Daily Electrode Change and Effect on Cardiac Monitor Alarms: An Evidence-Based Practice Approach
The DOI matches its Crossref record, with a small difference in title or year; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Frequent monitor alarms are distracting and interfere with clinicians performing critical tasks. This article describes a quality improvement rapid-cycle change approach to explore the benefits of changing electrodes daily on the number of cardiac monitor alarms. Eight days of baseline and intervention data were compared for 2 adult acute care units. Average alarms per bed per day were reduced by 46% on both units. Daily electrocardiogram electrode change reduces the number of cardiac monitor alarms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Noise levels in Johns Hopkins Hospital
Busch-Vishniac, I. J., West, J. E., Barnhill, C., Hunter, T., Orellana, D., & Chivukula, R. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.2118327 · Cited by 416
Xie, H., Kang, J., & Mills, G. H. (2009) · Critical Care · doi:10.1186/cc7154 · Cited by 315
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248 · cited 2×
“artifacts, can cause skin irritation and infection (13) • Ag/AgCl gel electrode when dried generates noise and artifact (11) • Electrodes affected by (11): ◦ Skin humidity; time of day; seasons; use of skin care products that cause changes”
BackgroundCharacterizing noise and perceived work environment in a neurological intensive care unit
Ryherd, E. E., Waye, K. P., & Ljungkvist, L. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2822661 · Cited by 192 · cited 2×
“Level V 13 A/B • Survey of biomedical technicians (most frequent electrode problems include) (6): ◦ Dried-up electrodes; old or bad electrodes; poor connectivity between patient”
BackgroundMarozas, V., Petrėnas, A., Daukantas, S., & Lukoševičius, A. (2011) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.12.004 · Cited by 141 · cited 1×
“electrode contact to skin (4, 15, 25) • Recommend electrodes be changed routinely (19); every 24 h (18, 20, 22-24) ◦ Good skin preparation (4,16,19); use sandpaper to rough skin up to promote electrode adhesion (21); shaving or clipping hair (25) ◦ Ensure electrodes are on flat, nonmuscular areas (4) ◦ Check for loose…”
BackgroundA study on electrode gels for skin conductance measurements
Tronstad, C., Johnsen, G. K., Grimnes, S., & Martinsen, Ø. G. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/10/008 · Cited by 93 · cited 1×
“Level II 3 A/B • Electrodes used beyond first day exhibit poor electrode-skin contact; inaccurate impedance measurement (10) • Factors causing electrodes to become disconnected (12): ◦ Patient movement; perspiration; manipulation; defective electrodes • Best performing electrodes (14): ◦ Good adhesive properties; low…”
BackgroundEquipment-related Electrocardiographic Artifacts
Patel, S., Souter, M. J., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296537.62905.25 · Cited by 90 · cited 1×
“electrode contact to skin (4, 15, 25) • Recommend electrodes be changed routinely (19); every 24 h (18, 20, 22-24) ◦ Good skin preparation (4,16,19); use sandpaper to rough skin up to promote electrode adhesion (21); shaving or clipping hair (25) ◦ Ensure electrodes are on flat, nonmuscular areas (4) ◦ Check for loose…”
BackgroundElectrocardiography Pitfalls and Artifacts: The 10 Commandments
Baranchuk, A., Shaw, C., Alanazi, H., Campbell, D., Bally, K., Redfearn, D. P., Simpson, C. S., & Abdollah, H. (2009) · Critical Care Nurse · doi:10.4037/ccn2009607 · Cited by 60 · cited 1×
“and electrode • Changing electrodes every 24 h (17): ◦ Is one way to decrease the risk of alarm fatigue and delayed alarm response;”
BackgroundReal-Time Management of Faulty Electrodes in Electrical Impedance Tomography
Hartinger, A. E., Guardo, R., Adler, A., & Gagnon, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003103 · Cited by 42
A comparison study of electrodes for neonate electrical impedance tomography
Rahal, M., Khor, J. M., Demosthenous, A., Tizzard, A., & Bayford, R. H. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/6/s05 · Cited by 36 · cited 1×
“electrode contact to skin (4, 15, 25) • Recommend electrodes be changed routinely (19); every 24 h (18, 20, 22-24) ◦ Good skin preparation (4,16,19); use sandpaper to rough skin up to promote electrode adhesion (21); shaving or clipping hair (25) ◦ Ensure electrodes are on flat, nonmuscular areas (4) ◦ Check for loose…”
BackgroundJohns Hopkins Nursing Evidence‐Based Practice: Model and Guidelines, 2nd Edition
Philbrick, V. M. (2012) · AORN Journal · doi:10.1016/j.aorn.2012.10.004 · Cited by 35
Biomedical Instrumentation Systems
Chatterjee, S., & Miller, A. (2010) · Cited by 11
Management of ECG Cables and Leadwires
Turkmen, A., & Pantiskas, C. (2011) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-45.2.130 · Cited by 3
Research works printed but not linked: 1
- 2011, Top 10 technology hazards for 2012., Health Dev, 40, 358
Cited by
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Drew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Self-citationSteinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
“Simply improving skin preparation with fine sandpaper and daily electrode replacement reduced alarms by 46% (Clochesy et al., 1991; Cvach et al., 2012; Pettersen et al., 2014).”
BackgroundPaine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
“Disposable electrocardiographic lead wires or daily electrode changes were evaluated in 3 studies:(32,33,38) 1 single intervention cluster-randomized trial(32) and 2 quasi-experimental studies.(33,38) In the clusterrandomized trial, disposable lead wires were compared to reusable lead wires, with disposable lead wires…”
Background
Metadata
- Authors
- Cvach, M. M., Biggs, M., Rothwell, K. J., & Charles-Hudson, C.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- Cvach, Maria M.
- ORCID
- Cvach, Maria M.
- Venue
- Journal of Nursing Care Quality
- Published
- 2013-07
- Volume
- 28
- Issue
- 3
- Pages
- 265-271
- ISSN
- 1057-3631 (ISSN-L)
- OpenAlex
- W2004000883
- Cited by
- 75
- References
- 13
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 3 · 2021: 6 · 2020: 5 · 2019: 4 · 2018: 14 · 2017: 13 · 2016: 6 · 2015: 6 · 2014: 3 · 2013: 4
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Nursing Care Quality (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- alarm reduction, rapid-cycle quality improvement, acute care units
- MeSH terms
- Coronary Care Units, Electrodes, Humans, Nursing Staff, Hospital, Evidence-Based Nursing, Clinical Alarms, Cardiovascular Nursing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.