (n = 75) were randomized to receive either CPAP added to conventional treatment (n = 38) or conventional medical treatment alone (n = 37). ABPM was repeated at 3 months. The main outcome was the change in systolic and diastolic BP. RESULTS: Sixty-four patients completed the follow-up. Patients with ABPM-confirmed resistant hypertension treated with CPAP (n = 20), unlike those treated with conventional treatment (n = 21), showed a decrease in 24-h diastolic BP (-4.9 ± 6.4 vs. 0.1 ± 7.3 mmHg, P = 0.027). Patients who used CPAP > 5.8 h showed a greater reduction in daytime diastolic BP {-6.12 mmHg [confidence interval (CI) -1.45; -10.82], P = 0.004}, 24-h diastolic BP (-6.98 mmHg [CI -1.86; -12.1], P = 0.009) and 24-h systolic BP (-9.71 mmHg [CI -0.20; -19.22], P = 0.046). The number of patients with a dipping pattern significantly increased in the CPAP group (51.7% vs. 24.1%, P = 0.008). CONCLUSION: In patients with resistant hypertension and OSA, CPAP treatment for 3 months achieves reductions in 24-h BP. This effect is seen in patients with ABPM-confirmed resistant hypertension who use CPAP more than 5.8 h.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e32833b9c63

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 254

Metadata

Authors
Lozano, L., Tovar, J. L., Sampol, G., Romero, O., Jurado, M. J., Segarra, A., Espinel, E., Ríos, J., Untoria, M. D., & Lloberes, P.
Venue
Journal of Hypertension
Published
2010-10
Volume
28
Issue
10
Pages
2161-2168
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1973005133
Cited by
254
References
39
FWCI
15.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.